73 resultados para direct methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives : The purpose of this article is to find out differences between surveys using paper and online questionnaires. The author has deep knowledge in the case of questions concerning opinions in the development of survey based research, e.g. the limits of postal and online questionnaires. Methods : In the physician studies carried out in 1995 (doctors graduated in 1982-1991), 2000 (doctors graduated in 1982-1996), 2005 (doctors graduated in 1982-2001), 2011 (doctors graduated in 1977-2006) and 457 family doctors in 2000, were used paper and online questionnaires. The response rates were 64%, 68%, 64%, 49% and 73%, respectively. Results : The results of the physician studies showed that there were differences between methods. These differences were connected with using paper-based questionnaire and online questionnaire and response rate. The online-based survey gave a lower response rate than the postal survey. The major advantages of online survey were short response time; very low financial resource needs and data were directly loaded in the data analysis software, thus saved time and resources associated with the data entry process. Conclusions : The current article helps researchers with planning the study design and choosing of the right data collection method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The filter method is a technique for solving nonlinear programming problems. The filter algorithm has two phases in each iteration. The first one reduces a measure of infeasibility, while in the second the objective function value is reduced. In real optimization problems, usually the objective function is not differentiable or its derivatives are unknown. In these cases it becomes essential to use optimization methods where the calculation of the derivatives or the verification of their existence is not necessary: direct search methods or derivative-free methods are examples of such techniques. In this work we present a new direct search method, based on simplex methods, for general constrained optimization that combines the features of simplex and filter methods. This method neither computes nor approximates derivatives, penalty constants or Lagrange multipliers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A manipulação vertebral é um procedimento de terapia manual realizada em alta velocidade, pequena amplitude e normalmente no final de movimento. Estudos recentes sugerem a manipulação da coluna lombar com efeitos directos nos mecanismos neurofisiológicos da dor assim como na funcionalidade. Objectivo: Avaliar os efeitos, na dor e na funcionalidade, da manipulação lombar, em pacientes com dor lombar aguda de origem mecânica, no dia seguinte à manipulação. Materiais e Métodos: Participaram neste estudo três pacientes de ambos os sexos, com idades compreendidas entre os 31 e 35 anos, com queixas de dor lombar há menos de oito dias e que apresentavam restrição e dor nos movimentos de flexão lombar. Foi utilizado o teste de Mitchell para identificar as vértebras lombares disfuncionais. Os instrumentos utilizados foram a escala numérica da dor (END) para avaliar a dor e o questionário de incapacidade lombar Roland Morris (QIRM) para avaliar a funcionalidade. Os utentes foram avaliados antes da manipulação e no dia seguinte à sua aplicação. Em cada paciente foi realizada apenas uma manipulação lombar. Resultados: No dia seguinte à intervenção os pacientes apresentaram diminuição da dor (6/10 vs 0/10; 5/10 vs 3/10; 4/10vs 1/10) e melhoria da funcionalidade (7/24 vs 1/24; 16/24 vs 9/24; 8/24 vs3/24). Conclusão: Com base nos resultados obtidos pode concluir-se que, nestes três casos, a manipulação lombar utilizada, teve efeitos positivos na redução da dor e no aumento da funcionalidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a microwave-assisted extraction (MAE) methodology was compared with several conventional extraction methods (Soxhlet, Bligh & Dyer, modified Bligh & Dyer, Folch, modified Folch, Hara & Radin, Roese-Gottlieb) for quantification of total lipid content of three fish species: horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), and sardine (Sardina pilchardus). The influence of species, extraction method and frozen storage time (varying from fresh to 9 months of freezing) on total lipid content was analysed in detail. The efficiencies of methods MAE, Bligh & Dyer, Folch, modified Folch and Hara & Radin were the highest and although they were not statistically different, differences existed in terms of variability, with MAE showing the highest repeatability (CV = 0.034). Roese-Gottlieb, Soxhlet, and modified Bligh & Dyer methods were very poor in terms of efficiency as well as repeatability (CV between 0.13 and 0.18).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudo da incidência da perda auditiva e de problemas otológicos em comunidades escolares do Norte do país de um totalde 2550 participantes, entre os 3 e os 17 anos de idade. Desenho do Estudo: Levantamento estatístico nas próprias instituições de ensino sendo realizado um protocolo de avaliação auditiva de rastreio. Material e Métodos: A todos os participantes foi realizado o mesmo protocolo de avaliação que consistiu numa anamnese audiológica, otoscopia e exame audiométrico de rastreio, sendo considerado como critério de inclusão a autorização prévia por parte do encarregado de educação. Resultados: Foram identificados diversos problemas otológicos e a audiometria tonal de rastreio contabilizou limiares auditivos indicativos de hipoacusia, uni e bilateralmente, em cerca de 5,7% dos casos. Conclusões: O rastreio auditivo deve ser realizado o mais precocemente possível e fazer parte integral dos cuidados de saúde primários, de modo a orientar a criança para uma educação e acompanhamento apropriados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Although relative uptake values aren’t the most important objective of a 99mTc-DMSA scan, they are important quantitative information. In most of the dynamic renal scintigraphies attenuation correction is essential if one wants to obtain a reliable result of the quantification process. Although in DMSA scans the absent of significant background and the lesser attenuation in pediatric patients, makes that this attenuation correction techniques are actually not applied. The geometric mean is the most common method, but that includes the acquisition of an anterior (extra) projection, which it is not acquired by a large number of NM departments. This method and the attenuation factors proposed by Tonnesen will be correlated with the absence of attenuation correction procedures. Material and Methods: Images from 20 individuals (aged 3 years +/- 2) were used and the two attenuation correction methods applied. The mean time of acquisition (time post DMSA administration) was 3.5 hours +/- 0.8h. Results: The absence of attenuation correction showed a good correlation with both attenuation methods (r=0.73 +/- 0.11) and the mean difference verified on the uptake values between the different methods were 4 +/- 3. The correlation was higher when the age was lower. The attenuation correction methods correlation was higher between them two than with the “no attenuation correction” method (r=0.82 +/- 0.8), and the mean differences of the uptake values were 2 +/- 2. Conclusion: The decision of not doing any kind of attenuation correction method can be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for an accurate value of the relative kidney uptake, then an attenuation correction method should be used. Attenuation correction factors proposed by Tonnesen can be easily implemented and so become a practical and easy to implement alternative, namely when the anterior projection - needed for the geometric mean methodology – is not acquired.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho presente nesta dissertação incidiu sobre a aplicação das metodologias Lean no âmbito da manutenção de uma empresa metalomecânica de produção de Moldes – Simoldes Aços. No atual enquadramento, com os mercados nacionais e internacionais debaixo de feroz competição, as empresas são obrigadas a estudar métodos e técnicas que permitam eliminar desperdícios, reduzir custos e tempos de produção, ao mesmo tempo que são exigidos maiores níveis de qualidade dos produtos fabricados com vista ao aumento da competitividade. Sendo a Manutenção uma área funcional com um impacto elevado no desempenho da produção, é percebido que o desempenho desta, tem influência direta no comportamento do fluxo produtivo e nos respetivos níveis de eficácia e eficiência. No decorrer do trabalho desta dissertação de mestrado foi realizada uma análise abrangente do estado atual do sector de atividade de manutenção na empresa SIMOLDES SA, o que permitiu identificar as áreas e os pontos a intervir e desenhar as soluções de melhoria na atividade de manutenção. Na fase concludente do trabalho foram implementadas algumas dessas propostas de melhoria, ao passo que outras ficaram agendadas para futura implementação. Na base do trabalho desenvolvido esteve a metodologia Lean, que apresenta um papel relevante na implementação de uma abordagem integrada da função manutenção na manutenção dos objetivos da produção. O presente projeto baseou a sua estratégia de implementação na aplicação da ferramenta do 5S’ em paralelo com o TPM (Total Productive Maintenance). Ambas as ferramentas visam a redução de desperdícios e o aumento da fiabilidade dos processos, pelo aumento da disponibilidade dos equipamentos, da melhoria do desempenho dos processos e da plena integração de todos os colaboradores no processo de fabrico. Com a implementação das melhorias propostas, foram observados melhorias significativas no fluxo das atividades da manutenção, assim como uma maior visibilidade das mesmas em todo o processo produtivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apesar da enorme evolução tecnológica, os prazos na construção são cada vez mais reduzidos e os custos mais controlados, verificando-se uma despreocupação no que diz respeito a aspetos como a qualidade e durabilidade da construção das estruturas. Desperta assim nos técnicos, donos-de-obra, entidades executantes e projetistas a necessidade de avaliar o estado de conservação das estruturas de betão armado. Esta dissertação tem como objetivo principal abordar as anomalias e os mecanismos de deterioração mais correntes, os métodos de ensaio destrutivos ou parcialmente destrutivos mais utilizados e adequados, e abordar algumas das técnicas de reparação e reforço das estruturas de betão armado. Os principais danos apresentados nas estruturas são devidos a agentes físicos, mecânicos, biológicos e químicos. Podem ser devidos a causas diretas (acidentais ou naturais), que acarretam uma ação concreta sobre os elementos estruturais, e causas indiretas (humanas), diretamente ligadas com erros de projeto. É primordial fazer-se o levantamento de todas as anomalias existentes para se recorrer a um método de inspeção e ensaio. Consoante a necessidade de informação e estado da estrutura são selecionados os ensaios a realizar, podendo ser realizados “in situ” ou em laboratório. As técnicas de reparação e reforço são vistas como métodos para melhorar as condições da estrutura ao nível da segurança, desempenho, habitabilidade e durabilidade, prevenindo a evolução dos mecanismos de deterioração.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O rio Febros é um pequeno curso de água, situado no concelho de Vila Nova de Gaia, com cerca de 15 km de extensão, cuja bacia hidrográfica ocupa uma área de aproximadamente 35,4 km2. Nasce em Seixezelo e desagua na margem esquerda do Rio Douro no Cais do Esteiro, em Avintes. Em Maio de 2008, um acidente de viação teve como consequência o derrame de cerca de quatro toneladas de ácido clorídrico que rapidamente convergiu às águas do rio. Apenas um dia depois, o pH desceu para três e muitos foram os peixes que morreram. A solução adoptada para evitar o desaire foi introduzir milhares de litros de água de modo a diluir o ácido presente, ao longo de todo o curso de água. Tal facto não evitou a destruição de parte de um ecossistema, que ainda nos dias de hoje se encontra em recuperação. De forma a avaliar-se o impacto destas possíveis perturbações sejam estas de origem antropogénica ou natural é necessário possuir conhecimentos dos processos químicos tais como a advecção, a mistura devida à dispersão e a transferência de massa ar/água. Estes processos irão determinar o movimento e destino das substâncias que poderão ser descarregadas no rio. Para tal, recorrer-se-á ao estudo hidrogeométrico do curso de água assim como ao estudo do comportamento de um marcador, simulando uma possível descarga. A rodamina WT será o marcador a ser utilizado devido à panóplia de características ambientalmente favoráveis. Os estudos de campo com este corante, realizados em sequência de descarga previamente estudada, fornecem uma das melhores fontes de informação para verificação e validação de modelos hidráulicos utilizados em estudos de qualidade de águas e protecção ambiental. Escolheram-se dois pontos de descarga no Febros, um em Casal Drijo e outro no Parque Biológico de Gaia, possuindo cada um deles, a jusante, duas estações de monitorização. Pelo modelo ADE os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,3622; 0,5468; 1,6832 e 1,7504 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0633; 0,0684; 0,1548 e 0,1645 m/s. Quanto ao modelo TS, os valores obtidos para o coeficiente de dispersão longitudinal para as estações Pontão d’ Alheira, Pinheiral, Menesas e Giestas foram, respectivamente, 0,2339; 0,1618; 0,5057e 1,1320 m2/s. Para a mesma sequência de estações, os valores da velocidade de escoamento obtidos neste trabalho experimental foram de 0,0652; 0,0775; 0,1891 e 0,1676 m/s. Os resultados foram ajustados por um método directo, o método dos momentos, e por dois métodos indirectos, os modelos ADE e TS. O melhor ajuste corresponde ao modelo TS onde os valores do coeficiente de dispersão longitudinal e da velocidade de escoamento são aqueles que melhor se aproximam da realidade. Quanto ao método dos momentos, o valor estimado para a velocidade é de 0,162 m/s e para o coeficiente de dispersão longitudinal de 9,769 m2/s. Não obstante, a compreensão da hidrodinâmica do rio e das suas características, bem como a adequação de modelos matemáticos no tratamento de resultados formam uma estratégia de protecção ambiental inerente a futuros impactos que possam suceder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.