50 resultados para Base shear recovery
Resumo:
Interest in polyethylene and polypropylene bonding has increased in the last years. However, adhesive joints with adherends which are of low surface energy and which are chemically inert present several difficulties. Generally, their high degree of chemical resistance to solvents and dissimilar solubility parameters limit the usefulness of solvent bonding as a viable assembly technique. One successful approach to adhesive bonding of these materials involves proper selection of surface pre-treatment prior to bonding. With the correct pre-treatment it is possible to glue these materials with one or more of several adhesives required by the applications involved. A second approach is the use of adhesives without surface pre-treatment, such as hot melts, high tack pressure-sensitive adhesives, solvent-based specialty adhesives and, more recently, structural acrylic adhesives as such 3M DP-8005® and Loctite 3030®. In this paper, the shear strengths of two acrylic adhesives were evaluated using the lap shear test method ASTM D3163 and the block shear test method ASTM D4501. Two different industrial polyolefins (polyethylene and polypropylene) were used for adherends. However, the focus of this study was to measure the shear strength of polyethylene joints with acrylic adhesives. The effect of abrasion was also studied. Some test specimens were manually abraded using 180 and 320 grade abrasive paper. An additional goal of this work was to examine the effect of temperature and moisture on mechanical strength of adhesive joints.
Resumo:
In this work, the shear modulus and strength of the acrylic adhesive 3M® DP 8005 was evaluated by two different methods: the Thick Adherend Shear Test (TAST) and the Notched Plate Shear Method (Arcan). However, TAST standards advise the use of a special extensometer attached to the specimen, which requires a very experienced technician. In the present study, the adhesive shear displacement for the TAST was measured using an optical technique, and also with a conventional inductive extensometer of 25 mm used for tensile tests. This allowed for an assessment of suitability of using a conventional extensometer to measure this parameter. Since the results obtained by the two techniques are identical, it can be concluded that using a conventional extensometer is a valid option to obtain the shear modulus for the particular adhesive used. In the Arcan tests, the adhesive shear displacement was only measured using the optical technique. This work also aimed the comparison of shear modulus and strength obtained by the TAST and Arcan test methods.
Resumo:
Mestrado em Engenharia Química. Ramo optimização energética na indústria química
Resumo:
Dissertação apresentada ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Gestão das Organizações, Ramo Gestão de Empresas Orientada por: Profª Doutora Maria Alexandra Pacheco Ribeiro da Costa Esta dissertação inclui as críticas e sugestões feitas pelo Júri.
Resumo:
Até 2020, a Europa terá de reduzir 20% das suas emissões de gases com efeito de estufa, 20% da produção de energia terá de ser proveniente de fontes renováveis e a eficiência energética deverá aumentar 20%. Estas são as metas apresentadas pela União Europeia, que ficaram conhecidas por 20/20/20 [1]. A Refinaria de Matosinhosé um complexo industrial que opera no sector da refinação e que apresenta preocupações ao nível da eficiência energética e dos aspectos ambientais subjacentes. No âmbito da racionalização energética das refinarias, a Galp Energia tem vindo a implementar um conjunto de medidas, adoptando as melhores tecnologias disponíveis com o objectivo de diminuir os consumos de energia, promover a eficiência energética e reduzir as emissões de dióxido de carbono. Para ir de encontro a estas medidas foi elaborado um estudo comparativo que permitiu à empresa definir as medidas consideradas prioritárias. Uma solução encontrada visa a execução de projectos que não requerem investimento e que têm acções imediatas, tais como o aumento da eficiência energética das fornalhas [1]. Este trabalho realizado na Galp Energia S.A. teve como objectivo principal a optimização energética da Unidade de Desalfatação do Propano da Fábrica de Óleos Base. Esta optimização baseou-se no aproveitamento energético da corrente de fundo da coluna de rectificação T2003C com uma potência calorífica de 2,79 Gcal/h. Após levantamento de todas as variáveis do processo relativas a esta unidade, especialmente a potência calorífica das correntes envolvidas chegou-se á conclusão que a fornalha H2101 poderá ser substituída por dois permutadores, reduzindo desta forma os consumos energéticos. Pois a corrente de fundo da coluna T2003 com uma potência calorífica 2,79 Gcal/h poderá permutar calor com a corrente da mistura asfalto com propano, fazendo com que esta atinja temperatura superior à obtida com a fornalha em funcionamento. A análise económica ao consumo e respectivo custo do fuelóleo na fornalha para o período de um ano foi realizada, sendo o seu custo de combustível de 611.396,00 €. O valor da aquisição dos permutadores é 86.355,97€, sendo rentável a alteração proposta neste projecto.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
As estruturas coladas são geralmente projetadas para que o adesivo seja essencialmente sujeito a esforços de corte, pois neste tipo de solicitação o adesivo apresenta melhores caraterísticas mecânicas. A avaliação do comportamento ao corte pode ser realizada com o adesivo no estado maciço ou como camada fina em juntas adesivas. Os métodos que permitem avaliar o comportamento ao corte, quer para o adesivo, quer para as juntas, são: o ensaio Iosipescu ou V-Notched beam shear method, o ensaio de borboleta ou Notched plate shear method (Arcan), o ensaio de torsão, o ensaio de tração numa junta de sobreposição simples e o ensaio Thick Adherend Shear Test (TAST). Os ensaios Arcan e Iosipescu, tal como o ensaio de torção, podem ser realizados em provetes de adesivo maciço ou em juntas. O ensaio de torção é pouco utilizado, porque a aplicação do esforço de corte exige dispositivos e equipamentos de ensaios complexos. Os ensaios Arcan e Iosipescu utilizam provetes com entalhes e podem introduzir alguma dificuldade na medição precisa das deformações. O ensaio de tração numa junta de sobreposição simples é um dos métodos mais usados para caraterizar uma junta adesiva, porque é um método simples, as juntas são de fácil fabrico e pode ser realizado em máquinas universais de ensaios mecânicos. Neste ensaio os aderentes estão sujeitos a uma solicitação de tração, enquanto a camada de adesivo está sujeita a esforços de corte combinados com esforços de arrancamento. Os esforços de arrancamento resultam da própria geometria da junta na qual existe um desalinhamento das forças de tração, mesmo quando são colocados calços (reguladores de espessura) nos locais de amarração. O ensaio TAST é dos mais populares para obtenção das propriedades ao corte, uma vez que tanto as ferramentas de ensaio como o fabrico dos provetes são relativamente simples. Este ensaio é realizado em junta sendo os substratos espessos e de aço que, devido à sua elevada rigidez, contribuem para um esforço de corte praticamente puro no adesivo. Neste trabalho realizou-se o projeto e a fabricação das ferramentas, gabarit e substratos necessários para a execução de provetes TAST e ensaios utilizando diferentes adesivos.
Resumo:
An experimental and numerical investigation into the shear strength behaviour of adhesive single lap joints (SLJs) was carried out in order to understand the effect of temperature on the joint strength. The adherend material used for the experimental tests was an aluminium alloy in the form of thin sheets, and the adhesive used was a high-strength high temperature epoxy. Tensile tests as a function of temperature were performed and numerical predictions based on the use of a bilinear cohesive damage model were obtained. It is shown that at temperatures below Tg, the lap shear strength of SLJs increased, while at temperatures above Tg, a drastic drop in the lap shear strength was observed. Comparison between the experimental and numerical maximum loads representing the strength of the joints shows a reasonably good agreement.
Resumo:
Orientado pela Professora Doutora Maria Clara Ribeiro
Resumo:
Mestrado em Engenharia Química – Ramo Optimização Energética na Indústria Química
Resumo:
Mestrado em Engenharia Mecânica- Energia
Resumo:
Introdução: Entende-se por fitoterapia a terapêutica caracterizada pelo uso de plantas medicinais nas diferentes formas farmacêuticas com finalidade terapêutica, usada assim para prevenir, atenuar ou curar um estado patológico. Objetivos: Caracterizar a utilização de plantas aromáticas e medicinais (PAM´s), medicamentos e produtos à base de plantas pela população do concelho de Bragança, conhecer a fonte de indicação deste tipo de produtos, apurar a relação entre a fonte de indicação e o estado de saúde após a utilização, verificar a sua correta utilização relativa à indicação terapêutica, modo e frequência de utilização, identificar potenciais interacções medicamentosas, averiguar se os utentes informam o médico do seu uso, investigar a ocorrência de efeitos adversos e apurar a relação entre os efeitos adversos ocorridos e o género dos inquiridos. Métodos: Trata-se de um estudo observacional analítico-transversal. Nele participaram 404 indivíduos de ambos os géneros e com idades compreendidas entre os 18 e os 89 anos. A recolha de dados foi realizada entre os meses de abril e junho de 2014, através de um questionário estruturado de autopreenchimento, formado por 30 perguntas. Após a recolha dos dados procedeu-se à leitura óptica dos questionários, sendo os dados posteriormente exportados para SPSS permitindo assim o tratamento dos mesmos. Para análise estatística utilizou-se o teste do qui-quadrado considerando o nível de significância p <0,05. Resultados: Verificou-se que 53,7% dos inquiridos recorre terapeuticamente a PAM´s que inclui principalmente o uso de cidreira e camomila enquanto 33,8% faz uso de medicamentos e/ou produtos àbase de plantas nomeadamente Valdispert e Daflon. A utilização de PAM,s é motivada por autoconhecimento e indicação de familiares, amigos e vizinhos. Já os medicamentos e/ou produtos à base de plantas são utilizados maioritariamente por prescrição médica e indicação na farmácia. A ocorrência de efeitos indesejáveis foi sentida unicamente com a utilização de PAM´s e em pequena escala. Conclusão: O recurso a este tipo de produtos é uma prática bastante comum entre os moradores do concelho de Bragança, que utilizam uma grande diversidade de plantas e produtos à base de plantas para um variado leque de indicações terapêuticas, apontando a percentagem de respostas para um conhecimento dos seus efeitos terapêuticos.
Resumo:
A necessidade de utilizar métodos de ligação entre componentes de forma mais rápida, eficaz e com melhores resultados, tem causado a crescente utilização das juntas adesivas, em detrimento dos métodos tradicionais de ligação tais como a soldadura, brasagem, ligações aparafusadas e rebitadas. A utilização das juntas adesivas tem vindo a aumentar em diversas aplicações industriais por estas apresentarem vantagens das quais se destacam a redução de peso, redução de concentrações de tensões e facilidade de fabrico. No entanto, também apresentam desvantagens, como a necessidade de preparação das juntas e o descentramento da carga aplicada que provoca efeitos de flexão, os quais dão origem a tensões normais na direcção da espessura do adesivo (tensões de arrancamento), afectando assim a resistência da junta. A combinação da ligação adesiva com a soldadura por pontos permite algumas vantagens em comparação com as juntas adesivas tradicionais como a maior resistência, aumento da rigidez, melhor resistência ao corte e arrancamento e também à fadiga. Neste trabalho é apresentado um estudo experimental e numérico de juntas de sobreposição simples adesivas e híbridas (adesivas-soldadas). Os adesivos utilizados são o Araldite AV138®, apresentado como sendo frágil, e os adesivos Araldite 2015® e Sikaforce® 7752, intitulados como adesivos dúcteis. Foram considerados substratos de aço (C45E) em juntas com diferentes comprimentos de sobreposição ( ), que foram sujeitas a esforços de tracção. Foi realizada uma análise dos valores experimentais e efectuada uma comparação destes valores com os resultados obtidos por Elementos Finitos (EF) no software ABAQUS®, que incluiu uma análise de tensões na camada de adesivo e previsão do comportamento das juntas por Modelos de Dano Coesivo (MDC). A análise por MDC permitiu obter os modos de rotura, as curvas força-deslocamento e a resistência das juntas com bastante precisão, com excepção das juntas coladas com o adesivo Sikaforce® 7752. Estes resultados permitiram validar a técnica de modelação proposta para as juntas coladas e híbridas, o que representa uma base para posterior aplicação desta técnica em projecto, com as vantagens decorrentes da redução do tempo de projecto e maior facilidade de optimização.
Resumo:
A metrologia na saúde tem um elevado grau de importância no quotidiano hospitalar dado que muitas decisões são tomadas com base em medições. Além disso, a constante evolução tecnológica na área da saúde e o número crescente de parâmetros fisiológicos dos equipamentos médicos exige a constante preocupação com o controlo metrológico. Assim, o funcionamento eficiente destes poderá contribuir para a segurança, uma melhor e mais rápida recuperação do doente e, consequentemente, um aumento do tempo de vida do equipamento, o que por sua vez se reflete numa maior economia de custos. A otimização de protocolos de metrologia em saúde, a elaboração de planos de controlo para validação de equipamentos médicos-hospitalares, a sensibilização de profissionais de saúde para o controlo metrológico, assim como o conhecimento das aplicações informáticas da organização são essenciais para uma eficaz gestão da manutenção hospitalar. O Serviço de Instalações e Equipamentos do Centro Hospitalar do Tâmega e Sousa, trabalha no sentido de assegurar uma resposta rápida, otimizada e eficiente para satisfazer as necessidades hospitalares através da aplicação de metodologias e ferramentas da qualidade destinadas à metrologia em saúde. Assim, o objetivo principal deste trabalho é apresentar metodologias e ferramentas aplicadas no controlo de parâmetros de equipamentos médico-hospitalares tais como, dispositivos de infusão, monitores de sinais vitais, eletrocardiógrafos, cardiotocógrafos, desfibrilhadores, incubadoras, aparelhos de fototerapia, bem como, o processo de gestão da manutenção aplicado pelo Serviço de Instalações e Equipamentos. Neste sentido foi possível demonstrar que o controlo metrológico é de extrema importância para uma instituição hospitalar.