43 resultados para domestic water heater
Resumo:
A glutathione-S-transferase (GST)based biosensor was developed to quantify the thiocarbamate herbicide molinate in environmental water.The biosensor construction was based on GST immobilization onto a glassy carbon electrode via aminosilane–glutaraldehyde covalent attachment. The principle supporting the use of this biosensor consists of the GST inhibition process promoted by molinate. Differential pulse voltammetry was used to obtain a calibration curve for molinate concentration, ranging from 0.19 to 7.9 mgL -1 and presenting a detection limit of 0.064 mgL- 1. The developed biosensor is stable,and reusable during 15 days.The GST-based biosensor was successfully applied to quantify molinate in rice paddy field floodwater samples. The results achieved with the developed biosensor were in accordance with those obtained by high performance liquid chromatography. The proposed device is suitable for screening environmental water analysis and, since no sample preparation is required, it can be used in situ and in real-time measurements.
Resumo:
Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.
Resumo:
Over the last few years, there has been a growing concern about the presence of pharmaceuticals in the environment. The main objective of this study was to develop and validate an SPE method using surface response methodology for the determination of ibuprofen in different types of water samples. The influence of sample pH and sample volume on the ibuprofen recovery was studied. The effect of each studied independent variable is pronounced on the dependent variable (ibuprofen recovery). Good selectivity, extraction efficiency, and precision were achieved using 600 mL of sample volume with the pH adjusted to 2.2. LC with fluorescence detection was employed. The optimized method was applied to 20 water samples from the North and South of Portugal.
Resumo:
O tratamento das águas residuais é uma matéria de extrema importância para o município da Póvoa de Varzim, não só por uma questão de saúde pública e conservação do meio ambiente como também pela vertente turística deste concelho, que tem na sua orla costeira seis praias às quais foram atribuídas bandeiras azuis pela sua qualidade. O concelho da Póvoa de Varzim engloba doze freguesias e possui quinze estações de tratamento de águas residuais (ETARs), sendo catorze delas compactas. O seu controlo é assegurado pela divisão de saneamento básico da câmara municipal da Póvoa de Varzim. O objetivo deste trabalho foi o diagnóstico de funcionamento das ETARs do município tendo em vista a identificação dos problemas existentes e a sua resolução/otimização. De forma a poder identificar o princípio de funcionamento e a presença de anomalias nas estações de tratamento, foram realizadas várias visitas a cada uma delas ao longo do período de estágio. A recolha de amostras para análises dos diferentes parâmetros foi feita por um funcionário e estas foram enviadas para o laboratório com parceria com a Câmara Municipal. Após uma extensa recolha de informação no local e de um estudo exaustivo de toda a documentação associada a cada ETAR concluiu-se que apenas quatro delas apresentavam problemas revelantes. As ETARs do parque industrial de Laúndos e do centro histórico de Rates apresentam caudais de admissão bastante elevados devido à descarga pontual de camiões cisterna o que faz com que o tratamento não seja eficaz. Como solução sugeriu-se a construção de um tanque de equalização em ambas as ETARs, com agitador e regulador de caudal, de forma a garantir, respetivamente, a mistura e uniformização das águas residuais domésticas e industriais e que apenas será bombeado o caudal adequado para tratamento. As ETARs da Incondave e das Fontaínhas apresentam sobretudo anomalias a nível do equipamento, o que leva a um mau desempenho da instalação. Aconselhou-se o conserto dos equipamentos danificados e uma inspeção mais frequente das instalações para que mal ocorra uma avaria, esta seja reparada o mais depressa possível. O estágio na câmara municipal da Póvoa de Varzim (CMPV) teve a duração de 10 meses, entre Outubro e Julho de 2012 e foi realizado no âmbito da disciplina de dissertação/ estágio do mestrado de tecnologias de proteção ambiental no Instituto Superior de Engenharia do Porto. Este estágio foi uma mais-valia para mim na medida em que pude consolidar os conhecimentos adquiridos ao longo de todo o meu percurso académico e conhecer a realidade do mercado de trabalho.
Resumo:
O consumo de energia a nível mundial tem atingido valores históricos, devido ao crescimento da população mundial e ao aumento do consumo per capita. Nesta medida é extremamente importante existirem alternativas para que a redução do consumo de energia de todos os países seja uma realidade, evitando também as consequências ambientais, em particular as alterações climáticas, resultantes da utilização intensiva de combustíveis fósseis. Portugal, tal como outros países da União Europeia, tem que cumprir metas, pelo que é urgente encontrarem-se soluções de forma a diminuir o consumo de energia sem interferir com o nosso dia-a-dia. A cidade do Porto, tal como qualquer cidade, precisa de imensa energia desde os transportes até à indústria, passando pelos edifícios. Os edifícios, residenciais e de serviços, são responsáveis por mais de 50% de energia primária consumida no concelho do Porto, sendo que aos edifícios residenciais corresponde um consumo de 1.473 GWh/ano de energia primária, o que é um valor elevado. Numa primeira parte deste trabalho foi efetuado um levantamento de informação caracterizando a cidade do Porto relativamente ao seu edificado e consumos energéticos. Numa segunda parte propuseram-se medidas para reduzir o consumo para cada tipo de utilização de energia, nomeadamente preparação de refeições, AQS (água quente sanitária), aquecimento ambiente, frio (frigorífico, arcas, etc.), outros e iluminação. Para cada um destes tipos de utilização estudou-se, sempre que possível, a evolução do longo do tempo (2004 a 2012) e possíveis cenários de evolução para o futuro. Para além disso, também se estudou a evolução do mix de produção de energia elétrica de 2004 até 2012 e previsões da evolução do mix para o futuro. Nesta análise foi tido em conta o aspeto ambiental contabilizando-se, sempre que possível, as emissões de poluentes resultantes do consumo de energia. Por fim, efetuou-se uma avaliação técnica, ambiental e económica das medidas propostas. Pode dizer-se que a maioria das medidas propostas a serem implementadas conduziria a uma redução do consumo de energia e consequentemente a uma diminuição das emissões de poluentes, em particular dos gases com efeito de estufa (CO2). Em termos técnicos a maioria das medidas pode ser aplicada embora algumas delas envolvam custos de investimento significativos. Dada a conjuntura atual, seria importante obter o financiamento necessário para a implementação das medidas propostas e a divulgação de medidas já existentes, tais como os programas para AQS e janelas eficientes.
Resumo:
A indústria da construção é um setor com grande impacto na economia, no Produto Interno Bruto (PIB) e ainda em postos de trabalho diretos e indiretos. No entanto, é um dos setores com maior impacte ambiental. Com a crise económica e financeira que o país atravessa, este setor foi um dos mais afetados, contribuindo para o aumento do desemprego visto tratar-se do setor com maior taxa de empregabilidade. Concomitantemente, ocorre saturação do mercado com a construção nova e desertificação dos centros urbanos com a degradação das habitações. Assim, como impulsionador da economia, surge a aposta na reabilitação do parque edificado que, com a legislação em vigor e com os incentivos dados pela tutela tem tudo para impulsionar o setor. Sabendo que a indústria da construção é um dos setores com maiores impactes ambientais, faz todo o sentido reabilitar-se de uma forma mais sustentável. Aplicando os princípios da sustentabilidade a todo o ciclo de vida do edifício, conseguimos reduzir os recursos na fase de construção (resíduos de construção) e na fase de exploração (consumo de energia e de água). Podemos ainda reduzir os custos de energia para climatização ao termos em conta a orientação do edifício e a envolvente, os recursos naturais e aplicando tecnologias solares passivas. Assim, ao aplicarmos os princípios da construção sustentável na reabilitação urbana podemos diminuir os impactes ambientais, a produção de CO2, as emissões de gases com efeito de estufa, os resíduos de construção e a área impermeabilizada.
Resumo:
STRIPPING is a software application developed for the automatic design of a randomly packing column where the transfer of volatile organic compounds (VOCs) from water to air can be performed and to simulate it’s behaviour in a steady-state. This software completely purges any need of experimental work for the selection of diameter of the column, and allows a choice, a priori, of the most convenient hydraulic regime for this type of operation. It also allows the operator to choose the model used for the calculation of some parameters, namely between the Eckert/Robbins model and the Billet model for estimating the pressure drop of the gaseous phase, and between the Billet and Onda/Djebbar’s models for the mass transfer. Illustrations of the graphical interface offered are presented.
Resumo:
Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.
Resumo:
This study aims to optimize the water quality monitoring of a polluted watercourse (Leça River, Portugal) through the principal component analysis (PCA) and cluster analysis (CA). These statistical methodologies were applied to physicochemical, bacteriological and ecotoxicological data (with the marine bacterium Vibrio fischeri and the green alga Chlorella vulgaris) obtained with the analysis of water samples monthly collected at seven monitoring sites and during five campaigns (February, May, June, August, and September 2006). The results of some variables were assigned to water quality classes according to national guidelines. Chemical and bacteriological quality data led to classify Leça River water quality as “bad” or “very bad”. PCA and CA identified monitoring sites with similar pollution pattern, giving to site 1 (located in the upstream stretch of the river) a distinct feature from all other sampling sites downstream. Ecotoxicity results corroborated this classification thus revealing differences in space and time. The present study includes not only physical, chemical and bacteriological but also ecotoxicological parameters, which broadens new perspectives in river water characterization. Moreover, the application of PCA and CA is very useful to optimize water quality monitoring networks, defining the minimum number of sites and their location. Thus, these tools can support appropriate management decisions.
Resumo:
In this study, the concentration probability distributions of 82 pharmaceutical compounds detected in the effluents of 179 European wastewater treatment plants were computed and inserted into a multimedia fate model. The comparative ecotoxicological impact of the direct emission of these compounds from wastewater treatment plants on freshwater ecosystems, based on a potentially affected fraction (PAF) of species approach, was assessed to rank compounds based on priority. As many pharmaceuticals are acids or bases, the multimedia fate model accounts for regressions to estimate pH-dependent fate parameters. An uncertainty analysis was performed by means of Monte Carlo analysis, which included the uncertainty of fate and ecotoxicity model input variables, as well as the spatial variability of landscape characteristics on the European continental scale. Several pharmaceutical compounds were identified as being of greatest concern, including 7 analgesics/anti-inflammatories, 3 β-blockers, 3 psychiatric drugs, and 1 each of 6 other therapeutic classes. The fate and impact modelling relied extensively on estimated data, given that most of these compounds have little or no experimental fate or ecotoxicity data available, as well as a limited reported occurrence in effluents. The contribution of estimated model input variables to the variance of freshwater ecotoxicity impact, as well as the lack of experimental abiotic degradation data for most compounds, helped in establishing priorities for further testing. Generally, the effluent concentration and the ecotoxicity effect factor were the model input variables with the most significant effect on the uncertainty of output results.
Resumo:
Mestrado em Engenharia Mecânica- Energia
Resumo:
A reabilitação é uma intervenção que confere ao edifício uma qualidade superior à que possuía aquando da sua construção. Desta forma, e com a entrada em vigor em final de 2013 da nova legislação referente à certificação energética dos edifícios, surge novamente o interesse na temática de reabilitar energeticamente o parque habitacional. Esta nova legislação aparece na sequencia das novas exigências da Comissão Europeia e do Parlamento Europeu face às alterações climáticas e consequentemente, em relação à eficiência energética. A reabilitação energética de edifícios, visa principalmente a melhoria das condições de conforto térmico, a redução dos consumos energéticos com aquecimento, arrefecimento e as águas quentes sanitárias. Tais melhorias são alcançáveis com intervenções que se foquem na envolvente dos edifícios, com a aplicação de sistemas de alta eficiência para o aquecimento, arrefecimento, iluminação e águas quentes sanitárias e com a integração de fontes de energias renováveis. Assim é possível alcançar edifícios com necessidades nulas ou quase nulas de energia, tal como exigem as metas impostas a nível europeu.
Resumo:
The implementation of smart homes allows the domestic consumer to be an active player in the context of the Smart Grid (SG). This paper presents an intelligent house management system that is being developed by the authors to manage, in real time, the power consumption, the micro generation system, the charge and discharge of the electric or plug-in hybrid vehicles, and the participation in Demand Response (DR) programs. The paper proposes a method for the energy efficiency analysis of a domestic consumer using the SCADA House Intelligent Management (SHIM) system. The main goal of the present paper is to demonstrate the economic benefits of the implemented method. The case study considers the consumption data of some real cases of Portuguese house consumption over 30 days of June of 2012, the Portuguese real energy price, the implementation of the power limits at different times of the day and the economic benefits analysis.
Resumo:
Recent and future changes in power systems, mainly in the smart grid operation context, are related to a high complexity of power networks operation. This leads to more complex communications and to higher network elements monitoring and control levels, both from network’s and consumers’ standpoint. The present work focuses on a real scenario of the LASIE laboratory, located at the Polytechnic of Porto. Laboratory systems are managed by the SCADA House Intelligent Management (SHIM), already developed by the authors based on a SCADA system. The SHIM capacities have been recently improved by including real-time simulation from Opal RT. This makes possible the integration of Matlab®/Simulink® real-time simulation models. The main goal of the present paper is to compare the advantages of the resulting improved system, while managing the energy consumption of a domestic consumer.
Resumo:
The recent changes concerning the consumers’ active participation in the efficient management of load devices for one’s own interest and for the interest of the network operator, namely in the context of demand response, leads to the need for improved algorithms and tools. A continuous consumption optimization algorithm has been improved in order to better manage the shifted demand. It has been done in a simulation and user-interaction tool capable of being integrated in a multi-agent smart grid simulator already developed, and also capable of integrating several optimization algorithms to manage real and simulated loads. The case study of this paper enhances the advantages of the proposed algorithm and the benefits of using the developed simulation and user interaction tool.