62 resultados para Intrusion errors
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
A rock salt-lamprophyre dyke contact zone (sub-vertical, NE-SW strike) was investigated for its petrographic, mechanic and physical properties by means of anisotropy of magnetic susceptibility CAMS) and rock magnetic properties, coupled with quantitative microstructural analysis and thermal mathematical modelling. The quantitative microstructural analysis of halite texture and solid inclusions revealed good spatial correlation with AMS and halite fabrics. The fabrics of both lamprophyre and rock salt record the magmatic intrusion, "plastic" flow and regional deformation (characterized by a NW-SE trending steep foliation). AMS and microstructural analysis revealed two deformation fabrics in the rock salt: (1) the deformation fabrics in rock salt on the NW side of the dyke are associated with high temperature and high fluid activity attributed to the dyke emplacement; (2) On the opposite side of the dyke, the emplacement-related fabric is reworked by localized tectonic deformation. The paleomagnetic results suggest significant rotation of the whole dyke, probably during the diapir ascent and/or the regional Tertiary to Quaternary deformation. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a predictive optimal matrix converter controller for a flywheel energy storage system used as Dynamic Voltage Restorer (DVR). The flywheel energy storage device is based on a steel seamless tube mounted as a vertical axis flywheel to store kinetic energy. The motor/generator is a Permanent Magnet Synchronous Machine driven by the AC-AC Matrix Converter. The matrix control method uses a discrete-time model of the converter system to predict the expected values of the input and output currents for all the 27 possible vectors generated by the matrix converter. An optimal controller minimizes control errors using a weighted cost functional. The flywheel and control process was tested as a DVR to mitigate voltage sags and swells. Simulation results show that the DVR is able to compensate the critical load voltage without delays, voltage undershoots or overshoots, overcoming the input/output coupling of matrix converters.
Resumo:
In the Sparse Point Representation (SPR) method the principle is to retain the function data indicated by significant interpolatory wavelet coefficients, which are defined as interpolation errors by means of an interpolating subdivision scheme. Typically, a SPR grid is coarse in smooth regions, and refined close to irregularities. Furthermore, the computation of partial derivatives of a function from the information of its SPR content is performed in two steps. The first one is a refinement procedure to extend the SPR by the inclusion of new interpolated point values in a security zone. Then, for points in the refined grid, such derivatives are approximated by uniform finite differences, using a step size proportional to each point local scale. If required neighboring stencils are not present in the grid, the corresponding missing point values are approximated from coarser scales using the interpolating subdivision scheme. Using the cubic interpolation subdivision scheme, we demonstrate that such adaptive finite differences can be formulated in terms of a collocation scheme based on the wavelet expansion associated to the SPR. For this purpose, we prove some results concerning the local behavior of such wavelet reconstruction operators, which stand for SPR grids having appropriate structures. This statement implies that the adaptive finite difference scheme and the one using the step size of the finest level produce the same result at SPR grid points. Consequently, in addition to the refinement strategy, our analysis indicates that some care must be taken concerning the grid structure, in order to keep the truncation error under a certain accuracy limit. Illustrating results are presented for 2D Maxwell's equation numerical solutions.
Resumo:
Motion compensated frame interpolation (MCFI) is one of the most efficient solutions to generate side information (SI) in the context of distributed video coding. However, it creates SI with rather significant motion compensated errors for some frame regions while rather small for some other regions depending on the video content. In this paper, a low complexity Infra mode selection algorithm is proposed to select the most 'critical' blocks in the WZ frame and help the decoder with some reliable data for those blocks. For each block, the novel coding mode selection algorithm estimates the encoding rate for the Intra based and WZ coding modes and determines the best coding mode while maintaining a low encoder complexity. The proposed solution is evaluated in terms of rate-distortion performance with improvements up to 1.2 dB regarding a WZ coding mode only solution.
Resumo:
A competitividade entre as empresas e a busca por modelos de gestão e organização cada vez mais eficientes, tem dominado a actualidade. A filosofia de gestão Lean vem dar resposta a essas necessidades de aumento dos níveis de competitividade e eficiência, através de uma mudança da cultura organizacional, que assenta na redução ou eliminação de desperdícios e na melhoria contínua dos processos de fabrico de bens ou do fornecimento de serviços. A gestão Lean é suportada e implementada pela aplicação de um conjunto de ferramentas correctamente seleccionadas e adaptadas ao contexto organizacional da empresa ou organização. A presente dissertação visa caracterizar as ferramentas mais comuns da filosofia Lean, tendo em consideração a sua aplicabilidade na indústria e no sector dos serviços. É igualmente abordada a forma de aplicação das ferramentas Lean de maneira a que não constituam um acto isolado que conduz seguramente ao fracasso da implementação Lean na organização. Por essa razão são discutidas algumas regras e critérios, com base na proposta de um método de aplicação das ferramentas Lean que evite erros cometidos no passado e que levaram ao insucesso da aplicação do Lean em algumas organizações. Recorreu-se a um estudo de caso do ramo dos serviços, cujos resultados permitiram verificar a aplicabilidade do método proposto na aplicação de ferramentas Lean ao ramo dos serviços. O estudo de caso revelou a existência de uma elevada percentagem de desperdícios no processo em análise e permitiu melhorar o funcionamento desses mesmos processos. As melhorias alcançadas foram realizadas com base na eliminação dos desperdícios, na resolução de problemas e consequente uniformização de processos que melhoraram a qualidade e eficiência do serviço prestado, evidenciando que a organização alvo do estudo se encontra no bom caminho para atingir com sucesso a alteração da cultura organizacional para a filosofia Lean.
Resumo:
O desenvolvimento industrial, tecnológico e económico, conduziu ao aparecimento de soluções construtivas e de revestimentos disponíveis no mercado da construção, cada vez mais eficientes e economicamente vantajosas. Uma dessas soluções é o revestimento vinílico em pavimentos, utilizado a nível mundial principalmente em escritórios, hospitais e escolas. A sua resistência ao tráfego pedonal e facilidade de aplicação e manutenção fazem dele um revestimento de eleição. No entanto esta aparente versatilidade acaba por colocar dificuldades aos profissionais do projecto, da construção e da reabilitação de edifícios, em particular na escolha das melhores soluções para cada tipo de utilização. É pois importante que estes profissionais disponham de orientações práticas para que façam as suas escolhas de um modo objectivo. O presente trabalho propõe o desenvolvimento de uma análise aprofundada deste tipo de material, onde são abordadas as suas exigências funcionais, modo de aplicação e patologia associada, tentando evitar-se deste modo a ocorrência de eventuais erros sistemáticos e recorrentes.
Resumo:
When a paleomagnetic pole is sought for in an igneous body, the host rocks should be subjected to a contact test to assure that the determined paleopole has the age of the intrusion. If the contact test is positive, it precludes the possibility that the measured magnetization is a later effect. Therefore, we investigated the variations of the remanent magnetization along cross-sections of rocks hosting the Foum Zguid dyke (southern Morocco) and the dyke itself. A positive contact test was obtained, but it is mainly related with Chemical/Crystalline Remanent Magnetization due to metasomatic processes in the host-rocks during magma intrusion and cooling, and not only with Thermo-Remanent Magnetization as ordinarily assumed in standard studies. Paleomagnetic data obtained within the dyke then reflect the Earth magnetic field during emplacement of this well-dated (196.9 +/- 1.8 Ma) intrusion.
Resumo:
Knowledge on forced magma injection and magma flow in dykes is crucial for the understanding of how magmas migrate through the crust to the Earth's surface. Because many questions still persist, we used the long, thick, and deep-seated Foum Zguid dyke (Morocco) to investigate dyke emplacement and internal flow by means of magnetic methods, structural analysis, petrography, and scanning electron microscopy. We also investigated how the host rocks accommodated the intrusion. Regarding internal flow: 1. Important variations of the rock magnetic properties and magnetic fabric occur with distance from dyke wall; 2. anisotropy of anhysteretic remanent magnetization reveals that anisotropy of magnetic susceptibility (AMS) results mainly from the superposition of subfabrics with distinct coercivities and that the imbrication between magnetic foliation and dyke plane is more reliable to deduce flow than the orientation of the AMS maximum principal axis; and 3. a dominant upward flow near the margins can be inferred. The magnetic fabric closest to the dyke wall likely records magma flow best due to fast cooling, whereas in the core the magnetic properties have been affected by high-temperature exsolution and metasomatic effects due to slow cooling. Regarding dyke emplacement, this study shows that the thick forceful intrusion induced deformation by homogeneous flattening and/or folding of the host sedimentary strata. Dewatering related to heat, as recorded by thick quartz veins bordering the dyke in some localities, may have also helped accommodating dyke intrusion. The spatial arrangement of quartz veins and their geometrical relationship with the dyke indicate a preintrusive to synintrusive sinistral component of strike slip.
Resumo:
The effects of dyke intrusion on the magnetic properties of host sedimentary rocks are still poorly understood. Therefore, we have evaluated bulk magnetic parameters of standard palaeomagnetic samples collected along several sections across the sediments hosting the Foum Zguid dyke in southern Morocco. The study has been completed with the evaluation of the magnetic fabric after laboratory application of sequential heating experiments. The present study shows that: (1) close to Fourn Zguid dykes, the variations of the bulk magnetic parameters and of the magnetic fabric is strongly related with re-crystallization and Fe-metasomatism intensity. (2) The thermal experiments on AMS of samples collected farther from the dyke and, thus, less affected by heating during dyke emplacement, indicate that 300-400 degrees C is the minimum experimental temperature necessary to trigger appreciable transformations of the pre-existing magnetic fabrics. For temperatures higher than ca. 580 degrees C, the magnetic fabric transformations are fully realized, with complete transposition of the initial fabric to a fabric similar to that of samples collected close to the dyke. Therefore, measured variations of the magnetic fabric can be used to evaluate re-crystallization temperatures experienced by the host sedimentary rock during dyke emplacement. The distinct magnetic behaviour observed along the cross-sections strongly suggests that samples collected farther from the dyke margins did not experience thermal episodes with temperatures higher than 300 degrees C after dyke emplacement. (3) AMS data shows a gradual variation of the magnetic fabric with distance from the dyke margin, from sub-horizontal K-3 away from the dyke to vertical K3 close to the dyke. Experimental heating shows that heat alone can be responsible for this strong variation. Therefore, such orientation changes should not be unequivocally interpreted as the result of a stress field (resulting from the emplacement of the dyke, for instance). (4) Magnetic studies prove to be a very sensitive tool to assess rock magnetic transformations, thermally and chemically induced by dyke intrusion in hosting sediments.
Resumo:
The only Iberian lower Jurassic palcomagnetic pole come from the "Central Atlantic Magmatic Province"-related Messejana Plasencia dyke, but the age and origin of its remanence have been a matter of discussion. With the aim of solving this uncertainty, and to go further into a better understanding of its emplacement and other possible tectonic features, a systematic paleomagnetic investigation of 40 sites (625 specimens) distributed all along the 530 kin of the Messejana Plasencia dyke has been carried out. Rock magnetic experiments indicate PSD low Ti-titanomagnetite and magnetite as the minerals carrying the NRM. The samples were mostly thermally demagnetized. Most sites exhibit a characteristic remanent component of normal polarity with the exception of two sites, where samples with reversed polarities have been observed. The paleomagnetic pole derived from a total of 35 valid sites is representative of the whole structure of the dyke, and statistically well defined, with values of PLa = 70.4 degrees N, PLo = 237.6 degrees E, K= 47.9 and A(95) = 3.5 degrees. Paleomagnetic data indicates that: (i) there is no evidence of a Cretaceous remagnetization in the dyke, as it was suggested; (ii) most of the dyke had a brief emplacement time; furthermore, two dyke intrusion events separated in time from it by at least 10,000 y have been detected; (iii) the high grouping of the VGPs directions suggests no important tectonic perturbations of the whole structure of the dyke since its intrusion time; (iv) the pole derived from this study is a good quality lower Jurassic paleopole for the Iberian plate; and (v) the Messejana Plasencia dyke paleopole for the Iberian plate is also in agreement with quality-selected European and North American lower Jurassic paleopoles and the magnetic anomalies data sets that are available for rotate them to Iberia.
Resumo:
Recent literature has proved that many classical pricing models (Black and Scholes, Heston, etc.) and risk measures (V aR, CV aR, etc.) may lead to “pathological meaningless situations”, since traders can build sequences of portfolios whose risk leveltends to −infinity and whose expected return tends to +infinity, i.e., (risk = −infinity, return = +infinity). Such a sequence of strategies may be called “good deal”. This paper focuses on the risk measures V aR and CV aR and analyzes this caveat in a discrete time complete pricing model. Under quite general conditions the explicit expression of a good deal is given, and its sensitivity with respect to some possible measurement errors is provided too. We point out that a critical property is the absence of short sales. In such a case we first construct a “shadow riskless asset” (SRA) without short sales and then the good deal is given by borrowing more and more money so as to invest in the SRA. It is also shown that the SRA is interested by itself, even if there are short selling restrictions.
Resumo:
The growth experimented in recent years in both the variety and volume of structured products implies that banks and other financial institutions have become increasingly exposed to model risk. In this article we focus on the model risk associated with the local volatility (LV) model and with the Variance Gamma (VG) model. The results show that the LV model performs better than the VG model in terms of its ability to match the market prices of European options. Nevertheless, both models are subject to significant pricing errors when compared with the stochastic volatility framework.
Resumo:
O Código dos contratos públicos (CCP) veio introduzir alguns novos conceitos, nas empreitadas de obras públicas, sobre erros e omissões e também sobre trabalhos a mais. Tais conceitos têm estado na origem de algumas polémicas envolvendo donos de obra, projectistas, fiscalizações, empreiteiros e técnicos. Por outro, quer à luz da anterior legislação quer ao abrigo da actual os desvios de preço e prazo, em empreitadas de obras públicas, continuam a ser frequentes, dir-se-á mesmo, praticamente uma constante e frequentemente alvo nos meios de comunicação. No âmbito desta dissertação pretende-se partilhar algumas reflexões emergentes da observação efectuada, como participante activo em diversos empreendimentos. Verificar-se-á ao longo da mesma dissertação que nela é atribuída grande relevância ao programa preliminar constante do Anexo I à Portaria n.º 701-H/2008 de 29 de Julho, que dá origem ao projecto. Com efeito, este documento embora a sua designação de preliminar possa induzir em erro, levando a conferir-lhe pouca importância, é, em boa verdade, o programa fundamental, para um bom entendimento entre o dono de obra e o projectista e subsequentemente com o empreiteiro. Nesta dissertação faz-se uma incursão pelos conteúdos mais relevantes do CCP, no âmbito dos desvios de preço e custo, das empreitadas de obras públicas. Procede-se, também, a uma análise detalhada e sequencial das fases e actividades que contribuem para a concretização de uma obra pública, observando simultaneamente o papel dos diversos intervenientes.
Resumo:
Introdução – Na avaliação diagnóstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnóstico. Objetivo – Descrever a importância da perceção visual na análise da mamografia, identificando os principais fatores que contribuem para a perceção visual do radiologista e que condicionam a acuidade diagnóstica. Metodologia – Estudo descritivo baseado numa revisão sistemática de literatura através da PubMed e da Science Direct. Foram incluídos 42 artigos que respeitavam, pelo menos, um dos critérios de inclusão no estudo. Para a seleção das referências foi utilizada a metodologia PRISMA, constituída por 4 fases: identificação, seleção preliminar, elegibilidade e estudos incluídos. Resultados – Na avaliação diagnóstica em mamografia, a perceção visual está intimamente relacionada com: 1) diferentes parâmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e à luminância e movimentos oculares); 2) com condições de visualização de uma imagem (iluminância da sala e luminância do monitor); e 3) fadiga ocular provocada pela observação diária consecutiva de imagens. Conclusões – A perceção visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (lesões não são fixadas pela fóvea), erros de reconhecimento (lesões fixadas, mas não durante o tempo suficiente) e erros de decisão (lesões fixadas, mas não identificadas como suspeitas). Os estudos analisados sobre perceção visual, atenção visual e estratégia visual, bem como os estudos sobre condições de visualização não caracterizam a função visual dos observadores. Para uma avaliação correta da perceção visual em mamografia deverão ser efetuados estudos que correlacionem a função visual com a qualidade diagnóstica. ABSTRACT - Introduction – Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims – To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods – In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results – Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions – Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observer’s visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.
Resumo:
Proper lighting is a prerequisite for obtaining a good working environment. Good lighting includes quantity and quality requirements, and should necessarily be appropriate to the activity/task being carried out, bearing in mind the comfort and visual efficiency of the worker. Apart from the advantages in the health and welfare for the workers, good lighting also leads to better job performance (faster), less errors, better safety, fewer accidents and less absenteeism. The overall effect is: better productivity.