13 resultados para Pressure ratio

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Chromia (Cr2O3) has been extensively explored for the purpose of developing widespread industrial applications, owing to the convergence of a variety of mechanical, physical and chemical properties in one single oxide material. Various methods have been used for large area synthesis of Cr2O3 films. However, for selective area growth and growth on thermally sensitive materials, laser-assisted chemical vapour deposition (LCVD) can be applied advantageously. Here we report on the growth of single layers of pure Cr2O3 onto sapphire substrates at room temperature by low pressure photolytic LCVD, using UV laser radiation and Cr(CO)(6) as chromium precursor. The feasibility of the LCVD technique to access selective area deposition of chromia thin films is demonstrated. Best results were obtained for a laser fluence of 120 mJ cm(-2) and a partial pressure ratio of O-2 to Cr(CO)(6) of 1.0. Samples grown with these experimental parameters are polycrystalline and their microstructure is characterised by a high density of particles whose size follows a lognormal distribution. Deposition rates of 0.1 nm s(-1) and mean particle sizes of 1.85 mu m were measured for these films. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work reports on the synthesis of chromium (III, IV) oxides films by KrF laser-assisted CVD. Films were deposited onto sapphire substrates at room temperature by the photodissociation of Cr(CO)(6) in dynamic atmospheres containing oxygen and argon. A study of the processing parameters has shown that partial pressure ratio Of O-2 to Cr(CO)(6) and laser fluence are the prominent parameters that have to be accurately controlled in order to co-deposit both the crystalline oxide phases. Films consistent with such a two-phase system were synthesised for a laser fluence of 75 mJ cm(-2) and a partial pressure ratio of about 1. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho estudou-se a lixiviação em meio sulfúrico do zinco e outros metais de valor de um concentrado zinco, tendo-se realizado ensaios de lixiviação à pressão atmosférica e em autoclave. Nos estudos de lixiviação utilizou-se o ião férrico (sulfato férrico) como agente oxidante e avaliaram-se os efeitos de diversas variáveis como a razão sólido/líquido, concentração do ião Fe (III), temperatura, a pressão de oxigénio e a presença de enxofre elementar na eficiência da lixiviação. Os ensaios de lixiviação em autoclave sob pressão de oxigénio foram realizados para verificar o efeito da manutenção da quantidade de Fe (III) na lixívia, por oxidação do Fe(II) com oxigénio. Os resultados obtidos mostraram que à pressão atmosférica para uma razão sólido/líquido de 5% foi possível lixiviar no máximo 59% de zinco e 22% de cobre com solução de 0,25 M de Fe2(SO4)3 e 0,50 M de H2SO4 em 2 horas a 60ºC e com uma razão sólido/líquido de 5% foi possível lixiviar no máximo 65% de zinco e 23% de cobre com uma solução de 0,5 M de Fe2(SO4)3 e 0,25 M de H2SO4 em 2 horas a 80ºC. Efectuar a lixiviação do concentrado de zinco sobre pressão de oxigénio permitiu aumentar a cinética da reacção de lixiviação, tendo sido possível lixiviar 97% de zinco e 48% do cobre em 2 horas de lixiviação com uma solução de 0,25 M Fe2(SO4)3 e 0,5 M H2SO4 a 95 ºC e a 6 bar de pressão de oxigénio (à entrada do reactor) com uma razão sólido/líquido de 5%. Utilizando razão sólido/líquido de 10 % foi possível lixiviar 93% de zinco e 54% do cobre com uma solução de 0,50 M Fe2(SO4)3 e 1,25 M H2SO4 a 95 ºC e a 6 bar de pressão de oxigénio, e para uma razão sólido/líquido de 20 % foi possível lixiviar 84% de zinco e 39% do cobre com uma solução de 0,11 M Fe2(SO4)3 e 2,00 M H2SO4 a 95 ºC e a 10 bar de pressão. As análises de difracção de Raios X efectuados aos resíduos de lixiviação revelaram que o enxofre era maioritariamente oxidado a enxofre elementar. Assim, para um dos ensaios de lixiviação em autoclave, verificou-se que a remoção com tetracloreto de carbono do enxofre elementar formado num primeiro andar de lixiviação (s/l=20%, 0,11 M Fe2(SO4)3 e 2,00 M H2SO4 a 95 ºC e a 10 bar de pressão) permitia aumentar a percentagem de zinco no segundo andar de 42 para 68%. Por último, o estudo do efeito da temperatura permitiu calcular como base nas velocidades iniciais do zinco a energia de activação para a lixiviação do zinco que foi de 39 ± 1.40 kJ/mol para a lixiviação em autoclave e de 38 ± 1.40 kJ/mol para a lixiviação à pressão atmosférica, o que é indicativo do controlo reaccional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have performed Surface Evolver simulations of two-dimensional hexagonal bubble clusters consisting of a central bubble of area lambda surrounded by s shells or layers of bubbles of unit area. Clusters of up to twenty layers have been simulated, with lambda varying between 0.01 and 100. In monodisperse clusters (i.e., for lambda = 1) [M.A. Fortes, F Morgan, M. Fatima Vaz, Philos. Mag. Lett. 87 (2007) 561] both the average pressure of the entire Cluster and the pressure in the central bubble are decreasing functions of s and approach 0.9306 for very large s, which is the pressure in a bubble of an infinite monodisperse honeycomb foam. Here we address the effect of changing the central bubble area lambda. For small lambda the pressure in the central bubble and the average pressure were both found to decrease with s, as in monodisperse clusters. However, for large,, the pressure in the central bubble and the average pressure increase with s. The average pressure of large clusters was found to be independent of lambda and to approach 0.9306 asymptotically. We have also determined the cluster surface energies given by the equation of equilibrium for the total energy in terms of the area and the pressure in each bubble. When the pressures in the bubbles are not available, an approximate equation derived by Vaz et al. [M. Fatima Vaz, M.A. Fortes, F. Graner, Philos. Mag. Lett. 82 (2002) 575] was shown to provide good estimations for the cluster energy provided the bubble area distribution is narrow. This approach does not take cluster topology into account. Using this approximate equation, we find a good correlation between Surface Evolver Simulations and the estimated Values of energies and pressures. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the crust, upper mantle and mantle transition zone of the Cape Verde hotspot by using seismic P and S receiver functions from several tens of local seismograph stations. We find a strong discontinuity at a depth of similar to 10 km underlain by a similar to 15-km thick layer with a high (similar to 1.9) Vp/Vs velocity ratio. We interpret this discontinuity and the underlying layer as the fossil Moho, inherited from the pre-hotspot era, and the plume-related magmatic underplate. Our uppermost-mantle models are very different from those previously obtained for this region: our S velocity is much lower and there are no indications of low densities. Contrary to previously published arguments for the standard transition zone thickness our data indicate that this thickness under the Cape Verde islands is up to similar to 30 km less than in the ambient mantle. This reduction is a combined effect of a depression of the 410-km discontinuity and an uplift of the 660-km discontinuity. The uplift is in contrast to laboratory data and some seismic data on a negligible dependence of depth of the 660-km discontinuity on temperature in hotspots. A large negative pressure-temperature slope which is suggested by our data implies that the 660-km discontinuity may resist passage of the plume. Our data reveal beneath the islands a reduction of S velocity of a few percent between 470-km and 510-km depths. The low velocity layer in the upper transition zone under the Cape Verde archipelago is very similar to that previously found under the Azores and a few other hotspots. In the literature there are reports on a regional 520-km discontinuity, the impedance of which is too large to be explained by the known phase transitions. Our observations suggest that the 520-km discontinuity may present the base of the low-velocity layer in the transition zone. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study explores a large set of OC and EC measurements in PM(10) and PM(2.5) aerosol samples, undertaken with a long term constant analytical methodology, to evaluate the capability of the OC/EC minimum ratio to represent the ratio between the OC and EC aerosol components resulting from fossil fuel combustion (OC(ff)/EC(ff)). The data set covers a wide geographical area in Europe, but with a particular focus upon Portugal, Spain and the United Kingdom, and includes a great variety of sites: urban (background, kerbside and tunnel), industrial, rural and remote. The highest minimum ratios were found in samples from remote and rural sites. Urban background sites have shown spatially and temporally consistent minimum ratios, of around 1.0 for PM(10) and 0.7 for PM(2.5).The consistency of results has suggested that the method could be used as a tool to derive the ratio between OC and EC from fossil fuel combustion and consequently to differentiate OC from primary and secondary sources. To explore this capability, OC and EC measurements were performed in a busy roadway tunnel in central Lisbon. The OC/EC ratio, which reflected the composition of vehicle combustion emissions, was in the range of 03-0.4. Ratios of OC/EC in roadside increment air (roadside minus urban background) in Birmingham, UK also lie within the range 03-0.4. Additional measurements were performed under heavy traffic conditions at two double kerbside sites located in the centre of Lisbon and Madrid. The OC/EC minimum ratios observed at both sites were found to be between those of the tunnel and those of urban background air, suggesting that minimum values commonly obtained for this parameter in open urban atmospheres over-predict the direct emissions of OC(ff) from road transport. Possible reasons for this discrepancy are explored. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the structural and optical properties of Co-doped TiO2 thin films grown onto (0001)Al2O3 substrates by non-reactive pulsed laser deposition (PLD) using argon as buffer gas. It is shown that by keeping constant the substrate temperature at as low as 310 degrees C and varying only the background gas pressure between 7 Pa and 70 Pa, it is possible to grow either epitaxial rutile or pure anatase thin films, as well as films with a mixture of both polymorphs. The optical band gaps of the films are red shifted in comparison with the values usually reported for undoped TiO2, which is consistent with n-type doping of the TiO2 matrix. Such band gap red shift brings the absorption edge of the Co-doped TiO2 films into the visible region, which might favour their photocatalytic activity. Furthermore, the band gap red shift depends on the films' phase composition, increasing with the increase of the Urbach energy for increasing rutile content. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fatty acid profile of erythrocyte membranes has been considered a good biomarker for several pathologic situations. Dietary intake, digestion, absorption, metabolism, storage and exchange amongst compartments, greatly influence the fatty acids composition of different cells and tissues. Lipoprotein and hepatic lipases were also involved in fatty acid availability. In the present work we examined the correlations between fatty acid in Red Blood Cells (RBCs) membranes, the fatty acid desaturase and elongase activities, glycaemia, blood lipids, lipoproteins and apoproteins, and the endothelial lipase (EL) mass in plasma. Twenty one individuals were considered in the present study, with age >18 y. RBCs membranes were obtained and analysed for fatty acid composition by gas chromatography. The amount of fatty acids (as percentage) were analysed, and the ratios between fatty acid 16:1/16:0; 18:1/18:0; 18:0/16:0; 22:6 n-3/20:5 n-3 and 20:4 n-6/18:2 n-6 were calculated. Bivariate analysis (rs) and partial correlations were determined. SCD16 estimation activity correlated positively with BMI (rs=0.466, p=0.043) and triacylglycerols (TAG) (rs=0.483, p=0.026), and negatively with the ratio ApoA1/ApoB (rs=-0.566, p=0.007). Endothelial lipase (EL) correlated positively with the EPA/AA ratio in RBCs membranes (rs=0.524, p=0.045). After multi-adjustment for BMI, age, hs-CRP and dietary n3/n6 ratio, the correlations remained significant between EL and EPA/AA ratio. At the best of our knowledge this is the first report that correlated EL with the fatty acid profile of RBCs plasma membranes. The association found here can suggest that the enzyme may be involved in the bioavailability and distribution of n-3/n-6 fatty acids, suggesting a major role for EL in the pathophysiological mechanisms involving biomembranes’ fatty acids, such as in inflammatory response and eicosanoids metabolites pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de mestre em Engenharia Química e Biológica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the effect of ship speed and water depth on the propagation of ship generated waves. The ship is represented by a moving pressure distribution function at the free surface that is able to reproduce most of the phenomena involved in wave propagation. Results are obtained for a ship sailing along a coastal stretch made of a sloping bottom and a constant depth region. The results show that in the sloping bottom the crests of waves are bent along the slope and in the constant depth the standard Kelvin wave patterns can be found for the subcritical regime. In the critical regime the wave system is characterized by significant diverging waves and for a supercritical regime, the transverse waves disappear. © 2015 Taylor & Francis Group, London.