10 resultados para MRI CONTRAST AGENTS

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a multi-agent based simulation (MABS) framework to construct an artificial electric power market populated with learning agents. The artificial market, named TEMMAS (The Electricity Market Multi-Agent Simulator), explores the integration of two design constructs: (i) the specification of the environmental physical market properties and (ii) the specification of the decision-making (deliberative) and reactive agents. TEMMAS is materialized in an experimental setup involving distinct power generator companies that operate in the market and search for the trading strategies that best exploit their generating units' resources. The experimental results show a coherent market behavior that emerges from the overall simulated environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Ressonância Magnética

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As it is well known, competitive electricity markets require new computing tools for power companies that operate in retail markets in order to enhance the management of its energy resources. During the last years there has been an increase of the renewable penetration into the micro-generation which begins to co-exist with the other existing power generation, giving rise to a new type of consumers. This paper develops a methodology to be applied to the management of the all the aggregators. The aggregator establishes bilateral contracts with its clients where the energy purchased and selling conditions are negotiated not only in terms of prices but also for other conditions that allow more flexibility in the way generation and consumption is addressed. The aggregator agent needs a tool to support the decision making in order to compose and select its customers' portfolio in an optimal way, for a given level of profitability and risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cork processing wastewater is a very complex mixture of vegetal extracts and has, among other natural compounds, a very high content of phenolic/tannic colloidal matter that is responsible for severe environmental problems. In the present work, the concentration of this wastewater by nanofiltration was investigated with the aim of producing a cork tannin concentrate to be utilized in tanning. Permeation results showed that the permeate fluxes are controlled by both osmotic pressure and fouling/gel layer phenomena, leading to a rapid decrease of permeate fluxes with the concentration factor. The rejection coefficients to organic matter were higher than 95%, indicating that nanofiltration has a very good ability to concentrate the tannins and produce a permeate stream depleted from organic matter. The cork tannin concentrate obtained by nanofiltration and evaporation had total solids concentration of 34.8 g/l. The skins tanned by this concentrate were effectively converted to leather with a shrinking temperature of 7 degrees C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of amyloid structures is a neuropathological feature that characterizes several neurodegenerative disorders, such as Alzheimer´s and Parkinson´s disease. Up to now, the definitive diagnosis of these diseases can only be accomplished by immunostaining of post mortem brain tissues with dyes such Thioflavin T and congo red. Aiming at early in vivo diagnosis of Alzheimer´s disease (AD), several amyloid-avid radioprobes have been developed for b-amyloid imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The aim of this paper is to present a perspective of the available amyloid imaging agents, special those that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – A ressonância magnética (RM) mamária com injeção de contraste é uma ferramenta indispensável para a caracterização de lesões mamárias. Para tal, é fulcral uma boa capacidade de saturação de gordura de forma a delimitar as lesões observadas. Este trabalho tem como objetivo analisar quantitativa e qualitativamente as técnicas de saturação de gordura em RM mamária, nomeadamente as técnicas SPAIR e Dixon. Metodologia – Utilizou-se um equipamento de RM de 1,5T com bobina específica para a mama. Aplicou-se, durante o exame, uma sequência adicional em que a técnica de saturação de gordura utilizada foi a Dixon. Posteriormente foram analisadas as imagens obtidas com as técnicas SPAIR e Dixon e colocadas regiões de interesse (ROI) na lesão, na glândula mamária, no tecido adiposo e no ar. Estes valores de sinal obtidos foram registados e calcularam-se as relações sinal-ruído (SNR), contraste-ruído (CNR) e uniformidade de saturação de gordura para as mesmas estruturas a analisar e nas distintas sequências. Resultados – Verificou-se que a técnica de supressão de gordura Dixon apresenta resultados quantitativos e qualitativos superiores à técnica SPAIR. Conclusões – Recomenda-se a utilização da técnica Dixon para saturação de gordura nas sequências de estudo dinâmico com agente de contraste, especificamente nos estudos de RM mamária.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Ressonância Magnética

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antioneoplastic drugs are widely used in treatment of cancer, and several studies suggest acute and long-term effects associated to antineoplastic drug exposures, namely associating workplace exposure with health effects. Cytokinesis blocked micronucleus (CBMN) assay is one promising short-term genotoxicity assays for human risk assessment and their combination is recommended to monitor populations chronically exposed to genotoxic agents. The aim of this investigation is the genotoxicity assessment in different professionals that handle cytostatics drugs. This research is case-control blinded study constituted by 46 non-exposed subjects and 44 workers that handle antineoplastic drugs, such as pharmacists, pharmacy technicians, and nurses. It was found statistically significant increases in the genotoxicity biomarkers in exposed comparising with controls (p<0.05). The findings address the need for regular biomonitoring of personnel occupationally exposed to these drugs, confirming to an enhanced health risk assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).