37 resultados para structural quality indicator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As indústrias de componentes e acessórios automóveis são um elo fundamental no processo produtivo da indústria automóvel. Neste leque industrial encontra-se a Preh Portugal, Lda, como empresa fornecedora de componentes electrónicos, mais concretamente, painéis de controlo de climatização. Os painéis fornecidos pela Preh aos seus clientes encontram-se sujeitos a rigorosos testes de qualidade e funcionalidade. Neste sentido o teste funcional das teclas surge, relacionando o curso da tecla em função de uma força actuante. Esta relação está comprometida com uma curva característica padrão para o tipo de tecla. Para além destes compromissos, também é necessário que a tecla feche e abra o seu contacto eléctrico. Esta tese foca-se no desenvolvimento do teste de teclas, apresentando uma alteração ao sistema actual com a introdução de um sistema embebido, no intuito de flexibilizar o sistema de teste e reduzindo custos. O sistema embebido pretende dar capacidade de processamento ao teste e, desta forma, substituir o actual computador como elemento de processamento. A solução implementada consistiu numa mudança estrutural, através da inclusão do sistema embebido entre o computador e o sistema de deslocamento. Passando o foco central do processo de teste a residir no sistema embebido, este tem de estabelecer comunicações com os restantes elementos intervenientes no teste. Estabelece comunicações série RS-232 com o sistema de deslocamento (leitura do curso e força na tecla), Ethernet com o computador (comandos, parâmetros e resultados) e CAN com o painel de controlo de climatização (fecho/abertura do contacto eléctrico). A concretização deste projecto resultou numa nova estrutura e aplicação, a qual é facilmente integrada na linha de produção com as vantagens de ser menos onerosa e mais flexível, conforme o pretendido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apesar da enorme evolução tecnológica, os prazos na construção são cada vez mais reduzidos e os custos mais controlados, verificando-se uma despreocupação no que diz respeito a aspetos como a qualidade e durabilidade da construção das estruturas. Desperta assim nos técnicos, donos-de-obra, entidades executantes e projetistas a necessidade de avaliar o estado de conservação das estruturas de betão armado. Esta dissertação tem como objetivo principal abordar as anomalias e os mecanismos de deterioração mais correntes, os métodos de ensaio destrutivos ou parcialmente destrutivos mais utilizados e adequados, e abordar algumas das técnicas de reparação e reforço das estruturas de betão armado. Os principais danos apresentados nas estruturas são devidos a agentes físicos, mecânicos, biológicos e químicos. Podem ser devidos a causas diretas (acidentais ou naturais), que acarretam uma ação concreta sobre os elementos estruturais, e causas indiretas (humanas), diretamente ligadas com erros de projeto. É primordial fazer-se o levantamento de todas as anomalias existentes para se recorrer a um método de inspeção e ensaio. Consoante a necessidade de informação e estado da estrutura são selecionados os ensaios a realizar, podendo ser realizados “in situ” ou em laboratório. As técnicas de reparação e reforço são vistas como métodos para melhorar as condições da estrutura ao nível da segurança, desempenho, habitabilidade e durabilidade, prevenindo a evolução dos mecanismos de deterioração.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este relatório de estágio aborda as principais tecnologias de construção utilizadas e as metodologias de gestão implementadas na empreitada de “Ampliação do Cais do Terminal XXI - Terminal de Contentores de Sines”. Com o objectivo de fazer enquadramento desta empreitada é apresentado ainda um levantamento das soluções estruturais e processos construtivos mais utilizados, com base nas obras mais relevantes de construção de cais acostáveis de navios em Portugal e em Cabo Verde, recentemente construídas ou ainda em construção. Relativamente à obra em estudo foram analisados em detalhe os processos construtivos, associados a cada uma das actividades, e sistemas de gestão implementados no âmbito do prazo, custos, qualidade, ambiente, segurança e saúde e ainda da exploração dos navios. São ainda descritos os principais conhecimentos adquiridos com o acompanhamento desta obra, decorrentes de dificuldades ocorridas e boas práticas implementadas. As principais fontes de informação, que serviram de base à elaboração deste relatório, foram os projectos, caderno de encargos e documentos gerados em obra, sendo alguns destes documentos de obra elaborados pelo próprio autor. Por fim regista-se a enorme utilidade que este relatório trouxe para o autor, que desta forma registou e sistematizou os conhecimentos adquiridos durante a obra, e espera-se que seja uma boa referência para os engenheiros civis em geral no planeamento e gestão de futuras obras portuárias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TiO2 nanorod films have been deposited on ITO substrates by dc reactive magnetron sputtering technique. The structures of these nanorod films were modified by the variation of the oxygen pressure during the sputtering process. Although all these TiO2 nanorod films deposited at different oxygen pressures show an anatase structure, the orientation of the nanorod films varies with the oxygen pressure. Only a very weak (101) diffraction peak can be observed for the TiO2 nanorod film prepared at low oxygen pressure. However, as the oxygen pressure is increased, the (220) diffraction peak appears and the intensity of this diffraction peak is increased with the oxygen pressure. The results of the SEM show that these TiO2 nanorods are perpendicular to the ITO substrate. At low oxygen pressure, these sputtered TiO2 nanorods stick together and have a dense structure. As the oxygen pressure is increased, these sputtered TiO2 nanorods get separated gradually and have a porous structure. The optical transmittance of these TiO2 nanorod films has been measured and then fitted by OJL model. The porosities of the TiO2 nanorod films have been calculated. The TiO2 nanorod film prepared at high oxygen pressure shows a high porosity. The dye-sensitized solar cells (DSSCs) have been assembled using these TiO2 nanorod films prepared at different oxygen pressures as photoelectrode. The optimum performance was achieved for the DSSC using the TiO2 nanorod film with the highest (220) diffraction peak and the highest porosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the joint effects of home environment and center-based child care quality on children’s language, communication, and early literacy development, while also considering prior developmental level. Participants were 95 children (46 boys), assessed as toddlers (mean age = 26.33 months;Time 1) and preschoolers (mean age = 68.71 months; Time 2) and their families. At both times, children attended center-based child care classrooms in the metropolitan area of Porto, Portugal. Results from hierarchical linear models indicated that home environment and preschool quality, but not center-based toddler child care quality, were associated with children’s language and literacy outcomes at Time 2. Moreover, the quality of preschool classrooms moderated the association between home environment quality and children’s language and early literacy skills – but not communication skills – at Time 2, suggesting the positive cumulative effects of home environment and preschool quality. Findings further support the existence of a detrimental effect of low preschool quality on children’s language and early literacy outcomes: positive associations among home environment quality and children’s developmental outcomes were found to reduce substantially when children attended low-quality preschool classrooms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dc magnetron sputtering-based method to grow high-quality Cu2ZnSnS4 (CZTS) thin films, to be used as an absorber layer in solar cells, is being developed. This method combines dc sputtering of metallic precursors with sulfurization in S vapour and with post-growth KCN treatment for removal of possible undesired Cu2−xS phases. In this work, we report the results of a study of the effects of changing the precursors’ deposition order on the final CZTS films’ morphological and structural properties. The effect of KCN treatment on the optical properties was also analysed through diffuse reflectance measurements. Morphological, compositional and structural analyses of the various stages of the growth have been performed using stylus profilometry, SEM/EDS analysis, XRD and Raman Spectroscopy. Diffuse reflectance studies have been done in order to estimate the band gap energy of the CZTS films. We tested two different deposition orders for the copper precursor, namely Mo/Zn/Cu/Sn and Mo/Zn/Sn/Cu. The stylus profilometry analysis shows high average surface roughness in the ranges 300–550 nm and 230–250 nm before and after KCN treatment, respectively. All XRD spectra show preferential growth orientation along (1 1 2) at 28.45◦. Raman spectroscopy shows main peaks at 338 cm−1 and 287 cm−1 which are attributed to Cu2ZnSnS4. These measurements also confirm the effectiveness of KCN treatment in removing Cu2−xS phases. From the analysis of the diffuse reflectance measurements the band gap energy for both precursors’ sequences is estimated to be close to 1.43 eV. The KCN-treated films show a better defined absorption edge; however, the band gap values are not significantly affected. Hot point probe measurements confirmed that CZTS had p-type semiconductor behaviour and C–V analysis was used to estimate the majority carrier density giving a value of 3.3 × 1018 cm−3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cu2ZnSnS4 is a promising semiconductor to be used as absorber in thin film solar cells. In this work, we investigated optical and structural properties of Cu2ZnSnS4 thin films grown by sulphurization of metallic precursors deposited on soda lime glass substrates. The crystalline phases were studied by X-ray diffraction measurements showing the presence of only the Cu2ZnSnS4 phase. The studied films were copper poor and zinc rich as shown by inductively coupled plasma mass spectroscopy. Scanning electron microscopy revealed a good crystallinity and compactness. An absorption coefficient varying between 3 and 4×104cm−1 was measured in the energy range between 1.75 and 3.5 eV. The band gap energy was estimated in 1.51 eV. Photoluminescence spectroscopy showed an asymmetric broad band emission. The dependence of this emission on the excitation power and temperature was investigated and compared to the predictions of the donor-acceptor-type transitions and radiative recombinations in the model of potential fluctuations. Experimental evidence was found to ascribe the observed emission to radiative transitions involving tail states created by potential fluctuations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Component joining is typically performed by welding, fastening, or adhesive-bonding. For bonded aerospace applications, adhesives must withstand high-temperatures (200°C or above, depending on the application), which implies their mechanical characterization under identical conditions. The extended finite element method (XFEM) is an enhancement of the finite element method (FEM) that can be used for the strength prediction of bonded structures. This work proposes and validates damage laws for a thin layer of an epoxy adhesive at room temperature (RT), 100, 150, and 200°C using the XFEM. The fracture toughness (G Ic ) and maximum load ( ); in pure tensile loading were defined by testing double-cantilever beam (DCB) and bulk tensile specimens, respectively, which permitted building the damage laws for each temperature. The bulk test results revealed that decreased gradually with the temperature. On the other hand, the value of G Ic of the adhesive, extracted from the DCB data, was shown to be relatively insensitive to temperature up to the glass transition temperature (T g ), while above T g (at 200°C) a great reduction took place. The output of the DCB numerical simulations for the various temperatures showed a good agreement with the experimental results, which validated the obtained data for strength prediction of bonded joints in tension. By the obtained results, the XFEM proved to be an alternative for the accurate strength prediction of bonded structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The TEM family of enzymes has had a crucial impact on the pharmaceutical industry due to their important role in antibiotic resistance. Even with the latest technologies in structural biology and genomics, no 3D structure of a TEM- 1/antibiotic complex is known previous to acylation. Therefore, the comprehension of their capability in acylate antibiotics is based on the protein macromolecular structure uncomplexed. In this work, molecular docking, molecular dynamic simulations, and relative free energy calculations were applied in order to get a comprehensive and thorough analysis of TEM-1/ampicillin and TEM-1/amoxicillin complexes. We described the complexes and analyzed the effect of ligand binding on the overall structure. We clearly demonstrate that the key residues involved in the stability of the ligand (hot-spots) vary with the nature of the ligand. Structural effects such as (i) the distances between interfacial residues (Ser70−Oγ and Lys73−Nζ, Lys73−Nζ and Ser130−Oγ, and Ser70−Oγ−Ser130−Oγ), (ii) side chain rotamer variation (Tyr105 and Glu240), and (iii) the presence of conserved waters can be also influenced by ligand binding. This study supports the hypothesis that TEM-1 suffers structural modifications upon ligand binding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stringent cost and energy constraints impose the use of low-cost and low-power radio transceivers in large-scale wireless sensor networks (WSNs). This fact, together with the harsh characteristics of the physical environment, requires a rigorous WSN design. Mechanisms for WSN deployment and topology control, MAC and routing, resource and mobility management, greatly depend on reliable link quality estimators (LQEs). This paper describes the RadiaLE framework, which enables the experimental assessment, design and optimization of LQEs. RadiaLE comprises (i) the hardware components of the WSN testbed and (ii) a software tool for setting-up and controlling the experiments, automating link measurements gathering through packets-statistics collection, and analyzing the collected data, allowing for LQEs evaluation. We also propose a methodology that allows (i) to properly set different types of links and different types of traffic, (ii) to collect rich link measurements, and (iii) to validate LQEs using a holistic and unified approach. To demonstrate the validity and usefulness of RadiaLE, we present two case studies: the characterization of low-power links and a comparison between six representative LQEs. We also extend the second study for evaluating the accuracy of the TOSSIM 2 channel model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radio link quality estimation in Wireless Sensor Networks (WSNs) has a fundamental impact on the network performance and also affects the design of higher-layer protocols. Therefore, for about a decade, it has been attracting a vast array of research works. Reported works on link quality estimation are typically based on different assumptions, consider different scenarios, and provide radically different (and sometimes contradictory) results. This article provides a comprehensive survey on related literature, covering the characteristics of low-power links, the fundamental concepts of link quality estimation in WSNs, a taxonomy of existing link quality estimators, and their performance analysis. To the best of our knowledge, this is the first survey tackling in detail link quality estimation in WSNs. We believe our efforts will serve as a reference to orient researchers and system designers in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliability of communications is key to expand application domains for sensor networks. SinceWireless Sensor Networks (WSN) operate in the license-free Industrial Scientific and Medical (ISM) bands and hence share the spectrum with other wireless technologies, addressing interference is an important challenge. In order to minimize its effect, nodes can dynamically adapt radio resources provided information about current spectrum usage is available. We present a new channel quality metric, based on availability of the channel over time, which meaningfully quantifies spectrum usage. We discuss the optimum scanning time for capturing the channel condition while maintaining energy-efficiency. Using data collected from a number of Wi-Fi networks operating in a library building, we show that our metric has strong correlation with the Packet Reception Rate (PRR). This suggests that quantifying interference in the channel can help in adapting resources for better reliability. We present a discussion of the usage of our metric for various resource allocation and adaptation strategies.