24 resultados para delay-line position sensitive detector

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Helicobacter pylori infection represents a serious health problem, given its association with serious gastric diseases as gastric ulcers, cancer and MALT lymphoma. Currently no vaccine exists and antibiotic-based eradication therapy is already failing in more than 20% of cases. To increase the knowledge on the infection process diverse gastric cell lines, e.g. the adenocarcinona gastric (AGS) cell line, are routinely used has in vitro models of gastric epithelia. In the present work the molecular fingerprint of infected and non-infected AGS cell lines, by diverse H. pylori strains, was acquired using vibrational infrared spectroscopy. These molecular fingerprints enabled to discriminate infected from non-infected AGS cells, and infection due to different strains, by performing Principal Component Analysis. It was also possible to estimate, from the AGS cells molecular fingerprint, the effect of the infection on diverse biochemical and metabolic cellular status. In resume infra-red spectroscopy enabled the acquisition of infected AGS cells molecular fingerprint with minimal sample preparation, in a rapid, high-throughput, economic process yielding highly sensitive and informative data, most useful for promoting critical knowledge on the H. pylori infection process. © 2015 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este relatório, escrito no âmbito do estágio profissional realizado no departamento de Manutenção e Engenharia da TAP Portugal, com o tema “Análise do Line Maintenance Manual numa perspectiva de melhoria contínua do Programa de Manutenção Avião”, tem como objectivo descrever a análise efectuada e as oportunidades de melhoria identificadas no Line Maintenance Manual, documento que serve de suporte às actividades da Manutenção de Linha. Espera-se que o trabalho realizado traga benefícios para a TAP Manutenção e Engenharia a médio e longo prazo, tais como a agilização das futuras revisões ao referido documento, a redução de recursos envolvidos nas inspecções de trânsito e, quiçá, a correcção de aspectos com implicações directas na operação segura das aeronaves. O trabalho desenvolvido no estágio implicou um estudo aprofundado do processo que resulta no estabelecimento dos programas de manutenção das aeronaves actuais, bem como dos documentos nele envolvidos, pelo que a análise específica do Line Maintenance Manual foi realizada no contexto muito mais abrangente da teoria da Manutenção Aeronáutica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new circuit topology is proposed to replace the actual pulse transformer and thyratron based resonant modulator that supplies the 60 kV target potential for the ion acceleration of the On-Line Isotope Mass Separator accelerator, the stability of which is critical for the mass resolution downstream separator, at the European Organization for Nuclear Research. The improved modulator uses two solid-state switches working together, each one based on the Marx generator concept, operating as series and parallel switches, reducing the stress on the series stacked semiconductors, and also as auxiliary pulse generator in order to fulfill the target requirements. Preliminary results of a 10 kV prototype, using 1200 V insulated gate bipolar transistors and capacitors in the solid-state Marx circuits, ten stages each, with an electrical equivalent circuit of the target, are presented, demonstrating both the improved voltage stability and pulse flexibility potential wanted for this new modulator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We start by studying the existence of positive solutions for the differential equation u '' = a(x)u - g(u), with u ''(0) = u(+infinity) = 0, where a is a positive function, and g is a power or a bounded function. In other words, we are concerned with even positive homoclinics of the differential equation. The main motivation is to check that some well-known results concerning the existence of homoclinics for the autonomous case (where a is constant) are also true for the non-autonomous equation. This also motivates us to study the analogous fourth-order boundary value problem {u((4)) - cu '' + a(x)u = vertical bar u vertical bar(p-1)u u'(0) = u'''(0) = 0, u(+infinity) = u'(+infinity) = 0 for which we also find nontrivial (and, in some instances, positive) solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large area colour imager optically addressed is presented. The colour imager consists of a thin wide band gap p-i-n a-SiC:H filtering element deposited on the top of a thick large area a-SiC:H(-p)/a-Si:H(-i)/a-SiC:H(-n) image sensor, which reveals itself an intrinsic colour filter. In order to tune the external applied voltage for full colour discrimination the photocurrent generated by a modulated red light is measured under different optical and electrical bias. Results reveal that the integrated device behaves itself as an imager and a filter giving information not only on the position where the optical image is absorbed but also on it wavelength and intensity. The amplitude and sign of the image signals are electrically tuneable. In a wide range of incident fluxes and under reverse bias, the red and blue image signals are opposite in sign and the green signal is suppressed allowing blue and red colour recognition. The green information is obtained under forward bias, where the blue signal goes down to zero and the red and green remain constant. Combining the information obtained at this two applied voltages a RGB colour image picture can be acquired without the need of the usual colour filters or pixel architecture. A numerical simulation supports the colour filter analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo tem como principal objetivo identificar na interação mãe- bebés de 3 meses, indicadores de risco e de qualidade e, consequentemente, criar um guião que ajude os profissionais a identificar esses mesmos indicadores. Para o efeito observámos 30 díades mãe-filho(a) em jogo livre distribuídas em dois grupos: 1) 12 díades sem condições assinaláveis de risco e 2) 18 díades em risco socioeconómico. O comportamento interativo dos bebés e das mães foi avaliado através do Child-Adult Relashionship Experimental, designado pela autora de CARE-Index (Crittenden, 2003). Os comportamentos maternos e infantis foram cotados de acordo com os 7 aspetos do comportamento diádico: Expressão Facial, Expressão Verbal, Posição e Contato Corporal, Afetividade, Reciprocidade, Diretividade e Escolha da Atividade. Os resultados do nosso estudo revelam que as díades mãe-filho(a) sem condições assinaláveis de risco apresentam interações mais positivas, recíprocas e ajustadas à idade das crianças do que as díades sujeitas a condições de risco e que o comportamento materno sensível e responsivo surge associado ao comportamento cooperativo infantil e negativamente correlacionado com a dificuldade infantil, enquanto que uma postura controladora, diretiva ou punitiva da mãe surge positivamente correlacionada com a submissão e evitamento infantil. Por fim, encontramos associados a comportamentos maternos sensíveis uma variabilidade de comportamentos infantis desde satisfação, coerção, procura de proximidade ou evitamento. Na discussão dos resultados apresentamos um script dos indicadores de qualidade e de risco do comportamento materno. - Abstract This study main goal was to study mother-infant quality of interaction in dyads with 3 months babies. Moreover, our goal was to explore maternal and infant key behaviors that shape the quality of the interaction in order to organize a script that helps professionals to identify these critical interactive behaviors. To this end we observed 30 mother-child dyads (a) in free play interaction divided into two groups: 1) 12 dyads without any known risk condition and 2) 18 dyads at socioeconomic risk. The interactive behavior of infants and mothers was assessed using the Child-Adult Relationship Experimental, designated by the author of CARE-Index (Crittenden, 2003). The maternal and infant behaviors were rated according to seven aspects of dyadic behavior: Facial Expression, Verbal Expression, Position and Contact Body, Affection, Reciprocity, Directivity and Choice of Activity. Findings indicate that mother-child dyads without know risk conditions are more likely to present positive interactions, reciprocal and age-adjusted than dyads at risk. The sensitive and responsive maternal behavior emerges associated with children's cooperative behavior and negatively correlated with infant difficultness, while a controlling or punitive maternal behavior is positively correlated with infant compliance and avoidance. Finally, sensitive maternal behaviors were associated with a variability of child behaviors, from satisfaction, coercion, avoidance or proximity search. In the results discussion we present a script of the quality and risks indicators of maternal behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Proteção contra Radiações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an implementation of a long distance echo canceller, operating on full-duplex with hands-free and in real-time with a single Digital Signal Processor (DSP). The proposed solution is based on short length adaptive filters centered on the positions of the most significant echoes, which are tracked by time delay estimators, for which we use a new approach. To deal with double talking situations a speech detector is employed. The floating-point DSP TMS320C6713 from Texas Instruments is used with software written in C++, with compiler optimizations for fast execution. The resulting algorithm enables long distance echo cancellation with low computational requirements, suited for embbeded systems. It reaches greater echo return loss enhancement and shows faster convergence speed when compared to the conventional approach. The experimental results approach the CCITT G.165 recommendation levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CDC25 phosphatases control cell cycle progression by activating cyclin dependent kinases. The three CDC25 isoforms encoding genes are submitted to alternative splicing events which generate at least two variants for CDC25A and five for both CDC25B and CDC25C. An over-expression of CDC25 was reported in several types of cancer, including breast cancer, and is often associated with a poor prognosis. Nevertheless, most of the previous studies did not address the expression of CDC25 splice variants. Here, we evaluated CDC25 spliced transcripts expression in anti-cancerous drug-sensitive and resistant breast cancer cell lines in order to identify potential breast cancer biomarkers. Methods: CDC25 splice variants mRNA levels were evaluated by semi-quantitative RT-PCR and by an original real-time RT-PCR assay. Results: CDC25 spliced transcripts are differentially expres-sed in the breast cancer cell lines studied. An up-regulation of CDC25A2 variant and an increase of the CDC25C5/C1 ratio are associated to the multidrug-resistance in VCREMS and DOXOR breast cancer cells, compared to their sensitive counterpart cell line MCF-7. Additionally, CDC25B2 tran-script is exclusively over-expressed in VCREMS resistant cells and could therefore be involved in the development of certain type of drug resistance. Conclusions: CDC25 splice variants could represent interesting potential breast cancer prognostic biomarkers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine self-consistently the time evolution of particle size and their number density in situ multi-angle polarization-sensitive laser light scattering was used. Cross-polarization intensities (incident and scattered light intensities with opposite polarization) measured at 135 degrees and ex situ transmission electronic microscopy analysis demonstrate the existence of nonspherical agglomerates during the early phase of agglomeration. Later in the particle time development both techniques reveal spherical particles again. The presence of strong cross-polarization intensities is accompanied by low-frequency instabilities detected on the scattered light intensities and plasma emission. It is found that the particle radius and particle number density during the agglomeration phase can be well described by the Brownian free molecule coagulation model. Application of this neutral particle coagulation model is justified by calculation of the particle charge whereby it is shown that particles of a few tens of nanometer can be considered as neutral under our experimental conditions. The measured particle dispersion can be well described by a Brownian free molecule coagulation model including a log-normal particle size distribution. (C) 1996 American Institute of Physics.