9 resultados para ventral mesenchymal pad
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Human mesenchymal stem/stromal cells (MSCs) have received considerable attention in the field of cell-based therapies due to their high differentiation potential and ability to modulate immune responses. However, since these cells can only be isolated in very low quantities, successful realization of these therapies requires MSCs ex-vivo expansion to achieve relevant cell doses. The metabolic activity is one of the parameters often monitored during MSCs cultivation by using expensive multi-analytical methods, some of them time-consuming. The present work evaluates the use of mid-infrared (MIR) spectroscopy, through rapid and economic high-throughput analyses associated to multivariate data analysis, to monitor three different MSCs cultivation runs conducted in spinner flasks, under xeno-free culture conditions, which differ in the type of microcarriers used and the culture feeding strategy applied. After evaluating diverse spectral preprocessing techniques, the optimized partial least square (PLS) regression models based on the MIR spectra to estimate the glucose, lactate and ammonia concentrations yielded high coefficients of determination (R2 ≥ 0.98, ≥0.98, and ≥0.94, respectively) and low prediction errors (RMSECV ≤ 4.7%, ≤4.4% and ≤5.7%, respectively). Besides PLS models valid for specific expansion protocols, a robust model simultaneously valid for the three processes was also built for predicting glucose, lactate and ammonia, yielding a R2 of 0.95, 0.97 and 0.86, and a RMSECV of 0.33, 0.57, and 0.09 mM, respectively. Therefore, MIR spectroscopy combined with multivariate data analysis represents a promising tool for both optimization and control of MSCs expansion processes.
Resumo:
Peripheral arterial disease (PAD) as a high incidence in general population and 12% to 20% of population with more than 60 years has already clinical symptoms, such as intermittent claudication (IC), pain, loss of strength and functional incapacity. There are already some studies who refer the possible positive effects of physical exercise in functional consequences of PAD.
Resumo:
O risco de doença cardiovascular duplica exponencialmente por cada aumento de 20 mmHg na PAS ou 10mmHg na PAD. Benefícios do exercício físico: melhora a depressão; melhora a autoconfiança e a auto-estima; melhora a ansiedade e o stress; melhora capacidades cognitivas; eventual auxílio na evicção de toxicomanias; baixa a pressão arterial; melhora o perfil lipídico: HDL, Triglicéridos e LDL; melhora a sensibilidade à insulina; diminui o stress; baixa o peso (sobretudo à custa da massa gorda); promove a manutenção ou aumento de massa muscular; acção modeladora do apetite; aumenta o metabolismo em repouso após a actividade •Aumenta a termogénese alimentar; aumenta o tónus muscular e o consumo calórico em repouso; aumenta a força; pode motivar para outros comportamentos saudáveis (ex: tabaco); menor incidência de infecções; menor incidência de neoplasias; previne a osteoporose aumentando a massa óssea ou atrasando a sua perda; atrasa certos processos do envelhecimento.
Resumo:
Peripheral arterial disease (PAD) as a high incidence in general population and 12% to 20% of population with more than 60 years has already clinical symptoms, such as intermittent claudication (IC), pain, loss of strength and functional incapacity. There are already some studies that refer the possible positive effects of physical exercise in functional consequences of PAD. The purpose of this study was to verify the results of a home-based (HB) weekly supervised physical exercise program in patients with IC in consequence of PAD in lower limbs, and observe the medium number of diary steps walked by the subjects of our study.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Introdução – A medição da pressão arterial (PA), utilizando dispositivos automáticos, é frequentemente realizada na prática clínica e na automedição, permitindo adquirir informação fiável para o diagnóstico, controlo e tratamento da hipertensão arterial. Porém, muitos dos dispositivos automáticos disponíveis no mercado não estão validados segundo protocolos existentes para o efeito. O objetivo do estudo foi confirmar a validação do dispositivo de medição automática da PA, OMRON® M6 Comfort, segundo o Protocolo Internacional da European Society of Hypertension (ESH), de 2010, para a validação de dispositivos de medição automática da PA em adultos. Metodologia – Foram estudados 33 indivíduos, aos quais foram realizadas 9 medições sequenciais da PA, no braço esquerdo, com um esfignomanómetro aneróide alternando com o dispositivo automático. Seguidamente avaliaram-se as diferenças entre os valores obtidos pelos dispositivos para a pressão arterial sistólica (PAS) e diastólica (PAD), classificando-as em três níveis (≤ 5, ≤ 10 ou ≤ 15 mmHg). O número das diferenças em cada nível foi comparado ao requerido pelo Protocolo (fase 1.1). Para cada sujeito foi ainda determinado o número de diferenças com valores ≤ 5 mmHg. Pelo menos 24 dos 33 indivíduos devem ter 2 ou 3 diferenças com valores ≤ 5 mmHg e no máximo 3 dos 33 indivíduos podem apresentar as 3 diferenças com valores > 5 mmHg (fase 1.2). Resultados – O dispositivo OMRON® M6 Comfort foi aprovado nas fases 1.1 e 1.2 para a PAS e PAD. A média das diferenças entre as medições da PA, determinada pelos dispositivos automático e manual, foi de -0,82 ± 5,62 mmHg para a PAS e 2,14 ± 5,15 mmHg para a PAD. Considerações Finais – O dispositivo OMRON® M6 Comfort é válido para a medição da PA em adultos, de acordo com o Protocolo Internacional da ESH, de 2010. - ABSTRACT - Introduction – The measurement of blood pressure (BP) using automatic devices is often performed in clinical practice and self-measurement allowing the acquisition of reliable information for the diagnosis, monitoring and treatment of hypertension. However not all of the automated devices available in the market are validated in accordance with the existing protocols for this purpose. The purpose of this study was to confirm the validation of the automatic measuring device of the BP, OMRON® M6 Comfort, according to the “European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults”. Methodology – The study involved 33 subjects, in each one of them, 9 sequential measurements of BP were performed, in the left arm, with the aneroid sphygmomanometer alternating with the automatic device. Afterwards, the differences on the values obtained by the different devices were evaluated, for systolic blood pressure (SBP) and diastolic (DBP), and these differences were then classified into three levels (≤ 5, ≤ 10 or ≤ 15 mmHg). The number of differences at each level was compared to the number required by the protocol (phase 1.1). For each subject the number of differences with values ≤ 5 mmHg was also determined. At least 24 of the 33 subjects should have 2 or 3 differences with values ≤ 5 mmHg and a maximum of 3 of the 33 subjects may have all differences with values > 5 mmHg (phase 1.2). Results – The device OMRON M6 Comfort ® was approved in phases 1.1 and 1.2 for SBP and DBP. The average difference between measurements of BP, as determined by automatic and manual devices, was -0.82 ± 5.62 mmHg for SBP and 2.14 ± 5.15 mmHg for DBP. Conclusion – The device OMRON M6 Comfort® is valid for measuring BP in adults, according to the ESH International Protocol of 2010.
Resumo:
Introdução: O cancro retal continua a ser um dos principais problemas de saúde a nível mundial, sendo a toxicidade gastro-intestinal e génito-urinária os efeitos tardios da radioterapia mais reportados. A utilização da Belly-Board para minimizar essa toxicidade, reduzindo o volume de bexiga e intestino delgado irradiados é recomendada. No entanto, o protocolo mais adequado para o volume vesical nestes doentes é ainda tema de controvérsia. Objetivo: Avaliar a influência do volume vesical na dose recebida na bexiga e no PTV, em doentes com tumor de reto, posicionados em decúbito ventral, com belly-board. Materiais e Métodos: 38 doentes com tumor de reto tratados no CHBM, agrupados em dois grupos: o 1º grupo, com 19 doentes que realizaram tratamento com bexiga cheia e o 2º grupo, com 19 doentes que realizaram tratamento com bexiga vazia. Os dados foram obtidos através dos HDV’s e foram comparadas as doses máximas no PTV e a percentagem de volume de bexiga que recebe 50Gy. Foi utilizado o teste estatístico U-Mann Whitney com um nível de significância de 0,05. A hipótese de pesquisa deste estudo propõe que os dois grupos diferem significativamente entre si e a hipótese nula propõe que os dois grupos não diferem significativamente entre si, para ambas as variáveis. Resultados: Não se observaram diferenças estatisticamente significativas entre os grupos no que diz respeito à dose máxima no PTV. No que se refere à percentagem de volume de bexiga que recebe 50Gy verificaram-se diferenças estatisticamente significativas, tendo o grupo de doentes que realizaram tratamento com bexiga cheia apresentado valores mais baixos. Conclusões: Este estudo demonstrou o benefício da utilização do protocolo de bexiga cheia em doentes com tumor de reto tratados com belly-board, na diminuição da percentagem de volume de bexiga que recebe 50Gy.
Resumo:
O número de bebés que nascem prematuros tem vindo a aumentar. É indiscutível a importância dos avanços tecnológicos e da pesquisa nas Unidades de Cuidados Intensivos de Neonatologia (UCIN), sendo essencial o papel desempenhado pelos fisioterapeutas nos cuidados prestados a estes bebés. As suas potencialidades só se desenvolvem na medida em que o bebé encontra estimulação e posicionamento adequado. Realizou‑se um estudo piloto na UCIN do Centro Hospitalar Lisboa Norte (CHLN), no período de julho de 2011 a março de 2012, em que se pretendeu avaliar o efeito de um programa de fisioterapia na estabilização do prematuro. Este programa consistiu em posicionar o prematuro em decúbito dorsal, lateral direito e lateral esquerdo e decúbito ventral, permanecendo em cada posição 5 minutos. O objetivo foi avaliar, durante a permanência do bebé na UCIN, a alteração nos seguintes parâmetros: frequência cardíaca (FC) e saturação de oxigénio (SatO2), antes e depois do tratamento. A amostra por conveniência incluiu no estudo 30 bebés prematuros, sendo 13 do género feminino e 17 do género masculino, que obedeceram a critérios específicos de inclusão. Para verificar as variáveis fisiológicas FC e SatO2 foi utilizado um Oxímetro de Pulso BCI 3401. Verificou‑se que a FC diminui e a SatO2 aumentou entre a primeira avaliação e a segunda avaliação, para a amostra total, assim como para os sujeitos do género feminino e os sujeitos do género masculino, para α = 0,05 e valor p≤0,001. Contudo, a diferença entre as médias dos dois momentos de avaliação da FC e da SatO2, em função do género, não revelaram diferenças estatisticamente significativas. Em conclusão, o estudo sugere que o programa de fisioterapia promove a melhoria da SatO2 e diminuição da FC, promovendo uma melhoria da estabilização do prematuro.
Resumo:
Chitosan biocompatibility and biodegradability properties make this biopolymer promising for the development of advanced internal fixation devices for orthopedic applications. This work presents a detailed study on the production and characterization of three dimensional (3D) dense, non-porous, chitosan-based structures, with the ability to be processed in different shapes, and also with high strength and stiffness. Such features are crucial for the application of such 3D structures as bioabsorbable implantable devices. The influence of chitosan's molecular weight and the addition of one plasticizer (glycerol) on 3D dense chitosan-based products' biomechanical properties were explored. Several specimens were produced and in vitro studies were performed in order to assess the cytotoxicity of these specimens and their physical behavior throughout the enzymatic degradation experiments. The results point out that glycerol does not impact on cytotoxicity and has a high impact in improving mechanical properties, both elasticity and compressive strength. In addition, human mesenchymal stem/stromal cells (MSC) were used as an ex-vivo model to study cell adhesion and proliferation on these structures, showing promising results with fold increase values in total cell number similar to the ones obtained in standard cell culture flasks. (C) 2014 Elsevier Ltd. All rights reserved.