49 resultados para scale-free rete reti invarianza scala simulazione repast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamically reconfigurable SRAM-based field-programmable gate arrays (FPGAs) enable the implementation of reconfigurable computing systems where several applications may be run simultaneously, sharing the available resources according to their own immediate functional requirements. To exclude malfunctioning due to faulty elements, the reliability of all FPGA resources must be guaranteed. Since resource allocation takes place asynchronously, an online structural test scheme is the only way of ensuring reliable system operation. On the other hand, this test scheme should not disturb the operation of the circuit, otherwise availability would be compromised. System performance is also influenced by the efficiency of the management strategies that must be able to dynamically allocate enough resources when requested by each application. As those resources are allocated and later released, many small free resource blocks are created, which are left unused due to performance and routing restrictions. To avoid wasting logic resources, the FPGA logic space must be defragmented regularly. This paper presents a non-intrusive active replication procedure that supports the proposed test methodology and the implementation of defragmentation strategies, assuring both the availability of resources and their perfect working condition, without disturbing system operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelação e simulação baseadas em agentes estão a ganhar cada vez mais importância e adeptos devido à sua flexibilidade e potencialidade em reproduzir comportamentos e estudar um sistema na perspetiva global ou das interações individuais. Neste trabalho, criou-se um sistema baseado em agentes e desenvolvido em Repast Simphony com o objectivo de analisar a difusão de um novo produto ou serviço através de uma rede de potenciais clientes, tentando compreender, assim, como ocorre e quanto tempo demora esta passagem de informação (inovação) com diversas topologias de rede, no contato direto entre pessoas. A simulação baseia-se no conceito da existencia de iniciadores, que são os primeiros consumidores a adotar um produto quando este chega ao mercado e os seguidores, que são os potenciais consumidores que, apesar de terem alguma predisposição para adotar um novo produto, normalmente só o fazem depois de terem sido sujeitos a algum tipo de influência. Com a aplicação criada, simularam-se diversas situações com a finalidade de obter e observar os resultados gerados a partir de definições iniciais diferentes. Com os resultados gerados pelas simulações foram criados gráficos representativos dos diversos cenários. A finalidade prática desta aplicação, poderá ser o seu uso em sala de aula para simulação de casos de estudo e utilização, em casos reais, como ferramenta de apoio à tomada de decisão, das empresas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para uma melhor avaliação e definição do plano de intervenção do indivíduo, é cada vez mais importante a existência instrumentos de avaliação válidos e fiáveis para a população portuguesa. Objetivo: Traduzir e adaptar para a população Portuguesa a escala Trunk Impairment Scale (TIS) em pacientes pós-AVE, e avaliar as propriedades psicométricas da mesma. Metodologia: A TIS foi traduzida para o Português e adaptada culturalmente para a população portuguesa. As propriedades psicométricas da mesma, incluindo validade, fiabilidade, concordância inter-observadores, consistência interna, sensibilidade, especificidade, poder de resposta, foram avaliadas numa população diagnosticada com AVE e num grupo de controlo de participantes saudáveis. Participaram neste estudo 80 indivíduos, divididos em dois grupos, nomeadamente indivíduos pós-AVE (40) e um grupo sem patologia (40). Os participantes foram submetidos à aplicação das escalas de Berg, Medida de Independência Funcional e Escala de Desempenho Físico Fugl Meyer e a TIS de modo a avaliar as propriedades psicométricas desta. As avaliações foram realizadas por duas fisioterapeutas experientes e o re-teste foi realizado após 48 horas. Os dados foram registados e trabalhados com o programa informático SPSS 21.0. Resultados: Relativamente aos valores obtidos, verificou-se que, quanto à consistência interna da TIS estes apresentam-se de forma moderada a elevada (alfa Cronbach = 0,909). Quanto à fiabilidade inter-observadores, os itens com menor valor são os itens 1 e 4 (0,759 e 0,527, respetivamente) e os itens com valor de Kappa mais alto são os itens 5 e 6 (0,830 e 0,893, respetivamente). Relativamente à validade de critério, verificou-se que não houve correlação entre a escala de Desempenho Físico Fugl-Meyer, a escala de Equilibrio de Berg e a Medida de Independência Funcional, ou seja, os valores obtidos r=0,166; r=0,017; r= -0,002, respetivamente. Quanto à validade de construção, constatou-se que o valor da mediana é mais elevado nos itens 1 a 5, logo sugere que haja diferenças entre o grupo de indivíduos pós-AVE e o grupo de indivíduos saudáveis (p<0,001). Entre os outros dois itens (6 e 7) não foram encontradas diferenças nas respostas nos dois grupos, sendo o valor de p > 0,001. Conclusão: Os resultados obtidos neste estudo sugerem que a versão portuguesa da TIS apresenta bons níveis de fiabilidade, consistência interna e também apresenta bons resultados no que refere à concordância inter-observadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of HRM perceptions is a growing interest in the literature, as one of the antecedents of HRM outcomes. Regardless, not only the cognitive aspect of perception is interesting in this field (what you think) but also the affective perspective is of interest (how you feel about it). In this study we propose a scale for assessing satisfaction with the perceptions of the HRM practices. A 24 item Likert-type scale was developed considering literature review, to assess subjects’ satisfaction with Human Resources Practices in a healthcare setting. Talked reflections were held and a survey encompassing all workers from a Hospital was conducted later, with a sample of 922 subjects. Exploratory and Confirmatory Factor Analysis were performed; reliability was tested using Cronbach’s alpha. The scale presents good psychometric properties with alpha values that range from .71 to .91. Exploratory and Confirmatory Factor Analysis demonstrated that the scale presents a very good fit with CFI= 0.94, AGFI= 0.88, and RMSEA= 0.07. The present study represents a first approach in the usage of this scale and despite having a large sample, respondents originate from a single institution. This study presents a pertinent scale towards measuring a seldom explored construct of the worker-organization relationship. The scale is parsimonious and results are promising. There seems to be very little research on how subjects feel about the HRM practices. This construct, very much in line with more recent studies concerning worker perceptions can be especially interesting in the context of the worker-organization relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This work aims at further developing and testing the psychometric properties of the Cultural Intelligence Scale (Ang & Van Dyne, 2006) in an Erasmus Mundus Students and Alumni Population, including reliability. Design Methodology: The study included 626 participants from 109 different countries that emcompasses 6 continents. Exploratory and Confirmatory Factor Analysis procedures were carried out in order to test the scale in a multicultural scale of Erasmus Mundus Students. Reliability was assessed using Cronbach Alpha. Results: The scale presents excellent psychometric properties with alpha values that range from .84 to .90. Exploratory and Confirmatory Factor Analyses demonstrated that the original model of the scale presents an exceptionally good fit. Limitations: The present study was conducted using a convenience sample and online questionnaires that limit its conclusions when we consider the globality of the Erasmus Mundus Students. Research/Practical Implications: This study presents evidence that Ang and Van Dyne’s scale is an adequate measure instrument to assess intercultural intelligence in a multicultural setting of students and alumni. Originality/Value: Multicultural samples and studies are becoming more and more present and relevant; the study of intercultural competences and habilities is becoming increasingly important, and in this task, solid psychometric instruments are of paramount importance. This study presents evidence that Ang and Van Dyne’s (2006) scale is a fairly recent and parsimonious instrument with excellent psychometric properties properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.