17 resultados para Visual perception tests
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.
Resumo:
The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.
Resumo:
Aims of study: 1) Describe the importance of human visual system on lesion detection in medical imaging perception research; 2) Discuss the relevance of research in medical imaging addressing visual function analysis; 3) Identify visual function tests which could be conducted on observers prior to participation in medical imaging perception research.
Resumo:
Introdução – Na avaliação diagnóstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnóstico. Objetivo – Descrever a importância da perceção visual na análise da mamografia, identificando os principais fatores que contribuem para a perceção visual do radiologista e que condicionam a acuidade diagnóstica. Metodologia – Estudo descritivo baseado numa revisão sistemática de literatura através da PubMed e da Science Direct. Foram incluídos 42 artigos que respeitavam, pelo menos, um dos critérios de inclusão no estudo. Para a seleção das referências foi utilizada a metodologia PRISMA, constituída por 4 fases: identificação, seleção preliminar, elegibilidade e estudos incluídos. Resultados – Na avaliação diagnóstica em mamografia, a perceção visual está intimamente relacionada com: 1) diferentes parâmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e à luminância e movimentos oculares); 2) com condições de visualização de uma imagem (iluminância da sala e luminância do monitor); e 3) fadiga ocular provocada pela observação diária consecutiva de imagens. Conclusões – A perceção visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (lesões não são fixadas pela fóvea), erros de reconhecimento (lesões fixadas, mas não durante o tempo suficiente) e erros de decisão (lesões fixadas, mas não identificadas como suspeitas). Os estudos analisados sobre perceção visual, atenção visual e estratégia visual, bem como os estudos sobre condições de visualização não caracterizam a função visual dos observadores. Para uma avaliação correta da perceção visual em mamografia deverão ser efetuados estudos que correlacionem a função visual com a qualidade diagnóstica. ABSTRACT - Introduction – Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims – To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods – In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results – Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions – Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observer’s visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Audiovisual e Multimédia.
Resumo:
Trabalho de projeto apresentado à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Audiovisual e Multimédia.
Resumo:
Relatório de Estágio Curricular para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes
Resumo:
Screening programs, particularly the inclusion of specific orthoptic tests to detect visual abnormalities, varies among countries. This study aims to: 1) describes expert perception of issues related with children visual screening; 2) identify specific orthoptic tests to detect visual abnormalities in children visual screening.
Expert opinion on best practice guidelines and competency framework for visual screening in children
Resumo:
PURPOSE: Screening programs to detect visual abnormalities in children vary among countries. The aim of this study is to describe experts' perception of best practice guidelines and competency framework for visual screening in children. METHODS: A qualitative focus group technique was applied during the Portuguese national orthoptic congress to obtain the perception of an expert panel of 5 orthoptists and 2 ophthalmologists with experience in visual screening for children (mean age 53.43 years, SD ± 9.40). The panel received in advance a script with the description of three tuning competencies dimensions (instrumental, systemic, and interpersonal) for visual screening. The session was recorded in video and audio. Qualitative data were analyzed using a categorical technique. RESULTS: According to experts' views, six tests (35.29%) have to be included in a visual screening: distance visual acuity test, cover test, bi-prism or 4/6(Δ) prism, fusion, ocular movements, and refraction. Screening should be performed according to the child age before and after 3 years of age (17.65%). The expert panel highlighted the influence of the professional experience in the application of a screening protocol (23.53%). They also showed concern about the false negatives control (23.53%). Instrumental competencies were the most cited (54.09%), followed by interpersonal (29.51%) and systemic (16.4%). CONCLUSIONS: Orthoptists should have professional experience before starting to apply a screening protocol. False negative results are a concern that has to be more thoroughly investigated. The proposed framework focuses on core competencies highlighted by the expert panel. Competencies programs could be important do develop better screening programs.
Resumo:
Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.
Resumo:
The identification of core competencies which are important for undertaking accurate visual screening by orthoptists is considered in this study. The aim was to construct and validate a questionnaire for orthoptists to assess visual screening competency. This study comprised three steps. The first step involved a 69-item self-assessment questionnaire constructed to assess orthoptists' perception of their competencies in visual screening programs for children. This questionnaire was constructed with statements from the Orthoptic Benchmark Statement for Health Care Programmes (Quality Assurance Agency for Higher Education, UK) and included three competency dimensions: interpersonal (IP), instrumental (IT) and systemic (ST). The second step involved questionnaire translation.
Resumo:
Relevant past events can be remembered when visualizing related pictures. The main difficulty is how to find these photos in a large personal collection. Query definition and image annotation are key issues to overcome this problem. The former is relevant due to the diversity of the clues provided by our memory when recovering a past moment and the later because images need to be annotated with information regarding those clues to be retrieved. Consequently, tools to recover past memories should deal carefully with these two tasks. This paper describes a user interface designed to explore pictures from personal memories. Users can query the media collection in several ways and for this reason an iconic visual language to define queries is proposed. Automatic and semi-automatic annotation is also performed using the image content and the audio information obtained when users show their images to others. The paper also presents the user interface evaluation based on tests with 58 participants.
Resumo:
The aim of this study was to describe experts’ perception of best-practice guidelines and competency framework for visual screening in children. This study uses qualitative data and shows individual/ group conceptualization. The use of evidence from qualitative studies has traditionally been a fundamental source of knowledge in the clinical and social sciences.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.
Resumo:
Purpose: It is important to establish a differential diagnosis between the different types of nystagmus, in order to give the appropriate clinical approach to every situation and to improve visual acuity. The nystagmus is normally blocked when the eyes are positioned in a particular way. This makes the child adopt a posture of ocular torticollis that reduces the nistagmiformes movements, improving the vision in this position. A way to promote the blocking of the nystagmic movements is by using prismatic lenses with opposite bases, to block or minimize the oscillatory movements. This results in a vision improvement and it reduces the anomalous head position. There is limited research on the visual results in children with nystagmus after using prisms with opposing bases. Our aim is to describe the impact on the visual acuity (VA ) of theprescription prism lenses in a nystagmus patient starting at 3 months of age. Methods: Case report on thirty month old caucasian male infant, with normal growth and development for their age, with an early onset of horizontal nystagmus at 3 months of age. Ophthalmic examination included slit lamp examination, fundus, refractive study, electrophysiological and magnetic resonance tests, measurement of VA over time with the Teller Acuity Cards (TAC ) in the distance agreed for the age. At age ten months, the mother noted a persistent turn to the right of the child’s head, which became increasingly more severe along the months. There’s no oscillopcia. At 24 months, an atropine refraction showed the following refractive error: 0D.: -1,50, OS: -0,50 and prismatic lens adapting OD 8 Δ nasal base and OE 8 Δ temporal base. Results: Thirty month old child, with adequate development for their age, with onset of idiopatic horizontal nystagmus, at 3 months of age. Normal ocular fundus and magnetic ressoance without alterations, sub-normal results in electrophysiological tests and VA with values below normal for age. At 6 months OD 20/300; OE 20/400; OU 20/300. At 9 months OD 20/250; OE 20/300; OU 20/150 (TAC a 38 cm). At 18 months OD 20/200; OE 20/100; OU 20/80 (TAC at 38 cm), when the head is turned to the right and the eyes in levoversão, the nystagmus decreases in a “neutral” area. At 24 month, with the prismatic glasses, OD 20/200 OE 20/100, OU20/80 (TAC at 54 cm, reference value is 20/30 – 20/100 para OU e 20/40 – 20/100 monocular), there was an increase in the visual acuity. The child did visual stimulation with multimedia devices and using glasses. After adaptation of prisms: at 30 months VA (with Cambridge cards) OD e OE = 6/18. The child improved the VA and reduced the anomalous head position. There is also improvement in mobility and fine motricity. Conclusion: Prisms with opposing bases., were used in the treatment of idiopathic nystagmus. Said prisms were adapted to reduce the skewed position of the head, and to improve VA and binocular function. Monitoring of visual acuity and visual stimulation was done using electronic devices. Following the use of prismatic, the patient improved significantly VA and the anomalous head position was reduced.