29 resultados para techniques: image processing


Relevância:

80.00% 80.00%

Publicador:

Resumo:

PTDC/EME–TME/66207/2006 e POSC/EEA-SRI/55386/2004

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Drilling of carbon fibre/epoxy laminates is usually carried out using standard drills. However, it is necessary to adapt the processes and/or tooling as the risk of delamination, or other damages, is high. These problems can affect mechanical properties of produced parts, therefore, lower reliability. In this paper, four different drills – three commercial and a special step (prototype) – are compared in terms of thrust force during drilling and delamination. In order to evaluate damage, enhanced radiography is applied. The resulting images were then computational processed using a previously developed image processing and analysis platform. Results show that the prototype drill had encouraging results in terms of maximum thrust force and delamination reduction. Furthermore, it is possible to state that a correct choice of drill geometry, particularly the use of a pilot hole, a conservative cutting speed – 53 m/min – and a low feed rate – 0.025 mm/rev – can help to prevent delamination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The characteristics of carbon fibre reinforced laminates have widened their use from aerospace to domestic appliances, and new possibilities for their usage emerge almost daily. In many of the possible applications, the laminates need to be drilled for assembly purposes. It is known that a drilling process that reduces the drill thrust force can decrease the risk of delamination. In this work, damage assessment methods based on data extracted from radiographic images are compared and correlated with mechanical test results—bearing test and delamination onset test—and analytical models. The results demonstrate the importance of an adequate selection of drilling tools and machining parameters to extend the life cycle of these laminates as a consequence of enhanced reliability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Engenharia de Computação e Instrumentação Médica

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste documento ´e feita a descrição detalhada da integração modular de um script no software OsiriX. O objectivo deste script ´e determinar o diâmetro central da artéria aorta a partir de uma Tomografia Computorizada. Para tal são abordados conceitos relacionados com a temática do processamento de imagem digital, tecnologias associadas, e.g., a norma DICOM e desenvolvimento de software. Como estudo preliminar, são analisados diversos visualizadores de imagens médica, utilizados para investigação ou mesmo comercializados. Foram realizadas duas implementações distintas do plugin. A primeira versão do plugin faz a invocação do script de processamento usando o ficheiro de estudo armazenado em disco; a segunda versão faz a passagem de dados através de um bloco de memória partilhada e utiliza o framework Java Native Interface. Por fim, é demonstrado todo o processo de aposição da Marcação CE de um dispositivo médico de classe IIa e obtenção da declaração de conformidade por parte de um Organismo Notificado. Utilizaram-se os Sistemas Operativos Mac OS X e Linux e as linguagens de programação Java, Objective-C e Python.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We are presenting a simple, low-cost and rapid solid-state optical probe for screening chlorpromazine (CPZ) in aquacultures. The method exploits the colourimetric reaction between CPZ and Fe(III) ion that occurs at a solid/liquid interface, the solid layer consisting of ferric iron entrapped in a layer of plasticized PVC. If solutions containing CPZ are dropped onto such a layer, a colour change occurs from light yellow to dark pink or even light blue, depending on the concentration of CPZ. Visual inspection enables the concentration of CPZ to be estimated. The resulting colouration was also monitored by digital image collection for a more accurate quantification. The three coordinates of the hue, saturation and lightness system were obtained by standard image processing along with mathematical data treatment. The parameters affecting colour were assessed and optimized. Studies were conducted by visible spectrophotometry and digital image acquisition, respectively. The response of the optimized probe towards the concentration of CPZ was tested for several mathematical transformations of the colour coordinates, and a linear relation was found for the sum of hue and luminosity. The limit of detection is 50 μM (corresponding to about 16 μg per mL). The probe enables quick screening for CPZ in real water samples with prior sample treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

in RoboCup 2007: Robot Soccer World Cup XI

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is well-known that ROVs require human intervention to guarantee the success of their assignment, as well as the equipment safety. However, as its teleoperation is quite complex to perform, there is a need for assisted teleoperation. This study aims to take on this challenge by developing vision-based assisted teleoperation maneuvers, since a standard camera is present in any ROV. The proposed approach is a visual servoing solution, that allows the user to select between several standard image processing methods and is applied to a 3-DOF ROV. The most interesting characteristic of the presented system is the exclusive use of the camera data to improve the teleoperation of an underactuated ROV. It is demonstrated through the comparison and evaluation of standard implementations of different vision methods and the execution of simple maneuvers to acquire experimental results, that the teleoperation of a small ROV can be drastically improved without the need to install additional sensors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

13th International Conference on Autonomous Robot Systems (Robotica), 2013

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The process of visually exploring underwater environments is still a complex problem. Underwater vision systems require complementary means of sensor information to help overcome water disturbances. This work proposes the development of calibration methods for a structured light based system consisting on a camera and a laser with a line beam. Two different calibration procedures that require only two images from different viewpoints were developed and tested in dry and underwater environments. Results obtained show, an accurate calibration for the camera/projector pair with errors close to 1 mm even in the presence of a small stereos baseline.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O controlo da qualidade em ressonância magnética (RM) passa pela realização de diversos testes ao equipamento e calibrações diárias, onde os fantomas desempenham um papel fundamental. Este trabalho teve como objetivo principal o desenvolvimento de um fantoma cerebral para um sistema de RM de intensidade 3.0 Tesla. Com base na literatura existente, escolheram-se como reagentes o cloreto de gadolínio (III) (GdCl3), a agarose, e o gelificante carragena, tendo sido ainda acrescentado o conservante químico azida de sódio (NaN3) de forma a inibir a degradação da solução. Realizaram-se vários testes com diferentes concentrações dos materiais selecionados até obter as misturas adequadas a suscetibilidade magnética das substâncias branca e cinzenta cerebrais. Os tempos de relaxação T1 das diversas substâncias desenvolvidas foram medidos, apresentando o fantoma final uns tempos de T1 de 702±10 ms, quando a concentração de GdCl3 foi de 100 µmol (substância branca) e 1179±23 ms quando a concentração foi de 15 µmol (substância cinzenta). Os valores de T1 do fantoma foram comparados estatisticamente com os tempos de relaxação conseguidos a partir de um cérebro humano, obtendo-se uma correlação de 0.867 com significância estatística. No intuito de demonstrar a aplicabilidade do fantoma, este foi sujeito a um protocolo de RM, do qual constaram as sequências habitualmente usadas no estudo cerebral. Como principais resultados constatou-se que, nas sequências ponderadas em T1, o fantoma apresenta uma forte associação positiva (rs > 0.700 p = 0.072) com o cérebro de referência, ainda que não sejam estatisticamente significativos. As sequências ponderadas em T2 demonstraram uma correlação positiva moderada e fraca, sendo a ponderação densidade protónica a única a apresentar uma associação negativa. Desta forma, o fantoma revelou-se um ótimo substituto do cérebro humano. Este trabalho culminou na criação de um modelo cerebral tridimensional onde foram individualizadas as regiões das substâncias branca e cinzenta, de forma a posteriormente serem preenchidas pelas correspondentes substâncias desenvolvidas, obtendo-se um fantoma cerebral antropomórfico.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O ensaio de dureza, e mais concretamente o ensaio de micro dureza Vickers, é no universo dos ensaios mecânicos um dos mais utilizados quer seja na indústria, no ensino ou na investigação e desenvolvimento de produto no âmbito das ciências dos materiais. Na grande maioria dos casos, a utilização deste ensaio tem como principal aplicação a caracterização ou controlo da qualidade de fabrico de materiais metálicos. Sendo um ensaio de relativa simplicidade de execução, rapidez e com resultados comparáveis e relacionáveis a outras grandezas físicas das propriedades dos materiais. Contudo, e tratando-se de um método de ensaio cuja intervenção humana é importante, na medição da indentação gerada por penetração mecânica através de um sistema ótico, não deixa de exibir algumas debilidades que daí advêm, como sendo o treino dos técnicos e respetivas acuidades visuais, fenómenos de fadiga visual que afetam os resultados ao longo de um turno de trabalho; ora estes fenómenos afetam a repetibilidade e reprodutibilidade dos resultados obtidos no ensaio. O CINFU possui um micro durómetro Vickers, cuja realização dos ensaios depende de um técnico treinado para a execução do mesmo, apresentando todas as debilidades já mencionadas e que o tornou elegível para o estudo e aplicação de uma solução alternativa. Assim, esta dissertação apresenta o desenvolvimento de uma solução alternativa ao método ótico convencional na medição de micro dureza Vickers. Utilizando programação em LabVIEW da National Instruments, juntamente com as ferramentas de visão computacional (NI Vision), o programa começa por solicitar ao técnico a seleção da câmara para aquisição da imagem digital acoplada ao micro durómetro, seleção do método de ensaio (Força de ensaio); posteriormente o programa efetua o tratamento da imagem (aplicação de filtros para eliminação do ruído de fundo da imagem original), segue-se, por indicação do operador, a zona de interesse (ROI) e por sua vez são identificadas automaticamente os vértices da calote e respetivas distâncias das diagonais geradas concluindo, após aceitação das mesmas, com o respetivo cálculo de micro dureza resultante. Para validação dos resultados foram utilizados blocos-padrão de dureza certificada (CRM), cujos resultados foram satisfatórios, tendo-se obtido um elevado nível de exatidão nas medições efetuadas. Por fim, desenvolveu-se uma folha de cálculo em Excel com a determinação da incerteza associada às medições de micro dureza Vickers. Foram então comparados os resultados nas duas metodologias possíveis, pelo método ótico convencional e pela utilização das ferramentas de visão computacional, tendo-se obtido bons resultados com a solução proposta.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nesta dissertação é apresentado um estudo dos sistemas de processamento automático de imagem em contexto de um problema relacionado com a individualização de neurónios em imagens da nematoda C. elegans durante estudos relacionados com a doença de Parkinson. Apresenta-se uma breve introdução à anatomia do verme, uma introdução à doença de Parkinson e uso do C. elegans em estudos relacionados e também é feita a análise de artigos em contexto de processamento de imagem para contextualizar a situação atual de soluções para o problema de extração de características e regiões específicas. Neste projeto é desenvolvida uma pipeline com o auxilio do software CellProfiler para procurar uma resposta para o problema em questão.