115 resultados para selective control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Control Centre operators are essential to assure a good performance of Power Systems. Operators’ actions are critical in dealing with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in incident analysis and diagnosis, and service restoration of Power Systems, offering context awareness and an easy integration in the working environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A acetilcolina (ACh) é o neurotransmissor mais importante no controlo da motilidade gastrointestinal. A libertação de ACh dos neurónios entéricos é regulada por receptores neuronais específicos (De Man et al., 2003). Estudos prévios demonstraram que a adenosina exerce um papel duplo na libertação de ACh dos neurónios entéricos através da activação dos receptores inibitórios A1 e facilitatórios A2A (Duarte-Araújo et al., 2004). O potencial terapêutico dos compostos relacionados com a adenosina no controlo da motilidade e da inflamação intestinal, levou-nos a investigar o papel dos receptores com baixa afinidade para a adenosina, A2B e A3, na libertação de acetilcolina induzida por estimulação eléctrica nos neurónios mioentéricos. Estudos de imunolocalização mostraram que os receptores A2B exibem um padrão de distribuição semelhante ao do marcador de células gliais (GFAP). No que respeita aos receptores A1 e A3, estes encontram-se distribuídos principalmente nos corpos celulares dos neurónios ganglionares mioentéricos, enquanto os receptores A2A estão localizados predominantemente nos terminais nervosos colinérgicos. Neste trabalho mostrou-se que a modulação da libertação de ACh-[3H] (usando os antagonistas selectivos DPCPX, ZM241385 e MRS1191) é balanceada através da activação tónica dos receptores inibitórios (A1) e facilitatórios (A2A e A3) pela adenosina endógena. O antagonista selectivo dos receptores A2B, PSB603, não foi capaz de modificar o efeito inibitório da NECA (análogo da adenosina com afinidade para receptores A2). O efeito facilitatório do agonista dos receptores A3, 2-Cl-IB MECA (1-10 nM), foi atenuado pelo MRS1191 e pelo ZM241385, os quais bloqueiam respectivamente os receptores A3 e A2A. Contrariamente à 2-Cl-IB MECA, a activação dos receptores A2A pelo CGS21680C, atenuou a facilitação da libertação de ACh induzida pela activação dos receptores nicotínicos numa situação em que a geração do potencial de acção neuronal foi bloqueada pela tetrodotoxina. A localização diferencial dos receptores excitatórios A3 e A2A ao longo dos neurónios mioentéricos explica porque razão a estimulação dos receptores A3 (com 2-Cl-IB MECA) localizados nos corpos celulares dos neurónios mioentéricos exerce um efeito sinérgico com os receptores facilitatórios A2A dos terminais nervosos no sentido de aumentarem a libertação de ACh. Os resultados apresentados consolidam e expandem a compreensão actual da distribuição e função dos receptores da adenosina no plexo mioentérico do íleo de rato, e devem ser tidos em consideração para a interpretação de dados relativos às implicações fisiopatológicas da adenosina nos transtornos da motilidade intestinal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the initial stage of this work, two potentiometric methods were used to determine the salt (sodium chloride) content in bread and dough samples from several cities in the north of Portugal. A reference method (potentiometric precipitation titration) and a newly developed ion-selective chloride electrode (ISE) were applied. Both methods determine the sodium chloride content through the quantification of chloride. To evaluate the accuracy of the ISE, bread and respective dough samples were analyzed by both methods. Statistical analysis (0.05 significance level) indicated that the results of these methods did not differ significantly. Therefore the ISE is an adequate alternative for the determination of chloride in the analyzed samples. To compare the results of these chloride-based methods with a sodium-based method, sodium was quantified in the same samples by a reference method (atomic absorption spectrometry). Significant differences between the results were verified. In several cases the sodium chloride content exceeded the legal limit when the chloride-based methods were used, but when the sodium-based method was applied this was not the case. This could lead to the erroneous application of fines and therefore the authorities should supply additional information regarding the analytical procedure for this particular control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em Portugal, como em outros países, podem ser encontrados milhares de trabalhadores com doenças e outros problemas resultantes da exposição aos compostos orgânicos voláteis (COV’s). No entanto são poucos os estudos aplicados à actividade industrial. Neste trabalho validou-se/estimou-se a exposição ocupacional a COV´s dos trabalhadores que executam a tarefa de ‘aplicação de revestimento do mobiliário’, mais conhecida por ‘acabamento de móveis’ na secção de acabamentos do sector de mobiliário de madeira, que se situa nos concelhos de Paços de Ferreira e Paredes, concelhos do Norte de Portugal. A amostra foi constituída por 17 empresas e foram avaliados 34 tarefas que corresponde ao mesmo número de trabalhadores, uma vez que eles executam essa tarefa durante as oito horas diárias de trabalho. Para avaliar a exposição dos trabalhadores foram utilizadas duas abordagens da higiene do trabalho: a pragmática, através da aplicação do método Toolkit e a tradicional com recurso a amostragens de ar e análises laboratoriais. Os resultados obtidos sugerem que o Toolkit é uma boa ferramenta para ser utilizada pelas Pequenas e Médias Empresas (PME’s), que trabalhem com substâncias em pó ou líquidas. É um método expedito e que não acarreta grandes esforços financeiros. Verificou-se ainda que a maioria dos trabalhadores estão em risco de exposição a COV’s. Sendo necessário tomar medidas de controlo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a tartrate- (TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes showed behavior was best for membranes with o-nitrophenyl octyl ether as solvent. On injection of 500 μL into a phosphate buffer carrier (pH = 3.1; ionic strength 10–2 mol/L) flowing at 3 mL/min, the slope was 58.06 ± 0.6 with a lower limit of linear range of 5.0 × 10–4 mol/L TAT and R2 = 0.9989. The interference of several species, e.g. chloride, bromide, iodide, nitrate, gallic acid, tannin, sucrose, glucose, fructose, acetate, and citrate, was evaluated in terms of potentiometric selectivity coefficients. The Hofmeister series was followed for inorganic species and the most interfering organic ion was citrate. When red and white wines were analyzed and the results compared with those from an independent method they were found to be accurate, with relative standard deviations below 5.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system having a chlormequat selective electrode is proposed. Several electrodes with poly(vinyl chloride) based membranes were constructed for this purpose. Comparative characterization suggestedthe use of membrane with chlormequat tetraphenylborate and dibutylphthalate. On a single-line FIA set-up, operating with 1x10-2 mol L-1 ionic strength and 6.3 pH, calibration curves presented slopes of 53.6±0.4mV decade-1 within 5.0x10-6 and1.0x10-3 mol L-1, andsquaredcorrelation coefficients >0.9953. The detection limit was 2.2x10-6 mol L-1 and the repeatability equal to ±0.68mV (0.7%). A dual-channel FIA manifold was therefore constructed, enabling automatic attainment of previous ionic strength andpH conditions and thus eliminating sample preparation steps. Slopes of 45.5±0.2mV decade -1 along a concentration range of 8.0x10-6 to 1.0x10-3 mol L-1 with a repeatability ±0.4mV (0.69%) were obtained. Analyses of real samples were performed, and recovery gave results ranging from 96.6 to 101.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1×10−5 and 5.5×10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01×10−7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Celiac disease (CD) is an autoimmune enteropathy, characterized by an inappropriate T-cell-mediated immune response to the ingestion of certain dietary cereal proteins in genetically susceptible individuals. This disorder presents environmental, genetic, and immunological components. CD presents a prevalence of up to 1% in populations of European ancestry, yet a high percentage of cases remain underdiagnosed. The diagnosis and treatment should be made early since untreated disease causes growth retardation and atypical symptoms, like infertility or neurological disorders. The diagnostic criteria for CD, which requires endoscopy with small bowel biopsy, have been changing over the last few decades, especially due to the advent of serological tests with higher sensitivity and specificity. The use of serological markers can be very useful to rule out clinical suspicious cases and also to help monitor the patients, after adherence to a gluten-free diet. Since the current treatment consists of a life-long glutenfree diet, which leads to significant clinical and histological improvement, the standardization of an assay to assess in an unequivocal way gluten in gluten-free foodstuff is of major importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present work is to determine the antioxidant capacity (AC) of 27 commercial beers. The AC indicates the degree of protection of a certain organism against oxidative damage provoked by reactive oxygen and nitrogen species. Assays were carried out by the following methods: (i) total radical trapping antioxidant parameter (TRAP); (ii) trolox equivalent antioxidant capacity (TEAC); (iii) trolox equivalent antioxidant capacity (DPPH); (iv) ferric-ion reducing antioxidant parameter (FRAP); (v) cupric reducing antioxidant capacity (CUPRAC); (vi) oxygen radical absorbance capacity (ORAC). Ascorbic acid (AA), gallic acid (GA) and trolox (TR) were used as standards. All beers showed antioxidant power, but a wide range of ACs was observed. The effect of several factors upon these differences was studied. Statistical differences were found between ACs of beers of different colours. ORAC method provided always higher experimental ACs, of significant statistical differences to other assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.