23 resultados para tomografia computadorizada por emissão

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The formation of amyloid structures is a neuropathological feature that characterizes several neurodegenerative disorders, such as Alzheimer´s and Parkinson´s disease. Up to now, the definitive diagnosis of these diseases can only be accomplished by immunostaining of post mortem brain tissues with dyes such Thioflavin T and congo red. Aiming at early in vivo diagnosis of Alzheimer´s disease (AD), several amyloid-avid radioprobes have been developed for b-amyloid imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The aim of this paper is to present a perspective of the available amyloid imaging agents, special those that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A imagem de perfusão do miocárdio por tomografia computorizada de emissão de fotão único (SPECT, do acrónimo inglês Single Photon Emission Computed Tomography) é um dos exames complementares de diagnóstico mais indicados na cardiologia clínica. Os dois agentes tecneciados mais utilizados são o 99mTc-tetrofosmina e o 99mTc-sestamibi. Estes permitem avaliar a distribuição do fluxo sanguíneo no músculo cardíaco. O mecanismo de fixação é idêntico nos dois radiofármacos (RF’s). São excretados, do organismo, a partir do sistema hepatobiliar para o duodeno e para o intestino. Assim, o RF está presente tanto no coração como nos órgãos adjacentes. O coração encontra-se localizado sobre o diafragma, logo acima do lobo esquerdo do fígado e nas proximidades do estômago. Deste modo, os fotões difusos provenientes desses órgãos podem interferir com a interpretação das imagens SPECT, principalmente na parede inferior do ventrículo esquerdo, traduzindo-se na redução da razão alvo-fundo e na qualidade da imagem. Deste modo, a sensibilidade e a especificidade da Cintigrafia de Perfusão do Miocárdio (CPM) diminuem. Têm sido descritos na literatura vários métodos e técnicas para minimizar o efeito da actividade extra-miocárdica, como: a aquisição de imagens mais tardias, a ingestão de líquidos ou alimentos ricos em lípidos. Outras técnicas apontam para a alteração do posicionamento do paciente durante a aquisição. Assim, o objectivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições de exames provocadas pela interferência de actividade extra-miocárdica.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Área de especialização: Tomografia por emissão de positrões

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – A ausência de um ciclotrão para produção da 2-[18F]Flúor-2-deoxi-D-glucose (18F-FDG) é, actualmente, uma realidade para a maior parte dos centros onde se realizam exames de Tomografia por Emissão de Positrões (TEP), sendo importante garantir a qualidade deste radiofármaco desde o momento da sua síntese até à administração ao doente. O objectivo do estudo é demonstrar a influência dos parâmetros temperatura, pH, concentração radioactiva (CR) e tempo na pureza radioquímica da 18F-FDG. Metodologia – Analisou-se o pH e a pureza radioquímica [por cromatografia em camada fina (CCF)] de seis amostras de 18F-FDG com diferentes CR e em diferentes tempos e temperaturas. Resultados – Registou-se um aumento da percentagem de 18F- aquando do aumento do tempo. Contudo, os resultados não comprovam que a diluição das amostras diminui a degradação do 18F-FDG. No entanto, comparando apenas as amostras diluídas (185 e 740 MBq/ml), observa-se uma relação positiva entre a CR e a percentagem de 18F-. Verificou-se ainda um aumento da percentagem de 18F- nas temperaturas mais elevadas. Conclusão – Sugere-se a diluição das amostras de 18F-FDG e que o tempo de armazenamento não seja muito longo. As amostras devem ainda encontrar-se a temperatura e pH estáveis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção Contra Radiações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – O cancro de mama é a principal causa de morte por cancro na população feminina portuguesa. Assim, pretende-se descrever sucintamente o percurso de uma paciente com tumor de mama, evidenciando a interligação entre algumas áreas das tecnologias da saúde. Metodologia – Selecionou-se um caso clínico de uma paciente com cancro de mama e recorreu-se à pesquisa bibliográfica de forma a apoiar ou refutar os resultados obtidos com o referido caso clínico. Resultados e discussão de resultados – Em 1996 foi diagnosticado à paciente um carcinoma ductal da mama esquerda e posteriormente, em 2011, foi diagnosticada uma metástase do carcinoma mamário com padrão mucinoso. Neste caso, bem como em todos os tumores de mama, foi realizada uma abordagem multidisciplinar envolvendo diferentes áreas das tecnologias da saúde. Para deteção e diagnóstico do cancro de mama são utilizadas a mamografia e a ultrassonografia. Para casos de re-estadiamento e monitorização da terapêutica devem ser utilizadas a tomografia por emissão de positrões (TEP) e a ressonância magnética mamária. No que se refere à terapêutica, neste tipo de tumores recorre-se à cirurgia, à radioterapia e à quimioterapia. ABSTRACT - Introduction – The breast cancer is the main cause of death by cancer in the Portuguese female population. We intend to describe briefly the pathway of a patient with breast cancer, highlighting the connection between some of the health technology areas. Methodology – It was selected a clinical case of a patient with breast cancer and it was used a literature research to support or refute the results obtained with the mentioned clinical case. Results and discussion – In 1996, it was diagnosed to the patient a ductal carcinoma of the left breast and in 2011 it was diagnosed a breast metastases. In this case, as well as other breast tumours, it was done a multidisciplinary approach involving different areas of health technologies. For detection and diagnose of breast cancer it’s used the mammography and ultrasound. For cases of re-staging and treatment monitoring it should be used positron emission tomography and magnetic resonance imaging of the breast. Regarding the therapy approach, in this type of tumours, it is used surgery, radiotherapy and chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Área de especialização: Tomografia por Emissão de Positrões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica Ramo de processos químicos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Contabilidade e Gestão de Instituições Financeiras

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – A tomografia de emissão de fotão simples sincronizada com o sinal eletrocardiográfico (Gated-SPECT) é essencial para a avaliação conjunta da perfusão e da função ventricular esquerda (VE) do miocárdio. Objetivo – Investigar a relação entre a função VE e o índice de captação (IC) miocárdio/pulmão direito (M/PD) e M/P esquerdo (M/PE) nos estudos Gated-SPECT com 99mTc-Tetrofosmina. Metodologia – Amostra de 32 pacientes que realizaram estudos Gated-SPECT por indicação clínica, sendo subdividida em dois grupos: Grupo I (GI) – pacientes com a informação clínica de enfarte agudo do miocárdio (EAM); Grupo II (GII) – pacientes com a informação clínica de isquemia. Por cada paciente adquiriram-se imagens estáticas torácico-abdominais e dois estudos Gated-SPECT do miocárdio (protocolo de um dia esforço/repouso). Nas imagens estáticas definiram-se regiões de interesse (Regions of interest – ROI) para calcular os IC. Nos estudos Gated-SPECT utilizou-se o software Quantitative Gated SPECT/Quantitative Perfusion SPECT para calcular a Fração de Ejeção do Ventrículo Esquerdo (FEVE). Efetuou-se análise estatística descritiva para caracterização da amostra. Aplicou-se o teste de Spearman para avaliar a correlação entre a FEVE e os IC por grupo de pacientes. O Teste de Willcoxon foi usado para comparar FEVE em repouso e em esforço. Resultados – Nos estudos Gated-SPECT em esforço não se verificou correlação estatisticamente significativa entre a FEVE e os IC, para GI e GII; em repouso existe correlação positiva estatisticamente significativa entre a FEVE e os IC, para GI; para GII não se verificou correlação. Na comparação dos valores de FEVE em esforço e repouso nos dois grupos constatou-se a existência de diferenças estatisticamente significativas, sendo a FEVE em Esforço

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões