25 resultados para care costs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence indicates that exposure to high levels of noise adversely affects human health, and these effects are dependent upon various factors. In hospitals, there are many sources of noise, and high levels exert an impact on patients and staff, increasing both recovery time and stress, respectively. The goal of this pilot study was to develop, implement and evaluate the effectiveness of a training program (TP) on noise reduction in a Neonatal Intensive Care Units (NICU) by comparing the noise levels before and after the implementation of the program. A total of 79 health professionals participated in the study. The measurements of sound pressure levels took into account the layout of the unit and location of the main sources of noise. General results indicated that LAeq levels before implementation of the training program were often excessive, ranging from 48.7 ± 2.94 dBA to 71.7 ± 4.74 dBA, exceeding international guidelines. Similarly following implementation of the training program noise levels remained unchanged (54.5 ± 0.49 dBA to 63.9 ± 4.37 dBA), despite a decrease in some locations. There was no significant difference before and after the implementation of TP. However a significant difference was found for Lp, Cpeak, before and after training staff, suggesting greater care by healthcare professionals performing their tasks. Even recognizing that a TP is quite important to change behaviors, this needs to be considered in a broader context to effectively control noise in the NICU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1st ASPIC International Congress

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors have opened new horizons in biomedical analysis, by ensuring increased assay speed and flexibility, and allowing point-of-care applications, multi-target analyses, automation and reduced costs of testing. This has been a result of many studies merging nanotechnology with biochemistry over the years, thereby enabling the creation of more suitable environments to biological receptors and their substitution by synthetic analogue materials. Sol-gel chemistry, among other materials, is deeply involved in this process. Sol-gel processing allows the immobilization of organic molecules, biomacromolecules and cells maintaining their properties and activities, permitting their integration into different transduction devices, of electrochemical or optical nature, for single or multiple analyses. Sol-gel also allows to the production of synthetic materials mimicking the activity of natural receptors, while bringing advantages, mostly in terms of cost and stability. Moreover, the biocompatibility of sol-gel materials structures of biological nature allowed the use of these materials in emerging in vivo applications. In this chapter, biosensors for biomedical applications based on sol-gel derived composites are presented, compared and described, along with current emerging applications in vivo, concerning drug delivery or biomaterials. Sol-gel materials are shown as a promising tool for current, emerging and future medical applications. - See more at: http://www.eurekaselect.com/127191/article#sthash.iPqqyhox.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider two firms, located in different countries, selling the same homogeneous good in both countries. In each country there is a non negative tariff on imports of the good produced in the other country. We suppose that each firm has two different technologies, and uses one of them according to a certain probability distribution. The use of either one or the other technology affects the unitary production cost. We analyse the effect of the production costs uncertainty on the profits of the firms and also on the welfare of the governments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a trade policy model, where the costs of the home firm are private information but can be signaled through the output levels of the firm to a foreign competitor and a home policymaker. We compute the separating equilibrium and the Bayesian Nash equilibrium, and we compare the subsidies, firms’ expected profits and home government’s welfare in both equilibria, for different values of the own price effect parameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numa altura em que o setor da saúde é apontado como uma área crítica de gastos, nunca foi tão pertinente, pela falta de verbas, refletir e discutir o formato de contratação e de gestão dos cuidados de saúde. A sua fundamentação em custo, volume ou diferenciação, bem como, os indicadores que refletem o investimento, a eficiência e eficácia dos cuidados. Pretendeu-se como objetivo principal estudar a criação de valor no mercado da saúde enquanto fator diferenciador para a negociação de preços e competitividade em contexto de crise económica. Com vista a alcançar este objetivo, procedeu-se à revisão dos modelos teóricos, recorrendo a pesquisa bibliográfica. Procedeu-se também à comparação dos resultados operacionais de uma empresa enquanto prestadora de serviços de oxigenoterapia ao domicílio, tendo por base duas estratégias diferentes: redução direta de preços ou manutenção de preços com criação de valor para o cliente. Tendo em vista as duas estratégias, foram elaboradas duas propostas e posteriormente apresentadas para avaliação e votação on-line por um grupo oito gestores hospitalares. O valor em cuidados de saúde é visível nos benefícios clínicos alcançados pelo dinheiro investido. A estrutura dos atuais sistemas de saúde apenas reconhece redução de gastos, fontes de receita, volume de cuidados, sem orientação para a valorização dos resultados clínicos. Os prestadores deviam competir pela focalização na obtenção de melhores resultados clínicos, pois deve ser a essa a preocupação central dos serviços médicos. Uma boa gestão pode levar a que numa negociação de contratos, uma proposta baseada em valor possa garantir a manutenção dos preços.

Relevância:

20.00% 20.00%

Publicador: