46 resultados para cross-language speaker recognition


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The English article system is actually so complex that it presents many challenges for most non-native learners of English. The main difficulty of Portuguese learners, despite the numerous similarities between the two article systems, is noticeable in a marked tendency to produce the definite article where native speakers of English would not use it. This article reports the results of a cross-sectional study which examined the English definite article overproduction by a group of 12 Portuguese EFL learners with at least seven years of English instruction. The prediction is that these learners will exhibit evidence of transferring L1 features to their interlanguage when they overuse the definite article. The data were collected by means of a gap-filling task and a composition. The results found, as predicted, that these learners overused the in generic contexts. It is argued that this overuse is directly tied to and can be explained by transfer to somewhere and conceptual transfer principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Patient-centredness has become an important aspect of health service delivery; however, there are a limited number of studies that focus on this concept in the domain of hearing healthcare. The objective of this study was to examine and compare audiologists’ preferences for patient-centredness in Portugal, India and Iran. Design The study used a cross-sectional survey design with audiologists recruited from three different countries. Participants A total of 191 fully-completed responses were included in the analysis (55 from Portugal, 78 from India and 58 from Iran). Main outcome measure The Patient–Practitioner Orientation Scale (PPOS). Results PPOS mean scores suggest that audiologists have a preference for patient-centredness (ie, mean of 3.6 in a 5-point scale). However, marked differences were observed between specific PPOS items suggesting these preferences vary across clinical situations. A significant level of difference (p<0.001) was found between audiologists’ preferences for patient-centredness in three countries. Audiologists in Portugal had a greater preference for patient-centredness when compared to audiologists in India and Iran, although no significant differences were found in terms of age and duration of experience among these sample populations. Conclusions There are differences and similarities in audiologists’ preferences for patient-centredness among countries. These findings may have implications for the training of professionals and also for clinical practice in terms of optimising hearing healthcare across countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The aim of this study was to determine tympanometric values of children who attend Oporto daycare centers and further analyze any relations with host and environmental factors. Methods Cross sectional study in a randomly selected sample of 117 daycare children up-to 3-years old from Oporto. Tympanometric measures were collected. Results Children presented in left ear (LE) a mean peak pressure (PP) of −156.53 daPa and a mean compliance of 0.16 cm3. Right ear (RE) revealed a PP of −145.61 daPa and a compliance of 0.19 cm3. Normal tympanograms (type A) had a lower frequency than abnormal tympanograms (type B and type C). There was a positive association between age and compliance (LE: p = 0.016; RE: p = 0.013) and between the presence of rhinorrhea and PP (LE: p = 0.002; RE: p < 0.05). Abnormal tympanograms were more frequent in Spring (RE: p = 0.009), in younger children (LE: p = 0.03) and in children that had rhinorrhea (LE: p = 0.002; RE: p = 0.044). Healthy children had a mean PP of −125.19 daPa and a mean compliance of 0.21 cm3 in LE and a mean PP of −144.27 daPa and a mean compliance of 0.22 cm3 in RE. Conclusion Tympanometric measures presented in this paper may be applicable to Oporto daycare children up-to 3 years-old. Most of daycare children revealed abnormal tympanograms. Age, rhinorrhea and season influenced children's middle-ear condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Societal changes have, throughout history, pushed the long-established boundaries of education across all grade levels. Technology and media merge with education in a continuous complex social process with human consequences and effects. We, teachers, can aspire to understand and interpret this volatile context that is being redesigned at the same time society itself is being reshaped as a result of the technological evolution. The language- learning classroom is not impenetrable to these transformations. Rather, it can perhaps be seen as a playground where teachers and students gather to combine the past and the present in an integrated approach. We draw on the results from a previous study and argue that Digital Storytelling as a Process is capable of aggregating and fostering positive student development in general, as well as enhancing interpersonal relationships and self-knowledge while improving digital literacy. Additionally, we establish a link between the four basic language-learning skills and the Digital Storytelling process and demonstrate how these converge into what can be labeled as an integrated language learning approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O projeto tem como objetivo desenvolver e avaliar um modelo que facilita o acesso para pessoas surdas ou com deficiência auditiva, o acesso ao conteúdo digital - em particular o conteúdo educacional e objetos de aprendizagem – a criação de condições para uma maior inclusão social de surdos e deficientes auditivos. Pretende-se criar um modelo bidirecional, em que permite a pessoas com deficiências auditivas, possam se comunicar com outras pessoas, com a tradução da Língua Gestual Portuguesa (LGP) para a Língua Portuguesa (LP) e que outras pessoas não portadoras de qualquer deficiência auditiva possam por sua vez comunicar com os surdos ou deficientes auditivos através da tradução da LP para a LGP. Há um conjunto de técnicas que poderíamos nos apoiar para desenvolver o modelo e implementar a API de tradução da LGP em LP. Muitos estudos são feitos com base nos modelos escondidos de Markov (HMM) para efetuar o reconhecimento. Recentemente os estudos estão a caminhar para o uso de técnicas como o “Dynamic Time Warping” (DTW), que tem tido mais sucesso do que outras técnicas em termos de performance e de precisão. Neste projeto optamos por desenvolver a API e o Modelo, com base na técnica de aprendizagem Support Vector Machines (SVM) por ser uma técnica simples de implementar e com bons resultados demonstrados em reconhecimento de padrões. Os resultados obtidos utilizando esta técnica de aprendizagem foram bastante ótimos, como iremos descrever no decorrer do capítulo 4, mesmo sabendo que utilizamos dois dispositivos para capturar dados de descrição de cada gesto. Toda esta tese integra-se no âmbito do projeto científico/ investigação a decorrer no grupo de investigação GILT, sob a coordenação da professora Paula Escudeiro e suportado pela Fundação para Ciência e Tecnologia (FCT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The process of Competences Recognition, Validation and Certification , also known as Accreditation of Prior Learning (APL), is an innovative means of attaining school certificates for individuals without an academic background. The main objective of this process is to validate what people have learned in informal contexts, in order to attribute academic certificates. With the increasing interest of the qualification of workers and governmental support, more and more Portuguese organizations promote this process within their facilities and their work hours. This study explores the relationship between the promotion of this Human Resource Development Programme and employee’s attitudes (Job Satisfaction and Organizational Commitment) and behaviours (Extra-role Organizational Citizenship Behaviours) towards the organization they work for. Results of a cross-sectional survey of Portuguese Industrial Workers (N=135) showed that statistical significant results are in the higher levels of Voice Behaviours (a dimension of Extra-role Organizational Citizenship Behaviour in the groups of workers who were involved or had graduated from the firm promoted APL process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster presented in The 28th GI/ITG International Conference on Architecture of Computing Systems (ARCS 2015). 24 to 26, Mar, 2015. Porto, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intelligent wheelchairs (IW) are technologies that can increase the autonomy and independence of elderly people and patients suffering from some kind of disability. Nowadays the intelligent wheelchairs and the human-machine studies are very active research areas. This paper presents a methodology and a Data Analysis System (DAS) that provides an adapted command language to an user of the IW. This command language is a set of input sequences that can be created using inputs from an input device or a combination of the inputs available in a multimodal interface. The results show that there are statistical evidences to affirm that the mean of the evaluation of the DAS generated command language is higher than the mean of the evaluation of the command language recommended by the health specialist (p value = 0.002) with a sample of 11 cerebral palsy users. This work demonstrates that it is possible to adapt an intelligent wheelchair interface to the user even when the users present heterogeneous and severe physical constraints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real-time monitoring applications may be used in a wireless sensor network (WSN) and may generate packet flows with strict quality of service requirements in terms of delay, jitter, or packet loss. When strict delays are imposed from source to destination, the packets must be delivered at the destination within an end-to-end delay (EED) hard limit in order to be considered useful. Since the WSN nodes are scarce both in processing and energy resources, it is desirable that they only transport useful data, as this contributes to enhance the overall network performance and to improve energy efficiency. In this paper, we propose a novel cross-layer admission control (CLAC) mechanism to enhance the network performance and increase energy efficiency of a WSN, by avoiding the transmission of potentially useless packets. The CLAC mechanism uses an estimation technique to preview packets EED, and decides to forward a packet only if it is expected to meet the EED deadline defined by the application, dropping it otherwise. The results obtained show that CLAC enhances the network performance by increasing the useful packet delivery ratio in high network loads and improves the energy efficiency in every network load.