38 resultados para C. M. Vila Franca de Xira


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores - Área de Especialização de Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coletânea de artigos no âmbito da Conferência Investigação e Intervenção em Recursos Humanos: Gestão para a Cidadania, Vila do Conde, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prescribed fire is a technique that is often used, it has several advantages. Pedological and hydropedological techniques were tested to assess the prescribed fire changes may cause in soils. This work was performed in Tresminas area (Vila Pouca de Aguiar, Northern Portugal), during February and March 2011. In the present study we applied several techniques. For the field sampling was followed the ISO 10381-1[1], ISO 10381-2[2], and FAO rules [3], as well as were used a grid with 17 points for measuring the soil parameters. During the fire, we have tried to check, with the assistance of the Portuguese Forestry Authority, some important parameters such as, the propagation speed, the size of the flame front and the intensity of energy emitted per unit area. Before the fire, was collected carefully soil disturbed and undisturbed samples for laboratory analysis, and measured soil water content; we also have placed four sets of thermocouples for measuring soil temperature. After the fire, were collected the thermocouples and new soil samples; the water content were measured in the soil and collected ashes. In the laboratory, after preparing and sieving the samples, were determined the soil particle size. The soil pH and electrical conductivity in water was also determined. The total carbon (TC) and inorganic carbon (IC)[4] was measured by a Shimadzu TOC-Vcsn. The water content in soil has not varied significantly before and after the fire, as well as soil pH and soil electrical conductivity. The TC and IC did not change, which was expected, since the fire not overcome the 200° C. Through the various parameters, we determined that the prescribed fire didn’t affect the soil. The low temperature of the fire and its rapid implementation that lead to the possible adverse effects caused by the wild fire didn’t occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado em Auditoria apresentado ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do Grau de Mestre em Auditoria, sob Orientação de: Professora Doutora Alcina Augusta de Sena Portugal Dias

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação de Professora Doutora Ana Maria Alves Bandeira e Professora Doutora Deolinda Meira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho de investigação tem como objetivo analisar se as empresas do concelho de Vila do Conde, efetuam planeamento estratégico, contabilidade de gestão e/ou gestão de risco. Pretende-se ainda verificar se o facto de existir articulação entre estas três áreas da empresa influencia o resultado do seu EBIT (Earning Before Interest and Taxes). Através da literatura relevante, verificou-se que o planeamento estratégico, a contabilidade de gestão e a gestão de riscom progredido de modo a responder às mudanças do meio envolvente onde as empresas estão a operar. Contudo, em termos práticos, este estudo permitiu verificar que a implementação da gestão de risco e da contabilidade de gestão no tecido empresarial de Vila do Conde tem sido muito lenta. Os dados foram recolhidos através dum inquérito eletrónico efetuado a 505 empresas do concelho de Vila do Conde de diversas atividades ecomicas pertencentes aos três grandes sectores (serviços, indústria e comrcio). De acordo com os resultados obtidos, concluiu-se que apenas 17% das empresas do concelho de Vila do Conde efetuam simultâneamente planeamento estratégico, contabilidade de gestão e gestão de risco. Conclui-se ainda que as empresas do concelho de Vila do Conde que efetuam em simultâneo planeamento estratégico, contabilidade de gestão e gestão de risco apresentam em mdia um EBIT (2010) aparenta ser superior às que não fazem planeamento estratégico, contabilidade de gestão e gestão de risco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A eficiência energética e a preocupação com a sustentabilidadem vindo a ganhar preponderância na sociedade moderna. Este trabalho é uma contribuição para esta tendência onde se pretendeu avaliar e sugerir alterações ao sistema de climatização do edifício Biorama do Parque Biológico de Vila Nova de Gaia (PBG). Procedeu-se em primeiro lugar a uma caracterização física, química e geográfica dos 5 biomas constituintes do Biorama. Para isso, recorreu-se a documentos fornecidos pelo próprio PBG, visitas ao local e registo de medições de alguns parâmetros (temperatura, humidade relativa, qualidade do ar). Posteriormente foi realizado o balanço térmico dos edifícios, de acordo com a legislação em vigor, recorrendo a expressões e conceitos teóricos. Foram determinados valores dos ganhos térmicos de aquecimento de 15811, 10694, 7939, 9233, e 6621 kWh/ano para Floresta tropical, Mesozoico, Dunas, Savana e Deserto, respetivamente. Foram igualmente determinados valores dos ganhos térmicos no verão de 7093, 4798, 3560, 4144 e 2971 kWh na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de aquecimento foram 149, 125, 47, 60 e 51 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de arrefecimento foram iguais a 59, 57, 47, 35 e 36 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. Algumas soluções são avançadas, bem como alternativas comportamentais de modo a corrigir alguns problemas identificados. Uma proposta é a da instalação de painéis solares e acumuladores de calor, com os quais se estima um ganho mdio conjunto de 500 W em cada bioma, e representam um investimento de 1050 euros e terão um retorno de 1 ano. Em relação à humidade é sugerido a utilização mais eficaz dos aspersores existentes e a utilização de esponjas, para fazer subir a humidade relativa para valores superiores a 80%. Em sentido inverso, no inverno, propõem-se a utilização de material higroscpico para fazer baixar a humidade relativa em cerca de 5%. Os custos com os suportes e o material higroscpico rondam os 250 €. Por fim, é sugerido a instalação de um aparelho de ar condicionado de 16 000 BTU no corredor de ligação, pois é a única forma de garantir condições de conforto térmico. Esta proposta de arrefecimento com ar condicionado e ainda o recurso a uma cortina deminas de plástico, que servem para efetuar uma separação mais eficiente entre ar frio e ar quente, têm um custo aproximado de 350 €. É ainda sugerida a utilização de lonas ou de uma planta trepadeira com um custo por planta de 5€, nas coberturas dos telhados virados a sul, sendo que a zona do corredor deverá ser totalmente coberta, a fim de evitar a exposição solar direta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the first phase of the redevelopment of the Electric Vehicle Scenario Simulator (EVeSSi) tool. A new methodology to generate traffic demand scenarios for the Simulation of Urban MObility (SUMO) tool for urban traffic simulation is described. This methodology is based on a Portugal census database to generate a synthetic population for a given area under study. A realistic case study of a Portuguese city, Vila Real, is assessed. For this area the road network was created along with a synthetic population and public transport. The traffic results were obtained and an electric buses fleet was evaluated assuming that the actual fleet would be replaced in a near future. The energy requirements to charge the electric fleet overnight were estimated in order to evaluate the impacts that it would cause in the local electricity network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artigo surgiu na sequência de um atelier “Une langue étrangère, un ordinateur, une image: cest simple comme bonjour!”, desenvolvido no âmbito do XXI Congresso da Associação Portuguesa dos Professores de Francs, Images et imaginaires pour agir. Teve como propósito divulgar, experimentar e refletir sobre recursos digitais que podem dar um bom contributo ao processo de ensino e aprendizagem do Francs Língua Estrangeira (FLE). Evidencia-se o poder da imagem na construção do conhecimento, desafiando a criatividade e novos modos de ensinar a aprender. Verificou-se que os professores se interessaram pelas ferramentas digitais e evidenciaram a sua importância e a sua aplicabilidade nos contextos educativos. Neste sentido, o artigo divulga ferramentas informticas focadas no desenvolvimento da oralidade/leitura/escrita do francs língua estrangeira, refere boas práticas de utilização em contexto de sala de aula, constituindo uma contribuição para a renovação da escola.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inaugurada em 1895 junto a Elvas, a Colónia Agrícola Correcional de Vila Fernando procurava a regeneração de jovens por meio do trabalho, buscando também acabar com as péssimas condições a que estavam sujeitos os jovens ao serem encarcerados com os adultos, nas cadeias do país. Analisaremos, no período compreendido entre finais do século XIX e início do século XX, os diferentes processos educativos presentes no quotidiano da instituição, nas práticas do trabalho, da formação profissional e do ensino escolar, procurando averiguar, numa perspetiva histórico-pedagógica, de que modo a instituição foi capaz de conciliar o cacter disciplinador do trabalho com a reintegração social.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de estágio apresentado no Instituto Superior de Contabilidade e Administração do Porto para obtenção do Grau de Mestre em Gestão das Organizações, Ramo de Gestão de Empresas Orientado por Prof. Doutor Eduardo Manuel Lopes de Sá e Silva Co-Orientado pelo Mestre Adalmiro Álvaro Malheiro de Castro Andrade Pereira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projeto apresentado ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Gestão das Organizações, Ramo de Gestão de Empresas Orientação Científica: Professor Doutor Eduardo de Sá e Silva | Doutora Fátima Monteiro Orientação Técnica: Dr. Paulo Costa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings of the 12th European Conference on Wireless Sensor Networks (EWSN'15), 9-11 Feb 2015, Porto-Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissertação teve como finalidade a realização de uma Auditoria Energética e da Qualidade do Ar Interior ao edifício de serviços da Cmara Municipal de Vila Nova de Gaia. No intuito de alcançar esta finalidade foram seguidos, em todo o processo, os regulamentos em vigor até à presente data da dissertação, de apoio à especialidade, nomeadamente o Regulamento das Características de Comportamento Térmico dos Edifícios, Regulamento dos Sistemas Energéticos de Climatização em Edifícios e Regulamento dos Sistemas Energéticos de Climatização em Edifícios e da Qualidade do Ar Interior. Na análise à Qualidade do Ar Interior foram verificados quase todos os parâmetros impostos por lei, exceto os das bactérias e dos fungos. Para as substâncias como dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCOH) e radão, os valores em mdia foram iguais a 894 ppm, 1,23 ppm, 0,07 ppm, 0,01 ppm e 378 Bq/m3 e estavam dentro dos limites regulamentares (984 ppm, 10,7ppm, 0,10 ppm, 0,08 ppm e 400 Bq/m3). Para os compostos orgânicos voláteis (COVs) e partículas do tipo PM10, os valores respetivos foram em mdia de 0,70 ppm e 0,16 mg/m3 e estavam acima dos limites regulamentares (0,26 ppm, 0,15 mg/m3). Admite-se que existem fontes emissoras de COVs dentro do edifício e que, para uma adequação ao tipo de tratamento ou sugestão de melhoria, seria necessário realizar uma análise por cromatografia de forma a identificar os compostos em causa. As concentrações de PM10 mais elevadas explicam-se porque existe uma abertura direta desses espaços ao exterior e em alguns casos esta é permanente. A análise energética permitiu um levantamento de todos os consumos de energia elétrica do edifício, realizando deste modo a desagregação em percentagem de cada equipamento consumidor. Em paralelo e até para se poder realizar a certificação energética do edifício foi realizado um estudo de simulação térmica dinâmica recorrendo ao programa DesignBuilder v2. Criou-se um modelo do edifício que foi validado após simulação e comparação com o consumo elétrico do ano de referência (desvio de 2,78%). Pela simulação verificou-se que os maiores consumidores de energia são a iluminação interior e o sistema de arrefecimento e determinou-se os Indicadores de Eficiência Energética (IEE) Real (com correção climtica) e Nominal com valores de 73,8 e 46,5 , respetivamente. Implementando as condições nominais de utilização e funcionamento no edifício, segundo o Regulamento dos Sistemas Energéticos de vi Climatização em Edifícios (RSECE), concluiu-se que a classe energética deste edifício é do tipo D. O valor do IEE nominal foi superior ao IEE referência de 35,5 , e o requisito legal não se verificou. Assim, foi necessário apresentar medidas para um plano de racionalização energética (PRE). Nas medidas estudadas de melhoria da eficiência energética (aplicação de películas solares, compensação do fator de potência, instalação de um sistema de minigeração fotovoltaico e aplicação de iluminação eficiente tanto no interior como no exterior do edifício) destaca-se a correção do fator de potência, pois o valor pago de energia reactiva em 2011 foi de cerca de 1500 €. Admitindo ser necessário redimensionar os condensadores e que o custo é 1.840,00 €, ter-se-á um retorno do investimento em 1,2 anos. Outra medida é a aplicação de películas solares nos envidraçados com um custo de 5.046,00 €, esta terá um período de retorno de 1 ano e uma poupança de 37,90 MWh/ano. Finalmente refere-se a instalação de reguladores de tensão e substituição de determinadas lâmpadas por LEDs na iluminação interior, que prevê uma poupança anual de 25 MWh/ano e um período de retorno do investimento de 3,7 anos.