15 resultados para municipal wastewater
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Wastewater from cork processing industry present high levels of organic and phenolic compounds, such as tannins, with a low biodegradability and a significant toxicity. These compounds are not readily removed by conventional municipal wastewater treatment, which is largely based on primary sedimentation followed by biological treatment. The purpose of this work is to study the biodegradability of different cork wastewater fractions, obtained through membrane separation, in order to assess its potential for biological treatment and having in view its valorisation through tannins recovery, which could be applied in other industries. Various ultrafiltration and nanofiltration membranes where used, with molecular weight cut-offs (MWCO) ranging from 0.125 to 91 kDa. The wastewater and the different permeated fractions were analyzed in terms of Total Organic Carbon (TOC), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Total Phenols (TP), Tannins, Color, pH and Conductivity. Results for the wastewater shown that it is characterized by a high organic content (670.5-1056.8 mg TOC/L, 2285-2604 mg COD/L, 1000-1225 mg BOD/L), a relatively low biodegradability (0.35-0.38 for BODs/COD and 0.44-0.47 for BOD20/COD) and a high content of phenols (360-410 mg tannic acid/L) and tannins (250-270 mg tannic acid/L). The results for the wastewater fractions shown a general decrease on the pollutant content of permeates, and an increase of its biodegradability, with the decrease of the membrane MWCO applied. Particularly, the permeated fraction from the membrane MWCO of 3.8 kDa, presented a favourable index of biodegradability (0.8) and a minimized phenols toxicity that enables it to undergo a biological treatment and so, to be treated in a municipal wastewater treatment plant. Also, within the perspective of valorisation, the rejected fraction obtained through this membrane MWCO may have a significant potential for tannins recovery. Permeated fractions from membranes with MWCO lower than 3.8 kDa, presented a particularly significant decline of organic matter and phenols, enabling this permeates to be reused in the cork processing and so, representing an interesting perspective of zero discharge for the cork industry, with evident environmental and economic advantages. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil, na Área de Especialização de Hidráulica
Resumo:
A requalificação e a modernização do parque escolar do 1º ciclo de ensino básico e do pré-escolar é uma competência atribuída aos municipios e implica a existência de um plano de intervenção e a construção de novos centros escolares, bem como a ampliação e requalificação dos edifícios existentes.Procura-se com esta dissertação e a partir de uma situação específica associada a empreendimentos escolares de iniciativa municipal, abordar a temática da gestão de projectos.A dissertação ora apresentada encontra-se estruturada em cinco partes essenciais: A primeira, corresponde ao estado actual, abordando as metodologias da gestão de projectos mais usadas. A segunda, parte do conceito de ciclo de vida de um projecto, descreve o modelo de fases sucessivas e integra-o no modelo de grupos de processos. A terceira, apresenta uma proposta de modelo de gestão de projectos gerado por distintos processos e inclui um guia de referência e de técnicas. A quarta, descreve os processos de gestão dos custos e determina com base num conjunto de projectos analisados: i) indicadores específicos, para uso em estimação de custos; ii) funções lineares, que relacionam características físicas de um edifício escolar com custo estimado de execução; iii) estrutura de custos, para obter informação valiosa do ponto de vista técnico-económico no domínio da promoção deste tipo de empreendimentos. Finalmente a última, reúne as conclusões e aponta orientações futuras de pesquisa.Propõe-se, portanto, uma forma diferente de observar a gestão de projectos no âmbito da Administração Local, considerando-se a implementação do modelo de processos uma via para a obtenção de resultados mais rigorosos e participativos e ao mesmo tempo aponta-se para uma nova orientação sobre qualidade em gestão de projectos.
Resumo:
O presente trabalho tem como objectivo ser um elemento de reflexão do exercício das competências de fiscalização dos Municípios, no actual contexto legal (Decreto-Lei nº 555/99 de 16 de Dezembro na redacção que lhe foi conferida pela Lei nº 60/2007 de 4 de Setembro). Este regime jurídico que visa aligeirar os procedimentos de controlo prévio das operações urbanísticas vem, numa linha inovadora, remeter para um controlo “a posteriori” o controlo administrativo das operações urbanísticas promovidas por particulares. Os limites de intervenção da Administração, num quadro em que os interesses dos particulares e o interesse público têm por vezes objectivos distintos, fazem com que a actividade de fiscalização se manifeste de alguma dificuldade. O universo deste documento abrange os municípios da Área Metropolitana de Lisboa, num total de dezoito, com uma população residente de 2.830.867 habitantes. Espera-se que as conclusões obtidas sejam dinamizadoras de melhoria futura.
Resumo:
Este trabalho final de mestrado baseia-se no projecto de execução e remodelação de uma rede predial de abastecimento de água e de uma rede predial de drenagem de águas residuais domésticas de um edifício existente na localidade da Tapada das Mercês (freguesia de Algueirão - Mem Martins, Concelho de Sintra). Este prédio está dividido em dois pisos: o Mercado da Tapada das Mercês - Piso 0 - e a Casa da Juventude - Piso-1. Com este trabalho, respondeu-se a uma solicitação da Divisão de Projectos Municipais e da Divisão de Mercados da Câmara Municipal de Sintra e procurou-se: Melhorar o desempenho das redes existentes; Diminuir os custos de operação e manutenção dessas mesmas redes; Resolver o problema das infiltrações no tecto da Casa da Juventude, que está a afectar a rede de distribuição eléctrica perturbando o normal funcionamento desses serviços. Pretende-se também fornecer sugestões de melhoria do Regulamento -Decreto Regulamentar nº 23/95 e aumentar os meus conhecimentos nesta área, atendendo a que a minha formação base é em Vias de Comunicação e Transportes. A título de reflexão, propõe-se uma actualização em termos de materiais para o regulamento acima mencionado.
Resumo:
Nanofiltration process for the treatment/valorisation of cork processing wastewaters was studied. A DS-5 DK 20/40 (GE Water Technologies) nanofiltration membrane/module was used, having 2.09 m(2) of surface area. Hydraulic permeability was determined with pure water and the result was 5.2 L.h(-1).m(-2).bar(-1). The membrane presents a rejection of 51% and 99% for NaCl and MgSO4 salts, respectively. Two different types of regimes were used in the wastewaters filtration process, total recycling mode and concentration mode. The first filtration regime showed that the most favourable working transmembrane pressure was 7 bar working at 25 degrees C. For the concentration mode experiments it was observed a 30% decline of the permeate fluxes when a volumetric concentration factor of 5 was reached. The permeate COD, BOD5, colour and TOC rejection values remained well above the 90% value, which allows, therefore, the concentration of organic matter (namely the tannin fraction) in the concentrate stream that can be further used by other industries. The permeate characterization showed that it cannot be directly discharged to the environment as it does not fulfil the values of the Portuguese discharge legislation. However, the permeate stream can be recycled to the process (boiling tanks) as it presents no colour and low TOC (< 60 ppm) or if wastewater discharge is envisaged we have observed that the permeate biodegradability is higher than 0.5, which renders conventional wastewater treatments feasible.
Resumo:
A deposição de resíduos sólidos urbanos (RSU) em aterros sanitários (AS) tem uma dimensão que necessita de uma atenção especial por parte da sociedade. Deste acto podem resultar situações gravosas para o meio ambiente se não forem tomadas as medidas correctas. Um dos pontos que necessita de uma particular atenção é o tratamento das águas lixiviantes dos aterros sanitários, uma vez que estas apresentam geralmente cargas altamente poluentes. O presente trabalho apresenta a estrutura de um aterro sanitário, definindo os seus princípios de funcionamento, bem como as principais características a ter em consideração para a sua concepção e construção. É ainda abordada a composição dos resíduos sólidos produzidos em Portugal de acordo com (1) e as características quantitativas e qualitativas do lixiviado produzido por um AS. São apresentados os sistemas tratamento convencionais, biológicos e físico-químicos, mais utilizados em Portugal para o tratamento de águas lixiviantes, relacionando as problemáticas e as limitações associadas a cada um deles. É ainda apresentado o tratamento combinado de águas lixiviantes com águas residuais e a recirculação de lixiviado no sistema de tratamento, assim como algumas das vantagens associadas a estas práticas. Tendo por base, uma situação real, avalia-se um caso de estudo, que visa a avaliação do funcionamento da estação de pré-tratamento das águas lixiviantes produzidas no aterro sanitário do ecoparque de Palmela, tendo em consideração o facto de este tratamento ser realizado em combinação com o tratamento de águas residuais urbanas. A avaliação do funcionamento da estação de pré-tratamento de águas lixiviantes (EPTAL) é realizada de acordo com os dados fornecidos nos relatórios elaborados pela empresa LUSÁGUA, que apresentam os valores das cargas poluentes medidos à entrada e saída da EPTAL, verificando com estes dados se os valores limite de emissão medidos à saída da EPTAL são respeitados. São ainda propostas algumas alterações baseadas em pareceres técnicos que acompanham os relatórios elaborados pela LUSÁGUA e um estudo elaborada pela ECOserviços em Fevereiro de 2010 onde se obtêm eficiências de etapas de tratamentos com base em testes laboratoriais e testes realizados na própria EPTAL.
Resumo:
Cork processing involves a boiling step to make the cork softer, which consumes a high volume of water and generates a wastewater with a high organic content, rich in tannins. An assessment of the final wastewater characteristics and of the boiling water composition along the boiling process was performed. The parameters studied were pH, color, total organic carbon (TOC), chemical and biochemical oxygen demands (COD, BOD5, BOD20), total suspended solids (TSS), total phenols and tannins (TP, TT). It was observed that the water solutes extraction power is significantly reduced for higher quantities of cork processed. Valid relationships between parameters were established not only envisaging wastewater characterization but also to provide an important tool for wastewater monitoring and for process control/optimization. Boiling water biodegradability presented decreasing values with the increase of cork processed and for the final wastewater its value is always lower than 0.5, indicating that these wastewaters are very difficult to treat by biological processes. The biodegradability was associated with the increase of tannin content that can rise up to 0.7 g/L. These compounds can be used by other industries when concentrated and the clarified wastewater can be reused, which is a potential asset in this wastewater treatment.
Resumo:
Relatório de Estágio para obtenção de grau de Mestre em Engenharia Civil Perfil de Edificações
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
A batalha é geralmente considerada como um dos géneros mais característicos da literatura organística ibérica do Barroco. Paradoxalmente é, de todas os géneros da música de órgão peninsular, aquele acerca do qual se possuem menos dados sobre a prática interpretativa. A informação que se pode obter a partir da generalidade dos textos seiscentistas sobre música de tecla, aplica-se sobretudo à interpretação das obras contrapontísticas, deixando em aberto muitas questões relacionadas com o carácter eminentemente descritivo das batalhas. Por outro lado, é também interessante verificar que algumas das mais convincentes interpretações de batalhas que actualmente escutamos são aquelas que resultam de uma leitura menos literal do texto musical e de uma intenção clara de sublinhar o seu carácter descritivo. A informação extraída da Batalha famoza (presente no manuscrito MM 43 da Biblioteca Pública Municipal do Porto) e apresentada ao longo deste texto parece pôr em evidência o apelo que a execução das batalhas fazia a um esforço interpretativo por parte do organista, não só através da utilização de recursos específicos do órgão ibérico, mas também mediante o emprego de uma ornamentação mais livre que pusesse em evidência o carácter descritivo daquele género musical.
Resumo:
Filamentous fungi from genus Aspergillus were previously detected in wastewater treatment plants (WWTP) as being Aspergillus flavus (A. flavus), an important toxigenic fungus producing aflatoxins. This study aimed to determine occupational exposure adverse effects due to fungal contamination produced by A. flavus complex in two Portuguese WWTP using conventional and molecular methodologies. Air samples from two WWTP were collected at 1 m height through impaction method. Surface samples were collected by swabbing surfaces of the same indoor sites. After counting A. flavus and identification, detection of aflatoxin production was ensured through inoculation of seven inoculates in coconut-milk agar. Plates were examined under long-wave ultraviolet (UV; 365 nm) illumination to search for the presence of fluorescence in the growing colonies. To apply molecular methods, air samples were also collected using the impinger method. Samples were collected and collection liquid was subsequently used for DNA extraction. Molecular identification of A. flavus was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR detection system (Corbett). Among the Aspergillus genus, the species that were more abundant in air samples from both WWTP were Aspergillus versicolor (38%), Aspergillus candidus (29.1%), and Aspergillus sydowii (12.7%). However, the most commonly species found on surfaces were A. flavus (47.3%), Aspergillus fumigatus (34.4%), and Aspergillus sydowii (10.8%). Aspergillus flavus isolates that were inoculated in coconut agar medium were not identified as toxigenic strains and were not detected by RT-PCR in any of the analyzed samples from both plants. Data in this study indicate the need for monitoring fungal contamination in this setting. Although toxigenic strains were not detected from A. flavus complex, one cannot disregard the eventual presence and potential toxicity of aflatoxins.
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia na Área de Especialização em Vias de Comunicação e Transportes
Resumo:
The concerns on metals in urban wastewater treatment plants (WWTPs) are mainly related to its contents in discharges to environment, namely in the final effluent and in the sludge produced. In the near future, more restrictive limits will be imposed to final effluents, due to the recent guidelines of the European Water Framework Directive (EUWFD). Concerning the sludge, at least seven metals (Cd, Cr, Cu, Hg, Ni, Pb and Zn) have been regulated in different countries, four of which were classified by EUWFD as priority substances and two of which were also classified as hazardous substances. Although WWTPs are not designed to remove metals, the study of metals behaviour in these systems is a crucial issue to develop predictive models that can help more effectively the regulation of pre-treatment requirements and contribute to optimize the systems to get more acceptable metal concentrations in its discharges. Relevant data have been published in the literature in recent decades concerning the occurrence/fate/behaviour of metals in WWTPs. However, the information is dispersed and not standardized in terms of parameters for comparing results. This work provides a critical review on this issue through a careful systematization, in tables and graphs, of the results reported in the literature, which allows its comparison and so its analysis, in order to conclude about the state of the art in this field. A summary of the main consensus, divergences and constraints found, as well as some recommendations, is presented as conclusions, aiming to contribute to a more concerted action of future research. © 2015, Islamic Azad University (IAU).
Resumo: