3 resultados para Juice

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of monopolar and bipolar shaped pulses in additional yield of apple juice extraction is evaluated. The applied electric field strength, pulsewidth, and number of pulses are assessed for both pulse types, and divergences are analyzed. Variation of electric field strength is ranged from 100 to 1300 V/cm, pulsewidth from 20 to 300 mu s, and the number of pulses from 10 to 200, at a frequency of 200 Hz. Two pulse trains separated by 1 s are applied to apple cubes. Results are plotted against reference untreated samples for all assays. Specific energy consumption is calculated for each experiment as well as qualitative indicators for apple juice of total soluble dry matter and absorbance at 390-nm wavelength. Bipolar pulses demonstrated higher efficiency, and specific energetic consumption has a threshold where higher inputs of energy do not result in higher juice extraction when electric field variation is applied. Total soluble dry matter and absorbance results do not illustrate significant differences between application of monopolar and bipolar pulses, but all values are inside the limits proposed for apple juice intended for human consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Additional apple juice extraction with pulsed electric field pretreated apple cubes towards control samples is evaluated. Monopolar and bipolar shaped pulses are compared and their effect is studied with variation of electric field, pulse width and number of pulses. Variation of electric field strength is ranged from 100 V/cm to 1300 V/cm, pulse width from 20 mu s to 300 mu s and number of pulses from 10 to 200, at frequency of 200Hz. Two pulse trains separated by 1 second are applied to all samples. Bipolar pulses showed higher apple juice yields with all studied parameters. Calculation of specific energies consumed was assessed and a threshold where higher energy inputs do not increase juice yield is found for a number of used parameters. Qualitative parameters of total soluble matter (Brix) and absorbance at 390 nm wavelength were determined for each sample and results show that no substantial differences are found for PEF pre-treated and control samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A cintigrafia de perfusão do miocárdio (CPM) é um dos exames complementares de diagnóstico mais indicados na patologia cardiovascular. A atividade extramiocárdica é um problema recorrente na aquisição e avaliação da imagem. Parâmetros como o radiofármaco (RF) administrado, o tipo de esforço, a ingestão de alimentos, o posicionamento e o processamento de imagem influenciam a atividade extramiocárdica na CPM. O objetivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições das aquisições provocadas por este problema. Metodologia – Para a realização deste estudo, a população selecionada foram os Serviços de Medicina Nuclear (SMN) em Portugal Continental. Foram analisados 15 questionários, respondidos pelos Técnicos Coordenadores dos vários SMN. Foi realizada a associação do comportamento das variáveis, através da estatística descritiva e do Coeficiente de Correlação de Spearman. Resultados – A percentagem de repetições é menor com o uso da 99mTecnécio(Tc)-Tetrofosmina, aquisição de imagens tardias, ingestão de diversos alimentos (água, leite, sumo, pão com manteiga) e com a correção de atenuação. Conclusão – Os resultados obtidos demonstram que a maioria das soluções aplicadas nos SMN resultam numa diminuição das repetições.