41 resultados para Low-rise Residential Buildings
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Outlining the best strategies for seismic risk mitigation requires that both benefits and costs of retrofitting are known in advance. The assessment of the vulnerability of building typologies is a first step of a more extensive effort, concerning the analysis of the viability of seismic risk mitigation and taking into account retrofitting costs. The methodology adopted to obtain the seismic vulnerability of some classes of residential buildings existing in mainland Portugal is presented. This methodology is based on a structural analysis of individual buildings belonging to the same typology. An application example is presented to illustrate the methodology. Fragility curves of “boxed” building typology are also presented and broken down into three height classes: low rise, medium-rise and high-rise. These curves are based on average capacity spectra derived from several individual buildings belonging to the same typology.
Resumo:
Associado à escassez dos combustíveis fósseis e ao desejado controlo de emissões nocivas para a atmosfera, assistimos no mundo ao desenvolvimento do um novo paradigma — a mobilidade eléctrica. Apesar das variações de maior ou menor arbítrio político dos governos, do excelente ou débil desenvolvimento tecnológico, relacionados com os veículos eléctricos, estamos perante um caminho, no que diz respeito à mobilidade eléctrica, que já não deve ser encarado como uma moda mas como uma orientação para o futuro da mobilidade. Portugal tendo dado mostras que pretende estar na dianteira deste desafio, necessita equacionar e compreender em que condições existirá uma infra-estrutura nacional capaz de fazer o veículo eléctrico vingar. Assim, neste trabalho, analisa-se o impacto da mobilidade eléctrica em algumas dessas infra-estruturas, nomeadamente nos edifícios multi-habitacionais e redes de distribuição em baixa tensão. São criados neste âmbito, quatro perfis de carregamento dos EVs nomeadamente: nas horas de chegada a casa; nas horas de vazio com início programado pelo condutor; nas horas de vazio controlado por operador de rede (“Smart Grid”); e um cenário que contempla a utilização do V2G. Com a obrigação legal de nos novos edifícios serem instaladas tomadas para veículos eléctricos, é estudado, com os cenários anteriores a possibilidade de continuar a conceber as instalações eléctricas, sem alterar algumas das disposições legais, ao abrigo dos regulamentos existentes. É também estudado, com os cenários criados e com a previsão da venda de veículos eléctricos até 2020, o impacto deste novo consumo no diagrama de carga do Sistema Eléctrico Nacional. Mostra-se assim que a introdução de sistemas inteligentes de distribuição de energia [Smartgrid e vehicle to grid” (V2G)] deverá ser encarada como a solução que por excelência contribuirá para um aproveitamento das infra-estruturas existentes e simultaneamente um uso acessível para os veículos eléctricos.
Resumo:
O ruído é, por definição, um som desagradável ou indesejável que perturba o ambiente, contribuindo para o mal-estar físico e psíquico, podendo pôr em causa a saúde do ser humano. As situações de exposição nos espaços de repouso, lazer e trabalho a valores sonoros elevados, especialmente nos meios urbanos e suburbanos, têm-se multiplicado. Por outro lado, o desenvolvimento cultural dos cidadãos, cada vez mais cientes do direito à qualidade de vida, tem originado um aumento das exigências de conforto, influenciado directamente pela qualidade dos edifícios que habitam. Através da publicação do Regulamento Geral Sobre o Ruído – RGR – (aprovado pelo Decreto Lei nº251/87 de 24 de Junho) bem como o Regulamento dos Requisitos Acústicos dos Edifícios – RRAE - (aprovado pelo Decreto Lei nº129/02 de 11 de Maio), com as devidas alterações no Decreto-lei nº96/08, de 9 de Junho, foi permitido relacionar um conjunto de disposições normativas e legais, permitindo o estabelecimento de condições para a verificação das exigências fundamentais associadas ao conforto acústico dos edifícios (integração urbanística, isolamento sonoro a sons aéreos, isolamento a sons de percussão, exposição ao ruído durante o trabalho), justificando assim a necessidade da existência de regulamentação pelo facto da saúde dos indivíduos também se encontrar relacionada ao conforto acústico. Na presente dissertação, pretende-se dar um contributo para a elaboração da avaliação e certificação do comportamento acústico de edifícios de habitação através da definição dos principais aspectos a avaliar neste processo. Para tal, foi retratado o actual estado da arte e foi feito um levantamento das metodologias utilizadas pelas entidades acreditadas para os ensaios de acústica, tendo em conta a normalização e regulamentação existente, de maneira a obter o panorama destes diagnósticos de conforto acústico para a verificação da sua conformidade com as exigências regulamentares.
Resumo:
O sector dos edifícios é responsável por uma percentagem significativa dos consumos de energia primária e de energia eléctrica em Portugal, associada principalmente ao conforto térmico dos seus ocupantes. A União Europeia pretende uma redução de 20%, até 2020, dos consumos de energia e consequentes emissões de CO2 através da melhoria da eficiência energética dos edifícios públicos e residenciais. Em Portugal, o Plano Nacional para a Eficiência Energética (PNAEE) tem por objectivo obter uma poupança anual de energia de pelo menos 1% até ao ano de 2016, tomando como base a média de consumos de energia final, registados entre 2001 e 2005. Neste contexto, os edifícios anteriores a 1990 (primeira versão do RCCTE) podem apresentar um potencial significativo de melhoria da sua eficiência energética com base na sua reabilitação. Os edifícios “Gaioleiros” (1880 – 1930) constituindo uma parte importante do património histórico da cidade de Lisboa, para os quais a informação sobre o seu desempenho térmico é limitada, considerou-se pertinente efectuar um estudo destinado à sua caracterização experimental e numérica, face à especificidade do comportamento térmico das suas paredes caracterizadas pela elevada espessura. No presente trabalho, apresenta-se a metodologia e os resultados experimentais da medição da resistência térmica das paredes e da medição das necessidades térmicas de aquecimento da habitação. Estes resultados experimentais foram utilizados na validação do modelo de simulação térmica da habitação, que posteriormente serviu para avaliar as suas necessidades térmicas de aquecimento (Nic) e de arrefecimento (Nvc), identificar oportunidades de melhoria e avaliar o respectivo potencial de reabilitação. Neste trabalho, como contributos para uma reabilitação sustentável, apresentam-se avaliações de oportunidades de melhoria com base em estratégias de reforço do isolamento térmico. Dos resultados obtidos concluiu-se que melhorando o isolamento térmico das paredes e vãos envidraçados é possível baixar consideravelmente os consumos de energia associados à habitação, cumprindo assim as exigências estabelecidas no RCCTE ao nível dos requisitos de qualidade térmica da envolvente e consumos energéticos para edifícios novos e grandes reabilitações.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
Relatório de Estágio para obtenção do grau de mestre em Engenharia Civil na Área de Especialização de Edificações
Resumo:
Relatório de estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Coastal low-level jets (CLLJ) are a low-tropospheric wind feature driven by the pressure gradient produced by a sharp contrast between high temperatures over land and lower temperatures over the sea. This contrast between the cold ocean and the warm land in the summer is intensified by the impact of the coastal parallel winds on the ocean generating upwelling currents, sharpening the temperature gradient close to the coast and giving rise to strong baroclinic structures at the coast. During summertime, the Iberian Peninsula is often under the effect of the Azores High and of a thermal low pressure system inland, leading to a seasonal wind, in the west coast, called the Nortada (northerly wind). This study presents a regional climatology of the CLLJ off the west coast of the Iberian Peninsula, based on a 9km resolution downscaling dataset, produced using the Weather Research and Forecasting (WRF) mesoscale model, forced by 19 years of ERA-Interim reanalysis (1989-2007). The simulation results show that the jet hourly frequency of occurrence in the summer is above 30% and decreases to about 10% during spring and autumn. The monthly frequencies of occurrence can reach higher values, around 40% in summer months, and reveal large inter-annual variability in all three seasons. In the summer, at a daily base, the CLLJ is present in almost 70% of the days. The CLLJ wind direction is mostly from north-northeasterly and occurs more persistently in three areas where the interaction of the jet flow with local capes and headlands is more pronounced. The coastal jets in this area occur at heights between 300 and 400 m, and its speed has a mean around 15 m/s, reaching maximum speeds of 25 m/s.
Resumo:
This paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.
Resumo:
Motion compensated frame interpolation (MCFI) is one of the most efficient solutions to generate side information (SI) in the context of distributed video coding. However, it creates SI with rather significant motion compensated errors for some frame regions while rather small for some other regions depending on the video content. In this paper, a low complexity Infra mode selection algorithm is proposed to select the most 'critical' blocks in the WZ frame and help the decoder with some reliable data for those blocks. For each block, the novel coding mode selection algorithm estimates the encoding rate for the Intra based and WZ coding modes and determines the best coding mode while maintaining a low encoder complexity. The proposed solution is evaluated in terms of rate-distortion performance with improvements up to 1.2 dB regarding a WZ coding mode only solution.
Design of improved rail-to-rail low-distortion and low-stress switches in advanced CMOS technologies
Resumo:
This paper describes the efficient design of an improved and dedicated switched-capacitor (SC) circuit capable of linearizing CMOS switches to allow SC circuits to reach low distortion levels. The described circuit (SC linearization control circuit, SLC) has the advantage over conventional clock-bootstrapping circuits of exhibiting low-stress, since large gate voltages are avoided. This paper presents exhaustive corner simulation results of a SC sample-and-hold (S/H) circuit which employs the proposed and optimized circuits, together with the experimental evaluation of a complete 10-bit ADC utilizing the referred S/H circuit. These results show that the SLC circuits can reduce distortion and increase dynamic linearity above 12 bits for wide input signal bandwidths.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.
Resumo:
A Resolução do Conselho de Ministros n.º 120/2008, de 30 de Julho, definiu como prioridade estratégica para o País, no sector das comunicações electrónicas, a promoção do investimento em redes de nova geração. Com o objectivo de dar execução às orientações estratégicas estabelecidas, o Decreto -Lei n.º 123/2009, de 21 de Maio, veio estabelecer um conjunto de obrigações aplicáveis ao Estado, às Regiões Autónomas, às autarquias locais, empresas públicas, concessionárias e, genericamente, às entidades que detenham infra-estruturas que se integrem em domínio público, de forma a garantir a todas empresas de comunicações electrónicas, o acesso às infra-estruturas aptas ao alojamento de redes de comunicações electrónicas. Em Portugal, o caminho a ser traçado até as redes de nova geração passa pela, abertura eficaz e não discriminatória de todas as condutas e outras infra-estruturas aptas ao alojamento de redes de comunicações electrónicas, elaboração de regras técnicas aplicáveis às infra-estruturas de telecomunicações em loteamentos, urbanizações e conjuntos de edifícios, adopção de soluções que eliminem ou atenuem as barreiras verticais à instalação de fibra óptica e que evitem a monopolização do acesso aos edifícios pelo primeiro operador. Neste âmbito, excluem-se, pela sua especial natureza e fins a que estão afectas, as redes privativas dos órgãos políticos de soberania, do Ministério da Defesa Nacional, das forças e serviços de segurança, de emergência e de protecção civil. Assim, este trabalho visa apresentar procedimentos aplicáveis às infra-estruturas de telecomunicações para elaboração de um cadastro de todas as infra-estruturas, públicas e privadas, aptas ao alojamento de redes de comunicações electrónicas, e propor instruções técnicas para as condições e direitos de acesso, construção e intervenção sobre estas infra-estruturas.