22 resultados para Oxygen cost
Resumo:
Selenium modified ruthenium electrocatalysts supported on carbon black were synthesized using NaBH4 reduction of the metal precursor. Prepared Ru/C electrocatalysts showed high dispersion and very small averaged particle size. These Ru/C electrocatalysts were subsequently modified with Se following two procedures: (a) preformed Ru/carbon catalyst was mixed with SeO2 in xylene and reduced in H2 and (b) Ru metal precursor was mixed with SeO2 followed by reduction with NaBH4. The XRD patterns indicate that a pyrite-type structure was obtained at higher annealing temperatures, regardless of the Ru:Se molar ratio used in the preparation step. A pyrite-type structure also emerged in samples that were not calcined; however, in this case, the pyrite-type structure was only prominent for samples with higher Ru:Se ratios. The characterization of the RuSe/C electrocatalysts suggested that the Se in noncalcined samples was present mainly as an amorphous skin. Preliminary study of activity toward oxygen reduction reaction (ORR) using electrocatalysts with a Ru:Se ratio of 1:0.7 indicated that annealing after modification with Se had a detrimental effect on their activity. This result could be related to the increased particle size of crystalline RuSe2 in heat-treated samples. Higher activity of not annealed RuSe/C catalysts could also be a result of the structure containing amorphous Se skin on the Ru crystal. The electrode obtained using not calcined RuSe showed a very promising performance with a slightly lower activity and higher overpotential in comparison with a commercial Pt/C electrode. Single wall carbon nanohorns (SWNH) were considered for application as ORR electrocatalysts' supports. The characterization of SWNH was carried out regarding their tolerance toward strong catalyzed corrosion conditions. Tests indicated that SWNH have a three times higher electrochemical surface area (ESA) loss than carbon black or Pt commercial electrodes.
Resumo:
Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.
Resumo:
Currently, due to the widespread use of computers and the internet, students are trading libraries for the World Wide Web and laboratories with simulation programs. In most courses, simulators are made available to students and can be used to proof theoretical results or to test a developing hardware/product. Although this is an interesting solution: low cost, easy and fast way to perform some courses work, it has indeed major disadvantages. As everything is currently being done with/in a computer, the students are loosing the “feel” of the real values of the magnitudes. For instance in engineering studies, and mainly in the first years, students need to learn electronics, algorithmic, mathematics and physics. All of these areas can use numerical analysis software, simulation software or spreadsheets and in the majority of the cases data used is either simulated or random numbers, but real data could be used instead. For example, if a course uses numerical analysis software and needs a dataset, the students can learn to manipulate arrays. Also, when using the spreadsheets to build graphics, instead of using a random table, students could use a real dataset based, for instance, in the room temperature and its variation across the day. In this work we present a framework which uses a simple interface allowing it to be used by different courses where the computers are the teaching/learning process in order to give a more realistic feeling to students by using real data. A framework is proposed based on a set of low cost sensors for different physical magnitudes, e.g. temperature, light, wind speed, which are connected to a central server, that the students have access with an Ethernet protocol or are connected directly to the student computer/laptop. These sensors use the communication ports available such as: serial ports, parallel ports, Ethernet or Universal Serial Bus (USB). Since a central server is used, the students are encouraged to use sensor values results in their different courses and consequently in different types of software such as: numerical analysis tools, spreadsheets or simply inside any programming language when a dataset is needed. In order to do this, small pieces of hardware were developed containing at least one sensor using different types of computer communication. As long as the sensors are attached in a server connected to the internet, these tools can also be shared between different schools. This allows sensors that aren't available in a determined school to be used by getting the values from other places that are sharing them. Another remark is that students in the more advanced years and (theoretically) more know how, can use the courses that have some affinities with electronic development to build new sensor pieces and expand the framework further. The final solution provided is very interesting, low cost, simple to develop, allowing flexibility of resources by using the same materials in several courses bringing real world data into the students computer works.
Resumo:
This work presents a low cost RTK-GPS system for localization of unmanned surface vehicles. The system is based on the use of standard low cost L1 band receivers and in the RTKlib open source software library. Mission scenarios with multiple robotic vehicles are addressed as the ones envisioned in the ICARUS search and rescue case where the possibility of having a moving RTK base on a large USV and multiple smaller vehicles acting as rovers in a local communication network allows for local relative localization with high quality. The approach is validated in operational conditions with results presented for moving base scenario. The system was implemented in the SWIFT USV with the ROAZ autonomous surface vehicle acting as a moving base. This setup allows for the performing of a missions in a wider range of environments and applications such as precise 3D environment modeling in contained areas and multiple robot operations.
Resumo:
O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.
Resumo:
The high penetration of distributed energy resources (DER) in distribution networks and the competitive environment of electricity markets impose the use of new approaches in several domains. The network cost allocation, traditionally used in transmission networks, should be adapted and used in the distribution networks considering the specifications of the connected resources. The main goal is to develop a fairer methodology trying to distribute the distribution network use costs to all players which are using the network in each period. In this paper, a model considering different type of costs (fixed, losses, and congestion costs) is proposed comprising the use of a large set of DER, namely distributed generation (DG), demand response (DR) of direct load control type, energy storage systems (ESS), and electric vehicles with capability of discharging energy to the network, which is known as vehicle-to-grid (V2G). The proposed model includes three distinct phases of operation. The first phase of the model consists in an economic dispatch based on an AC optimal power flow (AC-OPF); in the second phase Kirschen's and Bialek's tracing algorithms are used and compared to evaluate the impact of each resource in the network. Finally, the MW-mile method is used in the third phase of the proposed model. A distribution network of 33 buses with large penetration of DER is used to illustrate the application of the proposed model.
Resumo:
Numa altura em que o setor da saúde é apontado como uma área crítica de gastos, nunca foi tão pertinente, pela falta de verbas, refletir e discutir o formato de contratação e de gestão dos cuidados de saúde. A sua fundamentação em custo, volume ou diferenciação, bem como, os indicadores que refletem o investimento, a eficiência e eficácia dos cuidados. Pretendeu-se como objetivo principal estudar a criação de valor no mercado da saúde enquanto fator diferenciador para a negociação de preços e competitividade em contexto de crise económica. Com vista a alcançar este objetivo, procedeu-se à revisão dos modelos teóricos, recorrendo a pesquisa bibliográfica. Procedeu-se também à comparação dos resultados operacionais de uma empresa enquanto prestadora de serviços de oxigenoterapia ao domicílio, tendo por base duas estratégias diferentes: redução direta de preços ou manutenção de preços com criação de valor para o cliente. Tendo em vista as duas estratégias, foram elaboradas duas propostas e posteriormente apresentadas para avaliação e votação on-line por um grupo oito gestores hospitalares. O valor em cuidados de saúde é visível nos benefícios clínicos alcançados pelo dinheiro investido. A estrutura dos atuais sistemas de saúde apenas reconhece redução de gastos, fontes de receita, volume de cuidados, sem orientação para a valorização dos resultados clínicos. Os prestadores deviam competir pela focalização na obtenção de melhores resultados clínicos, pois deve ser a essa a preocupação central dos serviços médicos. Uma boa gestão pode levar a que numa negociação de contratos, uma proposta baseada em valor possa garantir a manutenção dos preços.