78 resultados para Mercury, Screen printed electrode, Burkina Faso, Pollution, Groundwater
Resumo:
Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.
Resumo:
A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.
Resumo:
Breast cancer is one of the most prevalent forms of cancer in women. Despite all recent advances in early diagnosis and therapy, mortality data is not decreasing. This is an outcome of the inexistence of validated serum biomarkers allowing an early prognosis, out coming from the limited understanding of the natural history of the disease. In this context, miRNAs have been attracting a special interest throughout the scientific community as promising biomarkers in the early diagnosis of cancer. In breast cancer, several miRNAs and their levels of expression are significantly different between normal tissue and tissue with neoplasia, as well as between different molecular subtypes of breast cancer, also associated with prognosis. Thus, this these presents a meta-analysis that allows identifying a reliable miRNA biomarker for the early detection of breast cancer. In this, miRNA-155 was identified as the best one and an electrochemical biosensor was developed for its detection in serum samples. The biosensor was assembled by following three button-up stages: (1) the complementary miRNA sequence thiol terminated (anti-miRNA-155) was immobilized on a commercial gold screen-printed electrode (Au-SPE), followed by (2) blocking non-specific binding with mercaptosuccinic acid and by (3) miRNA hybridization. The biosensor was able to detect miRNA concentrations lying in the 10-18 mol/L (aM) range, displaying a linear response from 10 aM to 1nM. The device showed a limit of detection of 5.7 aM in human serum samples and good selectivity against other biomolecules in serum, such as cancer antigen CA-15.3 and bovine serum albumin (BSA). Overall, this simple and sensitive strategy is a promising approach for the quantitative and/or simultaneous analysis of multiple miRNA in physiological fluids, aiming at further biomedical research devoted to biomarker monitoring and point-of-care diagnosis.
Resumo:
Disposable screen-printed electrodes (SPCE) were modified using a cosmetic product to partially block the electrode surface in order to obtain a microelectrode array. The microarrays formed were electropolymerized with aniline. Scanning electron microscopy was used to evaluate the modified and polymerized electrode surface. Electrochemical characteristics of the constructed sensor for cadmium analysis were evaluated by cyclic and square-wave voltammetry. Optimized stripping procedure in which the preconcentration of cadmium was achieved by depositing at –1.20 V (vs. Ag/AgCl) resulted in a well defined anodic peak at approximately –0.7 V at pH 4.6. The achieved limit of detection was 4 × 10−9 mol dm−3. Spray modified and polymerized microarray electrodes were successfully applied to quantify cadmium in fish sample digests.
Resumo:
O presente trabalho tem como objectivo o desenvolvimento de um método analítico, baseado na voltametria de onda quadrada (SWV), para a análise de ciprofloxacina (CIP) em produtos farmacêuticos e em processos de remediação. Para o desenvolvimento do método voltamétrico foram utilizadas duas células voltamétricas: a célula clássica (utilizando um eléctrodo de trabalho de carbono vítreo - GCE) e um eléctrodo de carbono impresso (SPCE). Após a optimização dos parâmetros da SWV, pH (3,04), frequência (400Hz), incremento de potencial (6 mV) e amplitude do impulso de potencial (40 mV), procedeu-se a validação dos métodos, obtendo-se zonas lineares entre a concentração de CIP e a intensidade de corrente de pico de 5,0×10-6 a 6,0×10-5 mol/L (GCE) e de 1,0×10-5 a 4,0×10-5 mol/L (SPCE) e limites de detecção de 9,48×10-6 mol/L (GCE) e 2,13×10-6 mol/L (SPCE). Verificou-se que a sensibilidade, a precisão e a selectividade são superiores para o SPCE, sendo por isso esta a célula mais adequada para proceder à análise da CIP em produtos farmacêuticos. O SPCE foi aplicado com sucesso à análise de CIP num produto farmacêutico. Para o tratamento de soluções aquosas contendo a CIP foram testados dois oxidantes: o permanganato de potássio e o peróxido de hidrogénio. Para o peróxido de hidrogénio os resultados obtidos foram inconclusivos. No caso do permanganato de potássio, os resultados mostram que a degradação da ciprofloxacina depende da concentração do oxidante. Para uma concentração de CIP de 3,00×10-4 mol/L uma degradação rápida foi obtida com o uso de 6,00×10-3 mol/L de permanganato de potássio. Na aplicação do permanganato na remediação de solos verificou-se que no caso de solos húmicos a ciprofloxacina é adsorvida pelo solo, não sendo possível confirmar a ocorrência da reacção de degradação. No caso de solos arenosos verificou-se que a ciprofloxacina foi rapidamente degradada pelo permanganato de potássio.
Resumo:
A nanohybrid electrochemical transducer surface was developed using carbon and gold nanomaterials. The strategy relayed on casting multiwalled carbon nanotubes or carbon nanofibers onto a screen-printed carbon electrode surface, followed by in situ generation of gold nanoparticles by electrochemical deposition of ionic gold, in a reproducible manner. These transducers, so fabricated, were characterized using both electrochemical and microscopic techniques. Biofunctionality was evaluated using the streptavidin-biotin interaction system as the biological reaction model. These platforms allow to achieve low detection limits (in the order of pmoles), are reproducible and stable at least for a month after their preparation, being a perfect candidate to be used as transducer of different sensor devices.
Resumo:
The first electrochemical immunosensor (EI) for the detection of antibodies against deamidated gliadin peptides (DGP) is described here. A disposable nanohybrid screen-printed carbon electrode modified with DGP was employed as the transducer's sensing surface. Real serumsampleswere successfully assayed and the results were corroborated with an ELISA kit. The presented EI is a promising analytical tool for celiac disease diagnosis.
Resumo:
Celiac disease (CD) is a gluten-induced autoimmune enteropathy characterized by the presence of antibodies against gliadin (AGA) and anti-tissue transglutaminase (anti-tTG) antibodies. A disposable electrochemical dual immunosensor for the simultaneous detection of IgA and IgG type AGA and antitTG antibodies in real patient’s samples is presented. The proposed immunosensor is based on a dual screen-printed carbon electrode, with two working electrodes, nanostructured with a carbon–metal hybrid system that worked as the transducer surface. The immunosensing strategy consisted of the immobilization of gliadin and tTG (i.e. CD specific antigens) on the nanostructured electrode surface. The electrochemical detection of the human antibodies present in the assayed serum samples was carried out through the antigen–antibody interaction and recorded using alkaline phosphatase labelled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions was used as the substrate. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with commercial ELISA kits indicating that the developed sensor can be a good alternative to the traditional methods allowing a decentralization of the analyses towards a point-of-care strategy.
Resumo:
Human epidermal growth factor receptor 2 (HER2) is a breast cancer biomarker that plays a major role in promoting breast cancer cell proliferation and malignant growth. The extracellular domain (ECD) of HER2 can be shed into the blood stream and its concentration is measurable in the serum fraction of blood. In this work an electrochemical immunosensor for the analysis of HER2 ECD in human serum samples was developed. To achieve this goal a screen-printed carbon electrode, modified with gold nanoparticles, was used as transducer surface. A sandwich immunoassay, using two monoclonal antibodies, was employed and the detection of the antibody–antigen interaction was performed through the analysis of an enzymatic reaction product by linear sweep voltammetry. Using the optimized experimental conditions the calibration curve (ip vs. log[HER2 ECD]) was established between 15 and 100 ng/mL and a limit of detection (LOD) of 4.4 ng/mL was achieved. These results indicate that the developed immunosensor could be a promising tool in breast cancer diagnostics, patient follow-up and monitoring of metastatic breast cancer since it allows quantification in a useful concentration range and has an LOD below the established cut-off value (15 ng/mL).
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
In the present work, the development of a genosensor for the event-specific detection of MON810 transgenic maize is proposed. Taking advantage of nanostructuration, a cost-effective three dimensional electrode was fabricated and a ternary monolayer containing a dithiol, a monothiol and the thiolated capture probe was optimized to minimize the unspecific signals. A sandwich format assay was selected as a way of precluding inefficient hybridization associated with stable secondary target structures. A comparison between the analytical performance of the Au nanostructured electrodes and commercially available screen-printed electrodes highlighted the superior performance of the nanostructured ones. Finally, the genosensor was effectively applied to detect the transgenic sequence in real samples, showing its potential for future quantitative analysis.
Resumo:
There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.
Resumo:
Antibodies against gliadin are used to detect celiac disease (CD) in patients. An electrochemical immunosensor for the voltammetric detection of human anti-gliadin antibodies (AGA) IgA and AGA IgG in real serum samples is proposed. The transducer surface consists of screen-printed carbon electrodes modified with a carbon nanotube/gold nanoparticle hybrid system, which provides a very useful surface for the amplification of the immunological interactions. The immunosensing strategy is based on the immobilization of gliadin, the antigen for the autoantibodies of interest, onto the nanostructured surface. The antigen–antibody interaction is recorded using alkaline phosphatase labeled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions (3-IP/Ag+) was used as the substrate. The analytical signal is based on the anodic redissolution of the enzymatically generated silver by cyclic voltammetry. The electrochemical behavior of this immunosensor was carefully evaluated assessing aspects as sensitivity, non-specific binding and matrix effects, and repeatability and reproducibility. The results were supported with a commercial ELISA test.
Resumo:
O cancro é uma das principais causas de morte em todo o mundo. Entre as mulheres, o cancro da mama é o mais frequente. A deteção precoce do cancro é de extrema importância na medida em que pode aumentar as possibilidades de cura dos pacientes e contribuir para a diminuição da taxa de mortalidade desta doença. Um método que tem contribuído para a deteção precoce do cancro é a análise de biomarcadores. Biomarcadores associados ao cancro da mama, como o Recetor 2 do Fator de Crescimento Epidérmico Humano (HER2) e o Antigénio Carbohidratado 15-3 (CA 15-3), podem ser detetados através de dispositivos como os biossensores. Neste trabalho foram desenvolvidos dois imunossensores eletroquímicos para a análise de HER2 e CA 15-3. Para ambos os sensores foram utilizados, como transdutores, elétrodos serigrafados de carbono. A superfície destes transdutores foi nanoestruturada com nanopartículas de ouro. Foram realizados imunoensaios não-competitivos (do tipo sandwich) em ambos os imunossensores, cuja estratégia consistiu na (i) imobilização do respetivo anticorpo de captura na superfície nanoestruturada dos elétrodos, (ii) bloqueio da superfície com caseína, (iii) incubação com uma mistura do analito (HER2 ou CA 15-3) e o respetivo anticorpo de deteção biotinilado, (iv) adição de estreptavidina conjugada com fosfatase alcalina (S-AP; a AP foi utilizada como marcador enzimático), (v) adição de uma mistura do substrato enzimático (3-indoxil fosfato) e nitrato de prata, e (vi) deteção do sinal analítico através da redissolução anódica, por voltametria de varrimento linear, da prata depositada enzimaticamente. Com as condições experimentais otimizadas, foi estabelecida a curva de calibração para a análise de HER2 em soro, entre 15 e 100 ng/mL, obtendo-se um limite de deteção de 4,4 ng/mL. Para o CA 15-3 a curva de calibração (em solução aquosa) foi estabelecida entre 15 e 250 U/mL, obtendo-se um limite de deteção de 37,5 U/mL. Tendo em conta o valor limite (cutoff value) estabelecido para o HER2 (15 ng/mL) pode-se comprovar a possível utilidade do imunossensor desenvolvido para o diagnóstico precoce e descentralizado do cancro da mama. No caso do CA 15-3 serão necessários estudos adicionais para se poder avaliar a utilidade do imunossensor para o diagnóstico do cancro da mama.
Resumo:
Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.