27 resultados para Non-Commutative Geometry

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: compliance with treatment is a common problem when treating amblyopic patients. Visual acuity of amblyopic eye does not improve without effective occlusive therapy. The aim of this study is to identify potential risk factors of non-compliance with treatment when it is implemented by family in amblyopic children. Setting: a quantitative transversal study was performed in a public hospital and in a private clinic in Lisbon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present results on the optimization of multilayered a-SiC:H heterostructures for wavelength-division (de) multiplexing applications. The non selective WDM device is a double heterostructure in a glass/ITO/a-SiC:H (p-i-n) /a-SiC:H(-p) /a-Si:H(-i')/a-SiC:H (-n')/ITO configuration. The single or the multiple modulated wavelength channels are passed through the device, and absorbed accordingly to its wavelength, giving rise to a time dependent wavelength electrical field modulation across it. The effect of single or multiple input signals is converted to an electrical signal to regain the information (wavelength, intensity and frequency) of the incoming photogenerated carriers. Here, the (de) multiplexing of the channels is accomplished electronically, not optically. This approach offers advantages in terms of cost since several channels share the same optical components; and the electrical components are typically less expensive than the optical ones. An electrical model gives insight into the device operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optically addressed read-write sensor based on two stacked p-i-n heterojunctions is analyzed. The device is a two terminal image sensing structure. The charge packets are injected optically into the p-i-n writer and confined at the illuminated regions changing locally the electrical field profile across the p-i-n reader. An optical scanner is used for charge readout. The design allows a continuous readout without the need for pixel-level patterning. The role of light pattern and scanner wavelengths on the readout parameters is analyzed. The optical-to-electrical transfer characteristics show high quantum efficiency, broad spectral response, and reciprocity between light and image signal. A numerical simulation supports the imaging process. A black and white image is acquired with a resolution around 20 mum showing the potentiality of these devices for imaging applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this review paper different designs based on stacked p-i'-n-p-i-n heterojunctions are presented and compared with the single p-i-n sensing structures. The imagers utilise self-field induced depletion layers for light detection and a modulated laser beam for sequential readout. The effect of the sensing element structure, cell configurations (single or tandem), and light source properties (intensity and wavelength) are correlated with the sensor output characteristics (light-to-dark sensivity, spatial resolution, linearity and S/N ratio). The readout frequency is optimized showing that scans speeds up to 104 lines per second can be achieved without degradation in the resolution. Multilayered p-i'-n-p-i-n heterostructures can also be used as wavelength-division multiplexing /demultiplexing devices in the visible range. Here the sensor element faces the modulated light from different input colour channels, each one with a specific wavelength and bit rate. By reading out the photocurrent at appropriated applied bias, the information is multiplexed or demultiplexed and can be transmitted or recovered again. Electrical models are present to support the sensing methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are concerned with providing more empirical evidence on forecast failure, developing forecast models, and examining the impact of events such as audit reports. A joint consideration of classic financial ratios and relevant external indicators leads us to build a basic prediction model focused in non-financial Galician SMEs. Explanatory variables are relevant financial indicators from the viewpoint of the financial logic and financial failure theory. The paper explores three mathematical models: discriminant analysis, Logit, and linear multivariate regression. We conclude that, even though they both offer high explanatory and predictive abilities, Logit and MDA models should be used and interpreted jointly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo desta investigação é compreender como é que alunos do 3.º ano de escolaridade desenvolvem o conceito de área com ênfase em conhecimentos sobre figuras e propriedades geométricas. Para melhor objetivar o estudo, formulei três questões que orientaram a investigação. Pretendo (1) compreender como é que os alunos mobilizam conhecimentos sobre as propriedades das figuras geométricas no estudo da área de uma figura plana? A que estratégias recorrem? Que dificuldades sentem? (2) que compreensão é que os alunos têm sobre o processo de medição? e (3) que ideias e/ou experiências são relevantes no desenvolvimento do conceito de área? Este é um estudo que se insere no paradigma interpretativo e que segue uma abordagem qualitativa, pelo que não visa generalização de resultados, mas uma descrição compreensiva dos processos vivenciados, tendo em conta os contextos pessoais e sociais. Optei por realizar dois Estudos de Caso. Os dados foram recolhidos através de fontes diversificadas, donde se destacam a observação participante e a análise de registos audiovisuais e escritos dos alunos. A análise dos dados teve por referência categorias criadas com base em contributos da literatura de referência. As conclusões desta investigação centram-se numa análise acerca das estratégias a que os alunos em estudo tendencialmente mais recorrem, visando também algumas das suas dificuldades mais relevantes e sobre as quais importa refletir. Destaca-se que ambos os alunos foram capazes de recorrer a raciocínios baseados e não baseados na medida, embora seja evidente uma tendência para raciocínios baseados na medida. É igualmente importante referir que os dois alunos revelaram um bom conhecimento acerca do processo de medição, mesmo quando ele implicava a definição de uma unidade de medida adequada e/ou mudança de unidade. É dado, também, destaque às experiências matemáticas que devem ser proporcionadas aos alunos no sentido do desenvolvimento de um conhecimento amplo e flexível do conceito de área. - Abstract The purpose of this investigation is to understand the development of 3rd year students’ concept of area based on their knowledge of geometrical properties and figures. As means to orientate the present study, the following investigation questions were formulated: 1) how do students use their knowledge about geometrical properties in order to understand geometrical shape’s areas? Which strategies do they use? What do they struggle with? (2) What is their understanding about measurement? And (3) what are the most relevant mathematical reasonings and classroom tasks in the development of the concept of area? This is a study that follows a qualitative approach: it does not intend to be a generalization, but a fully comprehensive description of the witnessed learning processes, bearing in mind the social and personal contexts. As such, two study-cases were developed. The data were collected through various sources, such as direct observation and analysis of audiovisual records or written worksheets. The scrutiny of the generated data was undertaken following criteria based on the literature of reference. The conclusions of this investigation are centered on the most used strategies as well as the students’ difficulties upon which it is important to discuss. It was noticed that the two students were able to use both measurement and non measurement thinking – although, preferably, they tend to use the first one. On the other hand, it is equally demonstrated that the two students have shown good acquaintance about measurement, even if obliged to the establishment of a suitable unit of measurement and/or change of units. At last, it is also referred which mathematical classroom tasks are important to develop a sustained and comprehensive concept of area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper was to introduce the symbolic formalism based on kneading theory, which allows us to study the renormalization of non-autonomous periodic dynamical systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last years it has become increasingly clear that the mammalian transcriptome is highly complex and includes a large number of small non-coding RNAs (sncRNAs) and long noncoding RNAs (lncRNAs). Here we review the biogenesis pathways of the three classes of sncRNAs, namely short interfering RNAs (siRNAs), microRNAs (miRNAs) and PIWI-interacting RNAs (piRNAs). These ncRNAs have been extensively studied and are involved in pathways leading to specific gene silencing and the protection of genomes against virus and transposons, for example. Also, lncRNAs have emerged as pivotal molecules for the transcriptional and post-transcriptional regulation of gene expression which is supported by their tissue-specific expression patterns, subcellular distribution, and developmental regulation. Therefore, we also focus our attention on their role in differentiation and development. SncRNAs and lncRNAs play critical roles in defining DNA methylation patterns, as well as chromatin remodeling thus having a substantial effect in epigenetics. The identification of some overlaps in their biogenesis pathways and functional roles raises the hypothesis that these molecules play concerted functions in vivo, creating complex regulatory networks where cooperation with regulatory proteins is necessary. We also highlighted the implications of biogenesis and gene expression deregulation of sncRNAs and lncRNAs in human diseases like cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conferência: 39th Annual Conference of the IEEE Industrial-Electronics-Society (IECON) - NOV 10-14, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do grau de Mestre em Educação Matemática na Educação Pré-Escolar e nos 1.º e 2.º Ciclos do Ensino Básico

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção do grau de Mestre em Educação Matemática na Educação Pré-escolar e nos 1º e 2º Ciclos do Ensino Básico

Relevância:

20.00% 20.00%

Publicador:

Resumo:

COPD is a major cause of morbidity and mortality worldwide, representing a major public health problem due to the high health and economic resource consumption. Pulmonary rehabilitation is a standard care recommendation for these patients, in order to control the symptoms and optimize the functional capacity, reducing health care costs associated with exacerbations and activity limitations and participation. However, in patients with severe COPD exercise performance can be difficult, due to extreme dyspnea, decreased muscle strength and fatigue. In addition, hypoxemia and dyspnea during efforts and daily activities may occur, limiting their quality of life. Thus, NIV have been used as adjunct to exercise, in order to improve exercise capacity in these patients. However, there is no consensus for this technique recommendation. Our objective was to verify whether the use of NIV during exercise is effective than exercise without NIV in dyspnea, walked distance, blood gases and health status in COPD patients, through a systematic review and meta-analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The urgent need to mitigate traffic problems such as accidents, road hazards, pollution and traffic jam have strongly driven the development of vehicular communications. DSRC (Dedicated Short Range Communications) is the technology of choice in vehicular communications, enabling real time information exchange among vehicles V2V (Vehicle-to-Vehicle) and between vehicles and infrastructure V2I (Vehicle-Infrastructure). This paper presents a receiving antenna for a single lane DSRC control unit. The antenna is a non-uniform array with five microstrip patches. The obtained beam width, bandwidth and circular polarization quality, among other characteristics, are compatible with the DSRC standards, making this antenna suitable for this application. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless communications are widely used for various applications, requiring antennas with different features. Often, to achieve the desired radiation pattern, is necessary to employ antenna arrays, using non-uniform excitation on its elements. Power dividers can be used and the best known are the T-junction and the Wilkinson power divider, whose main advantage is the isolation between output ports. In this paper the impact of this isolation on the overall performance of a circularly polarized planar antenna array using non-uniform excitation is investigated. Results show a huge decrease of the array bandwidths either in terms of return loss or in polarization, without resistors. © 2014 IEEE.