19 resultados para in-field detection
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Two fluorescent molecular receptor based conjugated polymers were used in the detection of a nitroaliphatic liquid explosive (nitromethane) and an explosive taggant (2,3-dimethyl-2,3-dinitrobutane) in the vapor phase. Results have shown that thin films of both polymers display remarkably high sensitivity and selectivity toward these analytes. Very fast, reproducible, and reversible responses were found. The unique behavior of these supramolecular host systems is ascribed to cooperativity effects developed between the calix[4] arene hosts and the phenylene ethynylene-carbazolylene main chains. The calix[4]-arene hosts create a plethora of host-guest binding sites along the polymer backbone, either in their bowl-shaped cavities or between the outer walls of the cavity, to direct guests to the area of the transduction centers (main chain) at which favorable photoinduced electron transfer to the guest molecules occurs and leads to the observed fluorescence quenching. The high tridimensional porous nature of the polymers imparted by the bis-calixarene moieties concomitantly allows fast diffusion of guest molecules into the polymer thin films.
Resumo:
We propose a blind method to detect interference in GNSS signals whereby the algorithms do not require knowledge of the interference or channel noise features. A sample covariance matrix is constructed from the received signal and its eigenvalues are computed. The generalized likelihood ratio test (GLRT) and the condition number test (CNT) are developed and compared in the detection of sinusoidal and chirp jamming signals. A computationally-efficient decision threshold was proposed for the CNT.
Resumo:
The main properties of strangelets, namely their energy per baryon, radius and electric charge, are studied in the unpaired magnetized strange quark matter (MSQM) and paired magnetized colour flavour locked (MCFL) phases. Temperature effects are taken into account in order to study their stability compared to the Fe-56 isotope and nonmagnetized strangelets within the framework of the MIT bag model. We conclude that the presence of a magnetic field tends to stabilize the strangelets more, even when temperature is considered. It is also shown that MCFL strangelets are more stable than ordinary MSQM strangelets for typical gap values of the order of O(100) MeV. A distinctive feature in the detection of strangelets either in cosmic rays or in heavy-ion collider experiments could be their electric charge. We find that the electric charge is modified in the presence of the magnetic field, leading to higher (lower) charge values for MSQM (MCFL) strangelets, when compared to the nonmagnetized case.
Resumo:
Purpose - The study evaluates the pre- and post-training lesion localisation ability of a group of novice observers. Parallels are drawn with the performance of inexperienced radiographers taking part in preliminary clinical evaluation (PCE) and ‘red-dot’ systems, operating within radiography practice. Materials and methods - Thirty-four novice observers searched 92 images for simulated lesions. Pre-training and post-training evaluations were completed following the free-response the receiver operating characteristic (FROC) method. Training consisted of observer performance methodology, the characteristics of the simulated lesions and information on lesion frequency. Jackknife alternative FROC (JAFROC) and highest rating inferred ROC analyses were performed to evaluate performance difference on lesion-based and case-based decisions. The significance level of the test was set at 0.05 to control the probability of Type I error. Results - JAFROC analysis (F(3,33) = 26.34, p < 0.0001) and highest-rating inferred ROC analysis (F(3,33) = 10.65, p = 0.0026) revealed a statistically significant difference in lesion detection performance. The JAFROC figure-of-merit was 0.563 (95% CI 0.512,0.614) pre-training and 0.677 (95% CI 0.639,0.715) post-training. Highest rating inferred ROC figure-of-merit was 0.728 (95% CI 0.701,0.755) pre-training and 0.772 (95% CI 0.750,0.793) post-training. Conclusions - This study has demonstrated that novice observer performance can improve significantly. This study design may have relevance in the assessment of inexperienced radiographers taking part in PCE or commenting scheme for trauma.
Resumo:
Purpose - In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Materials and methods - Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (−1.00 D and −2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1–4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. Results - All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to −1.00 D and for one observer when defocussed to −2.00 D. Stereoacuity was unacceptable for one observer when defocussed to −2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). Conclusion - A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function.
Resumo:
Background - Image blurring in Full Field Digital Mammography (FFDM) is reported to be a problem within many UK breast screening units resulting in significant proportion of technical repeats/recalls. Our study investigates monitors of differing pixel resolution, and whether there is a difference in blurring detection between a 2.3 MP technical review monitor and a 5MP standard reporting monitor. Methods - Simulation software was created to induce different magnitudes of blur on 20 artifact free FFDM screening images. 120 blurred and non-blurred images were randomized and displayed on the 2.3 and 5MP monitors; they were reviewed by 28 trained observers. Monitors were calibrated to the DICOM Grayscale Standard Display Function. T-test was used to determine whether significant differences exist in blurring detection between the monitors. Results - The blurring detection rate on the 2.3MP monitor for 0.2, 0.4, 0.6, 0.8 and 1 mm blur was 46, 59, 66, 77and 78% respectively; and on the 5MP monitor 44, 70, 83 , 96 and 98%. All the non-motion images were identified correctly. A statistical difference (p <0.01) in the blurring detection rate between the two monitors was demonstrated. Conclusions - Given the results of this study and knowing that monitors as low as 1 MP are used in clinical practice, we speculate that technical recall/repeat rates because of blurring could be reduced if higher resolution monitors are used for technical review at the time of imaging. Further work is needed to determine monitor minimum specification for visual blurring detection.
Resumo:
Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.
Resumo:
Introdução – A dosimetria in vivo é útil na medição da dose administrada aos doentes durante o tratamento, avaliando diferenças significativas entre a dose prescrita e a dose administrada no volume alvo, bem como nos órgãos de risco. Objetivo – Comparar a dose medida com a dose calculada em doentes com tumores de mama com e sem filtro físico. Métodos – Realizaram-se medições da dose na pele, utilizando díodos tipo–p, para os campos tangenciais e respetivos field-in-field em 38 doentes. Resultados – Verificaram-se diferenças estatisticamente significativas nos campos tangenciais open (ρ=0,000). Discussão – Estudos reportam desvios sistemáticos significativos entre a dose calculada e a dose medida. Conclusão – Com este estudo conclui-se que não existe influência nas doses devido à presença do filtro físico.
Resumo:
Objetivo – Comparar a técnica convencional, a técnica de energias mistas e a técnica field-in-field com energias mistas, verificando a dose recebida nos órgãos de risco e no volume alvo. Metodologia – Quinze doentes com carcinoma da mama esquerda classificadas de T1-T3N0M0 foram tratadas com cirurgia conservadora da mama, seguida de radioterapia pós-operatória. Para cada doente realizaram-se 3 planeamentos dosimétricos, sendo que cada um deles diz respeito a uma das diferentes técnicas em estudo. Através dos HDV gerados avaliaram-se a Dmáx, Dmed, Dmín, D95%, D3% e a homogeneidade da dose no volume alvo, bem como a dose nos órgãos de risco. Utilizou-se o teste de Friedman para verificar a significância do estudo, com um intervalo de confiança de 95%. Resultados – Relativamente ao pulmão esquerdo e ao coração obtiveram-se, com a técnica field-in-field com energias mistas, doses inferiores em comparação com as outras duas técnicas. Para a Dmáx e a homogeneidade de dose no PTV, a técnica field-in-field com energias mistas revelou-se mais eficaz, comparativamente às outras técnicas. No entanto, verificou-se uma melhor cobertura de dose no PTV com a técnica convencional. Considerações finais – A técnica field-in-field com energias mistas permite uma redução da dose nos órgãos de risco, uma redução significativa da Dmáx no PTV e melhora a homogeneidade da dose, comparativamente com as outras técnicas. Os resultados obtidos com a técnica field-in-field com energias mistas apontam para a redução dos efeitos secundários provocados pelo tratamento. ABSTRACT - Purpose – To compare the conventional technique, the technique of mixed energies and the technique field-in-field with mixed energies, checking the received dose in organs at risk and target volume. Methods – Fifteen patients with carcinoma of the left breast classified as T1-T3N0M0 were treated with breast-conserving surgery, followed by postoperative radiotherapy. For each patient were carried out three dosimetric plannings, each one of them concerns the different techniques under study. Through the DVH generated to evaluate Dmax, Dmed, Dmin, D95%, D3% and the homogeneity of the target volume dose, well as the dose in organs at risk. We used the Friedman test to assess the significance of the study, with a confidence interval of 95%. Results – For the left lung and heart were obtained with the technique field-in-field with mixed energies, lower doses compared with the other two techniques. For the Dmax and the homogeneity of the PTV dose, the technique field-in-field with mixed energies was more effective compared to other techniques. However, there was a better coverage of the PTV dose with conventional technique. Conclusions – The technique field-in-field with mixed energy allows a reduction in dose for organs at risk, a significant reduction Dmax in PTV and improves the homogeneity of the dose compared with other techniques. The results obtained with the technique field-in-field with mixed energy indicate to reduce the side effects caused by the treatment.
Resumo:
Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.
Resumo:
Neonatal anthropometry is an inexpensive, noninvasive and convenient tool for bedside evaluation, especially in sick and fragile neonates. Anthropometry can be used in neonates as a tool for several purposes: diagnosis of foetal malnutrition and prediction of early postnatal complications; postnatal assessment of growth, body composition and nutritional status; prediction of long-term complications including metabolic syndrome; assessment of dysmorphology; and estimation of body surface. However, in this age group anthropometry has been notorious for its inaccuracy and the main concern is to make validated indices available. Direct measurements, such as body weight, length and body circumferences are the most commonly used measurements for nutritional assessment in clinical practice and in field studies. Body weight is the most reliable anthropometric measurement and therefore is often used alone in the assessment of the nutritional status, despite not reflecting body composition. Derived indices from direct measurements have been proposed to improve the accuracy of anthropometry. Equations based on body weight and length, mid-arm circumference/head circumference ratio, and upper-arm cross-sectional areas are among the most used derived indices to assess nutritional status and body proportionality, even though these indices require further validation for the estimation of body composition in neonates.
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias da Saúde