38 resultados para indoor temperature
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
This paper presents a distributed model predictive control (DMPC) for indoor thermal comfort that simultaneously optimizes the consumption of a limited shared energy resource. The control objective of each subsystem is to minimize the heating/cooling energy cost while maintaining the indoor temperature and used power inside bounds. In a distributed coordinated environment, the control uses multiple dynamically decoupled agents (one for each subsystem/house) aiming to achieve satisfaction of coupling constraints. According to the hourly power demand profile, each house assigns a priority level that indicates how much is willing to bid in auction for consume the limited clean resource. This procedure allows the bidding value vary hourly and consequently, the agents order to access to the clean energy also varies. Despite of power constraints, all houses have also thermal comfort constraints that must be fulfilled. The system is simulated with several houses in a distributed environment.
Resumo:
This paper presents a distributed predictive control methodology for indoor thermal comfort that optimizes the consumption of a limited shared energy resource using an integrated demand-side management approach that involves a power price auction and an appliance loads allocation scheme. The control objective for each subsystem (house or building) aims to minimize the energy cost while maintaining the indoor temperature inside comfort limits. In a distributed coordinated multi-agent ecosystem, each house or building control agent achieves its objectives while sharing, among them, the available energy through the introduction of particular coupling constraints in their underlying optimization problem. Coordination is maintained by a daily green energy auction bring in a demand-side management approach. Also the implemented distributed MPC algorithm is described and validated with simulation studies.
Resumo:
Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).
Resumo:
The study’s main purpose was the assessment of the environmental fungal contamination, the exploration of possible associations between related environmental variables and the study of the relationship between fungal contamination of air and surfaces. A descriptive study was developed based upon air and surfaces monitoring for fungal contamination in ten indoor gymnasiums with a swimming pool located in Lisbon’s urban area. Fifty 200 litres air samples and 120 surface swabs were collected. Surfaces samples were collected before and after cleaning and disinfection and temperature and relative humidity values were registered during the collection period. Twenty five different species of fungi were identified in the air samples, being the three most commonly isolated genera the following: Cladosporium (36.6%), Penicillium (19.0%) and Aspergillus (10.2%). Thirty-seven different species of fungi were identified in the surface samples. Fusarium sp. was the most frequent genera before (19.1%) and after (17.2%) cleaning and disinfection. There was a significant association between the numbers of visitors and the fungal contamination determined in the surface samples (p<0.05). There was no significant association (p>0.05) between the contamination encountered in the air samples and the one registered in the surface samples and between the fungal contamination and the temperature or relative humidity measured on location. The data obtained enabled the assessment of the establishment’s fungal contamination and led the authors to conclude, consequently, that physical activity, which generally promotes health, can in fact be challenged by this factor.
Resumo:
Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.
Resumo:
Introdução – Apesar de em Portugal se verificar o aumento da indústria da produção de aves para consumo humano, apenas alguns estudos incidem sobre a qualidade do ar interior e as implicações da sua degradação. Objectivos – Descrever a contaminação fúngica num aviário, analisar possíveis associações com a temperatura ambiente e a humidade relativa e o possível impacto na saúde dos consumidores e trabalhadores desta unidade. Métodos – Foi desenvolvido um estudo descritivo para avaliar a contaminação fúngica num aviário. Colheram‑se 5 amostras de ar de 100 litros através do método de compactação e 4 amostras de superfícies, utilizando a técnica da zaragatoa e um quadrado de 10 cm de lado de metal. Simultaneamente, os parâmetros ambientais – temperatura ambiente e humidade relativa – também foram medidos. Resultados – Foram identificadas vinte espécies de fungos no ar, sendo os seguintes os quatro géneros mais comummente isolados: Cladosporium (40,5%), Alternaria (10,8%), Chrysosporium e Aspergillus (6,8%). Nas superfícies, 21 espécies de fungos foram identificadas, sendo os 4 géneros mais identificados Penicillium (51,8%), Cladosporium (25,4%), Alternaria (6,1%) e Aspergillus (4,2%). Importa referir o facto de Aspergillus flavus, também isolado no ar, ser reconhecido como produtor de micotoxinas (aflatoxina) e Aspergillus fumigatus, uma das espécies isoladas no ar e superfícies, ser capaz de causar aspergilose grave ou fatal. Não se verificou relação significativa (p> 0,05) entre a contaminação fúngica e as variáveis ambientais. Conclusão – Caracterizou‑se a distribuição fúngica no ar e superfícies do aviário e analisou‑se a possível influência das variáveis ambientais. Foi reconhecido um potencial problema de Saúde Pública devido à contaminação fúngica e à possível produção de micotoxinas com a eventual contaminação dos produtos alimentares. A contaminação fúngica, particularmente causada pelo Aspergillus fumigatus, e a possível presença de micotoxinas no ar, devem ser encaradas também como fatores de risco neste contexto ocupacional. ABSTRACT - Background – Although there is an increasingly industry that produce whole chickens for domestic consumption in Portugal, only few investigations have reported on the indoor air of these plants and the consequences of their degradation. Objectives – Describe one poultry environmental fungal contamination analyse possible associations between temperature and relative humidity and its possible impact on the health of consumers and of the poultry workers. Methods – A descriptive study was developed to monitor one poultry fungal contamination. Five air samples of 100 litres through impaction method were collected and 4 swab samples from surfaces were also collected using a 10 cm square of metal. Simultaneously, environmental parameters – temperature and relative humidity – were also measured. Results – Twenty species of fungi in air were identified, being the 4 most commonly isolated the following genera: Cladosporium (40.5%), Alternaria (10.8%), Chrysosporium and Aspergillus (6.8%). In surfaces, 21 species of fungi were identified, being the 4 genera more identified Penicillium (51.8%), Cladosporium (25.4%), Alternaria (6.1%) and Aspergillus (4.2%). In addition, Aspergillus flavus also isolated in the poultry air is a well‑known producer of potent mycotoxins (aflatoxin), and Aspergillus fumigatus, one of the species isolated in air and surfaces, is capable of causing severe or fatal aspergillosis. There was no significant relationship (p>0,05) between fungal contamination and environmental variables. Conclusions – Was characterized fungal distribution in poultry air and surfaces and analyzed the association of environmental variables. It was recognized the Public Health problem because of fungal contamination and also due to probable mycotoxins production with the possible contamination of food products. Fungal contamination, particularly due to the presence of Aspergillus fumigatus and also the possible presence of mycotoxins in the air, should be seen as risk factor in this occupational setting.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.
Resumo:
Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.
Resumo:
Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.
Resumo:
As redes de telecomunicações nos últimos anos têm sofrido um grande desenvolvimento a nível tecnológico. A prova disso é a revolução das redes sem fios, iniciada com a tecnologia GSM (Global System Mobile) nos anos 90, na qual eram apenas disponibilizados serviços de voz. Esta tendência continuou com o GPRS (General Packet Radio Service) onde se iniciaram os serviços de dados surgindo assim mais tarde, a tecnologia UMTS (Universal Mobile Telecommunications System). Com o aparecimento da nova tecnologia LTE (Long-Term Evolution), surgiu um novo paradigma consumista no mercado, facto que gerou um conflicto directo com as redes de banda larga (ADSL - Asymmetric Digital Subscriber Line) fornecidas anteriormente apenas pela rede fixa. A partir deste momento, estas duas tecnologias passaram a oferecer altos débitos de dados, eliminando assim esta diferenciação existente até então entre ambas. Esta foi a plataforma que despoletou o meu interesse em explorar a tecnologia LTE, mais precisamente, o planeamento de rádio em ambientes Indoor e Outdoor. Este planeamento requeria uma comparação prática e teórica, de forma a observar que a tecnologia reflectia os valores estipulados na norma LTE. Como método de comparação foi utilizada uma ferramenta de planeamento de redes móveis, gentilmente disponibilizada pela Alcatel-Lucent para o tipo de ambiente outdoor em estudo, para o indoor não foi efectuado simulação, por indisponibilidade da ferramenta. Após a configuração do sistema de rádio foi efectuada a recolha de dados no terreno através de drive-testes. Findo esta fase, procedeu-se ao pós-processamento e análise dos dados recolhidos, por forma a ser possível estabelecer a comparação entre o planeamento teórico efectuado através da ferramenta de planeamento e os dados capturados no terreno. Os resultados obtidos demonstram que a cobertura preconizada no caso Outdoor estavam de acordo com o planeamento efectuado, uma vez que os dados medidos no terreno coincidiram com os valores simulados, apenas com um desvio mínimo dentro da margem de tolerância. No que respeita ao indoor verificou-se que as medidas estavam de acordo com o estipulado na norma. Como conclusão, confirmou-se a validade das ferramentas e da metodologia utilizada.
Resumo:
Mestrado em Segurança e Higiene no Trabalho.
Resumo:
Chromia (Cr2O3) has been extensively explored for the purpose of developing widespread industrial applications, owing to the convergence of a variety of mechanical, physical and chemical properties in one single oxide material. Various methods have been used for large area synthesis of Cr2O3 films. However, for selective area growth and growth on thermally sensitive materials, laser-assisted chemical vapour deposition (LCVD) can be applied advantageously. Here we report on the growth of single layers of pure Cr2O3 onto sapphire substrates at room temperature by low pressure photolytic LCVD, using UV laser radiation and Cr(CO)(6) as chromium precursor. The feasibility of the LCVD technique to access selective area deposition of chromia thin films is demonstrated. Best results were obtained for a laser fluence of 120 mJ cm(-2) and a partial pressure ratio of O-2 to Cr(CO)(6) of 1.0. Samples grown with these experimental parameters are polycrystalline and their microstructure is characterised by a high density of particles whose size follows a lognormal distribution. Deposition rates of 0.1 nm s(-1) and mean particle sizes of 1.85 mu m were measured for these films. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The deposition of highly oriented a-axis CrO(2) films onto Al(2)O(3)(0001) by atmospheric pressure (AP)CVD at temperatures as low as 330 C is reported. Deposition rates strongly depend on the substrate temperature, whereas for film surface microstructures the dependence is mainly on film thickness. For the experimental conditions used in this work, CrO(2) growth kinetics are dominated by a surface reaction mechanism with an apparent activation energy of (121.0 +/- 4.3) kJ mol(-1). The magnitude and temperature dependence of the saturation magnetization, up to room temperature, is consistent with bulk measurements.
Resumo:
In this work we report on the structure and magnetic and electrical transport properties of CrO2 films deposited onto (0001) sapphire by atmospheric pressure (AP)CVD from a CrO3 precursor. Films are grown within a broad range of deposition temperatures, from 320 to 410 degrees C, and oxygen carrier gas flow rates of 50-500 seem, showing that it is viable to grow highly oriented a-axis CrO2 films at temperatures as low as 330 degrees C i.e., 60-70 degrees C lower than is reported in published data for the same chemical system. Depending on the experimental conditions, growth kinetic regimes dominated either by surface reaction or by mass-transport mechanisms are identified. The growth of a Cr2O3 interfacial layer as an intrinsic feature of the deposition process is studied and discussed. Films synthesized at 330 degrees C keep the same high quality magnetic and transport properties as those deposited at higher temperatures.