25 resultados para Microtubule Motor Protein


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nutritional management is essential for Phenylketonuria (PKU) treatment, consisting in a semi-synthetic and low phenylalanine (Phe) diet, which includes strictly controlled amounts of low protein natural foods (essentially fruits and vegetables) supplemented with Phe-free protein substitutes and dietetic low-protein products. PKU diet has to be carefully planned, providing the best ingredient combinations, so that patients can achieve good metabolic control and an adequate nutritional status. Hereupon, it is mandatory to know the detailed composition of natural and/or cooked foodstuffs prepared specifically for these patients. We intended to evaluate sixteen dishes specifically prepared for PKU patients, regarding the nutritional composition, Phe and tyrosine (Tyr) contents, fatty acids profile, and vitamins E and B12 amounts. The nutritional composition of the cooked samples was 15.5–92.0 g/100 g, for moisture; 0.7–3.2 g/100 g, for protein; 0.1–25.0 g/100 g, for total fat; and 5.0–62.0 g/100 g, for total carbohydrates. Fatty acids profile and vitamin E amount reflected the type of fat used. All samples were poor in vitamin B12 (0.3–0.8 μg/100 g). Boiled rice presented the highest Phe content: 50.3 mg/g of protein. These data allow a more accurate calculation of the diet portions to be ingested by the patients according to their individual tolerance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nos dias de hoje a indústria tenta tornar-se cada vez mais competitiva baixando os custos de produção e aumentando a eficiência do produto. O presente trabalho visa desenvolver uma tampa de ventilação de um motor elétrico mais competitiva mas que cumpra com o desempenho mecânico e eficiência solicitados. Para tal, começou-se por analisar alguns motores elétricos e as suas aplicações. Seguidamente apresentam-se conceitos sobre aerodinâmica e processos de fabrico que permitem apoiar as opções tomadas ao longo do estudo. Após o fundamento teórico é apresentado todo o processo de desenvolvimento de uma nova peça. Recorrendo a softwares como o solidworks e Ansys, realizou-se uma análise analítica que permitiu validar as alterações propostas na tampa de ventilação. Foram, ainda, realizadas análises experimentais com o intuito de consolidar os resultados obtidos analiticamente e garantir que o componente cumpria os requisitos impostos por organizações internacionais ligadas à indústria do oil and gas. A primeira das análises experimentais realizada testa a capacidade do material resistir ao impacto de componentes de pequenas dimensões. Esta analise permitiu garantir a utilização da tampa de ventilação em todas as áreas sem limites de normalização. A segunda permite analisar experimentalmente as alterações de design assim como testar alguns trabalhos futuros. Esta análise permitiu definir se no novo projeto da tampa desenvolvido deveria comtemplar uma alteração do diâmetro da entrada de ar da tampa de ventilação. Como resultados aparecem as decisões tomadas na presente tese, assim como analisar as metas que foram atingidas e que melhorias se pretende atingir de futuro tentando visar novas metas. Os resultados obtidos permitiram definir uma nova tampa de ventilação com a nova que irá beneficiar a empresa na sua competitividade no mercado mantendo a performance do motor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O modelo matemático de um sistema real permite o conhecimento do seu comportamento dinâmico e é geralmente utilizado em problemas de engenharia. Por vezes os parâmetros utilizados pelo modelo são desconhecidos ou imprecisos. O envelhecimento e o desgaste do material são fatores a ter em conta pois podem causar alterações no comportamento do sistema real, podendo ser necessário efetuar uma nova estimação dos seus parâmetros. Para resolver este problema é utilizado o software desenvolvido pela empresa MathWorks, nomeadamente, o Matlab e o Simulink, em conjunto com a plataforma Arduíno cujo Hardware é open-source. A partir de dados obtidos do sistema real será aplicado um Ajuste de curvas (Curve Fitting) pelo Método dos Mínimos Quadrados de forma a aproximar o modelo simulado ao modelo do sistema real. O sistema desenvolvido permite a obtenção de novos valores dos parâmetros, de uma forma simples e eficaz, com vista a uma melhor aproximação do sistema real em estudo. A solução encontrada é validada com recurso a diferentes sinais de entrada aplicados ao sistema e os seus resultados comparados com os resultados do novo modelo obtido. O desempenho da solução encontrada é avaliado através do método das somas quadráticas dos erros entre resultados obtidos através de simulação e resultados obtidos experimentalmente do sistema real.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pain transmission at the spinal cord is modulated by descending actions that arise from supraspinal areas which collectively form the endogenous pain control system. Two key areas involved of the endogenous pain control system have a circunventricular location, namely the periaqueductal grey (PAG) and the locus coeruleus (LC). The PAG plays a crucial role in descending pain modulation as it conveys the input from higher brain centers to the spinal cord. As to the LC, it is involved in descending pain inhibition by direct noradrenergic projections to the spinal cord. In the context of neurological defects, several diseases may affect the structure and function of the brain. Hydrocephalus is a congenital or acquired disease characterized by an enlargement of the ventricles which leads to a distortion of the adjacent tissues, including the PAG and LC. Usually, patients suffering from hydrocephalus present dysfunctions in learning and memory and also motor deficits. It remains to be evaluated if lesions of the periventricular brain areas involved in pain control during hydrocephalus may affect descending pain control and, herein, affect pain responses. The studies included in the present thesis used an experimental model of hydrocephalus (the rat injected in the cisterna magna with kaolin) to study descending modulation of pain, focusing on the two circumventricular regions referred above (the PAG and the LC). In order to evaluate the effects of kaolin injection into the cisterna magna, we measured the degree of ventricular dilatation in sections encompassing the PAG by standard cytoarquitectonic stanings (thionin staining). For the LC, immunodetection of the noradrenaline-synthetizing enzyme tyrosine hydroxylase (TH) was performed, due to the noradrenergic nature of the LC neurons. In general, rats with kaolin-induced hydrocephalus presented a higher dilatation of the 4th ventricle, along with a tendency to a higher area of the PAG. Due to the validated role of detection the c-fos protooncogene as a marker of neuronal activation, we also studied neuronal activation in the several subnuclei which compose the PAG, namely the dorsomedial, dorsolateral, lateral and ventrolateral (VLPAG) parts. A decrease in the numbers of neurons immunoreactive for Fos protein (the product of activation of the c-fos protooncogene) was detected in rats injected with kaolin, whereas the remaining PAG subnuclei did not present changes in Fos-immunoreactive nuclei. Increases in the levels of TH in the LC, namely at the rostral parts of the nucleus, were detected in hydrocephalic animals. The following pain-related parameters were measured, namely 1) pain behavioural responses in a validated pain inflammatory test (the formalin test) and 2) the nociceptive activation of spinal cord neurons. A decrease in behavioral responses was detected in rats with kaolin-induced hydrocephalus was detected, namely in the second phase of the test (inflammatory phase). This is the phase of the formalin test in which the motor behaviour is less important, which is important since a semi-quantitative analysis of the motor performance of rats injected with kaolin indicates that these animals may present some motor impairments. Collectively, the results of the behavioral studies indicate that rats with kaolin-induced hydrocephalus exhibit hypoalgesia. A decrease in Fos expression was detected at the superficial dorsal layers of the spinal cord in rats with kaolin-induced hydrocephalus, further indicating that hydrocephalus decreases nociceptive responses. It remains to be ascertained if this is due to alterations in the PAG and LC in the rats with kaolin-induced hydrocephalus, which may affect descending pain modulation. It remains to be evaluated what are the mechanisms underlying the increased pain inhibition at the spinal dorsal horn in the hydrocephalus rats. Regarding the VLPAG, the decrease in neuronal activity may impair descending modulation. Since the LC has higher levels of TH in rats with kaolininduced hydrocephalus, which also appears to increase the noradrenergic innervation in the spinal dorsal horn, it is possible that an increase in the release of noradrenaline at the spinal cord accounts for pain inhibition. Our studies also determine the need to study in detail patients with hydrocephalus namely in what concerns their thresholds to pain and to perform imaging studies focused on the structure and function of pain control areas in the brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os motores de indução (MI) com rotor em gaiola de esquilo estão muito disseminados nos atuais sistemas de variação de velocidade (“drives”). A sua simplicidade e robustez, aliadas a baixos preços (comparativamente com outras máquinas) e ampla gama de potências disponíveis, são as principais razões. A evolução verificada nos domínios da eletrónica de potência e nos sistemas de controlo (em particular, o controlo digital), permitiram aplicar os MI em sistemas de elevado desempenho dinâmico (e.g., controlo de binário e/ou posição), substituindo os motores DC, cujas características dinâmicas e simplicidade de controlo os tornavam a primeira escolha em tais aplicações. Com efeito, as “drives” baseadas em MI apresentam características dinâmicas em tudo semelhantes aos sistemas DC, incluindo a possibilidade de funcionamento nos quatro quadrantes do plano (T, nr). No entanto, a complexidade do conversores e, sobretudo, dos sistemas de controlo é muito mais elevada nos sistemas AC. Os sistemas baseados no controlo vectorial são os mais usuais nas “drives” baseadas nas máquinas AC convencionais (assíncronas e síncronas). Existem outras metodologias também usadas na indústria (e.g., controlo direto do binário – DTC), mas neste trabalho somente o controlo vetorial será abordado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stroke is one of the most common conditions requiring rehabilitation, and its motor impairments are a major cause of permanent disability. Hemiparesis is observed by 80% of the patients after acute stroke. Neuroimaging studies showed that real and imagined movements have similarities regarding brain activation, supplying evidence that those similarities are based on the same process. Within this context, the combination of mental practice (MP) with physical and occupational therapy appears to be a natural complement based on neurorehabilitation concepts. Our study seeks to investigate if MP for stroke rehabilitation of upper limbs is an effective adjunct therapy. PubMed (Medline), ISI knowledge (Institute for Scientific Information) and SciELO (Scientific Electronic Library) were terminated on 20 February 2015. Data were collected on variables as follows: sample size, type of supervision, configuration of mental practice, setting the physical practice (intensity, number of sets and repetitions, duration of contractions, rest interval between sets, weekly and total duration), measures of sensorimotor deficits used in the main studies and significant results. Random effects models were used that take into account the variance within and between studies. Seven articles were selected. As there was no statistically significant difference between the two groups (MP vs control), showed a - 0.6 (95% CI: -1.27 to 0.04), for upper limb motor restoration after stroke. The present meta-analysis concluded that MP is not effective as adjunct therapeutic strategy for upper limb motor restoration after stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A síndrome dolorosa miofascial (SDM) é uma das causas mais comuns de dor com origem músculo-esquelética, devendo-se sobretudo à existência de pontos gatilho (PG) miofasciais. O PG no músculo trapézio superior (TS), sob a sua forma latente, tem repercussões no equilíbrio muscular do complexo articular do ombro. A intervenção sobre este PG, através da compressão isquémica poderá ter benefícios no próprio músculo e no controlo motor do complexo articular do ombro. Objetivos: Pretende-se estudar a influência da intervenção no PG latente do músculo TS no controlo motor do ombro, analisando as alterações ao nível do timing de ativação muscular, das sequências em que o músculos ativam e do nível de atividade muscular ao longo do movimento. Métodos: Foi realizado um estudo do tipo experimental, aleatório e controlado com uma amostra dividida em dois grupos, grupo experimental (n=15) e grupo controlo (n=14). No grupo experimental foi realizada a técnica de compressão isquémica no PG do TS e no grupo controlo um procedimento placebo. Antes e após a intervenção foi recolhida a atividade eletromiográfica dos músculos grande dentado (GD), infra-espinhoso (IE), deltóide médio (DM), trapézio superior (TS) e trapézio inferior (TI), assim como os dados cinemáticos, durante o movimento de elevação do ombro no plano da omoplata. Foi analisado o timing de ativação muscular, as sequências de ativação e o nível de ativação muscular ao longo do arco de movimento, através da magnitude normalizada à contração muscular voluntária máxima. Resultados: Foi observada uma maior pré ativação do músculo GD, no grupo experimental após a intervenção (p=0,025) relativamente ao primeiro momento de avaliação. É de notar que após a intervenção, no GE, todos os músculos passaram a ativar no período típico dos ajustes posturais antecipatórios, não tendo o mesmo sido observado no grupo de controlo. Após a técnica, 37% dos indivíduos do grupo experimental passaram a ativar o GD em primeiro lugar, quando apenas um sujeito o fazia antes da intervenção. Destaca-se também um predomínio de 32% nas últimas posições, após a técnica, dos músculos trapézio superior e inferior. No GC não se verifica nenhuma tendência após a intervenção. Foram ainda observadas diferenças estatisticamente significativas entre os grupos nos arcos de movimento onde foi atingido 20% da contração isométrica voluntária máxima (CMVI) nos músculos DM (p=0,002), na primeira avaliação, e IE (p=0,021), após a intervenção, com um atraso da ativação do IE para valores superiores a 20% da CMVI. Conclusão: A compressão isquémica reflete-se na antecipação da atividade do músculo GD e num atraso do aumento da magnitude da atividade do IE para valores moderados,