14 resultados para HETEROGENEITY

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work addresses the present-day (<100 ka) mantle heterogeneity in the Azores region through the study of two active volcanic systems from Terceira Island. Our study shows that mantle heterogeneities are detectable even when "coeval" volcanic systems (Santa Barbara and Fissural) erupted less than 10 km away. These volcanic systems, respectively, reflect the influence of the Terceira and D. Joao de Castro Bank end-members defined by Beier et at (2008) for the Terceira Rift Santa Barbara magmas are interpreted to be the result of mixing between a HIMU-type component, carried to the upper mantle by the Azores plume, and the regional depleted MORB magmas/source. Fissural lavas are characterized by higher Ba/Nb and Nb/U ratios and less radiogenic Pb-206/Pb-204, Nd-143/Nd-144 and Hf-176/Hf-177, requiring the small contribution of delaminated sub-continental lithospheric mantle residing in the upper mantle. Published noble gas data on lavas from both volcanic systems also indicate the presence of a relatively undegassed component, which is interpreted as inherited from a lower mantle reservoir sampled by the ascending Azores plume. As inferred from trace and major elements, melting began in the garnet stability field, while magma extraction occurred within the spinel zone. The intra-volcanic system's chemical heterogeneity is mainly explained by variable proportions of the above-mentioned local end-members and by crystal fractionation processes. (C) 2011 Elsevier By. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim - To use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for (125)I prostate implants. Background - Dose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect. Materials and Methods - The computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose-volume histograms and EUD for the prostate and rectum. Results - The mean absorbed doses presented deviations of 3.3-4.0% for the prostate and of 2.3-4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D 90 was overestimated by 2.8-3.9% and the rectum D 0.1cc resulted in dose differences of 6-8%. The EUD resulted in an overestimation of 3.5-3.7% for the prostate and of 7.7-8.3% for the rectum. Conclusions - The deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deuterium NMR was used to investigate the orientational order in a composite cellulosic formed by liquid crystalline acetoxypropylcellulose (A PC) and demented nematic 4'-penty1-4-cyanobiphenyl (5CB-4 alpha d(2)) with the per centage of 85% A PC by weight Three forms of the composite including electro spun microfibers, thin film and bulk samples were analyzed The NMR results initially suggest two distinct scenarios, one whet e the 503-alpha d(2), is confined to small droplets with dimensions smaller than the magnetic coherence length and the other where the 503-alpha d(2) molecules arc aligned with the A PC network chains Polarized optical microscopy (POW from thin film samples along with all the NMR results show the presence of 5CB-alpha d(2) droplets in the composite systems with a nematic wetting layer at the APC-5CB-alpha d(2) interface that experiences and order disorder transition driven by the polymer network N-I transition The characterization of the APC network I-N transition shows a pronounced subcritical behavior within a heterogeneity scenario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução - A prevalência da doença pulmonar obstrutiva crónica (DPOC) apresenta valores muito heterogéneos em todo o mundo. A iniciativa Burden of Obstructive Lung Disease (BOLD) foi desenvolvida para que a prevalência da DPOC possa ser avaliada com metodologia uniformizada. O objetivo deste estudo foi estimar a prevalência da DPOC em adultos com 40 ou mais anos numa população alvo de 2 700 000 habitantes na região de Lisboa, de acordo com o protocolo BOLD. Métodos - A amostra foi estratificada de forma aleatória multifaseada selecionando-se 12 freguesias. O inquérito compreendia um questionário com informação sobre fatores de risco para a DPOC e doença respiratória autoreportada; adicionalmente, foi efetuada espirometria com prova de broncodilatação. Resultados - Foram incluídos 710 participantes com questionário e espirometria aceitáveis. A prevalência estimada da DPOC na população no estadio GOLD I+ foi de 14,2% (IC 95%: 11,1; 18,1) e de 7,3% no estadio ii+ (IC 95%: 4,7; 11,3). A prevalência não ajustada foi de 20,2% (IC 95%: 17,4; 23,3) no estadio i+ e de 9,5% (IC 95%: 7,6; 11,9) no estadio ii+. A prevalência da DPOC no estadio GOLD II+ aumentou com a idade, sendo mais elevada no sexo masculino. A prevalência estimada da DPOC no estadio GOLD I+ foi de 9,2% (IC 95%: 5,9; 14,0) nos não fumadores versus 27,4% (IC 95%: 18,5; 38,5) nos fumadores com carga tabágica de ≥ 20 Unidades Maço Ano. Detetou-se uma fraca concordância entre a referência a diagnóstico médico prévio e o diagnóstico espirométrico, com 86,8% de subdiagnósticos. Conclusões - O achado de uma prevalência estimada da DPOC de 14,2% sugere que esta é uma doença comum na região de Lisboa, contudo com uma elevada proporção de subdiagnósticos. Estes dados apontam para a necessidade de aumentar o grau de conhecimento dos profissionais de saúde sobre a DPOC, bem como a necessidade de maior utilização da espirometria nos cuidados de saúde primários.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the actual world, the impact of the software buying decisions has a rising relevance in social and economic terms. This research tries to explain it focusing on the organizations buying decisions of Operating Systems and Office Suites for personal computers and the impact on the competition between incumbent and alternative players in the market in these software categories, although the research hypotheses and conclusions may extend to other software categories and platforms. We concluded that in this market beside brand image, product features or price, other factors could have influence in the buying choices. Network effect, switching costs, local network effect, lock-in or consumer heterogeneity all have influence in the buying decision, protecting the incumbent and making it difficult for the competitive alternatives, based mainly on product features and price, to gain market share to the incumbent. This happens in a stronger way in the Operating Systems category.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In man brain cancer is an aggressive, malignant form of tumour, it is highly infiltrative in nature, is associated with cellular heterogeneity and affects cerebral hemispheres of the brain. Current drug therapies are inadequate and an unmet clinical need exists to develop new improved therapeutics. The ability to silence genes associated with disease progression by using short interfering RNA (siRNA) presents the potential to develop safe and effective therapies. In this work, in order to protect the siRNA from degradation, promote cell specific uptake and enhance gene silencing efficiency, a PEGylated cyclodextrin (CD)-based nanoparticle, tagged with a CNS-targeting peptide derived from the rabies virus glycoprotein (RVG) was formulated and characterized. The modified cyclodextrin derivatives were synthesized and co-formulated to form nanoparticles containing siRNA which were analysed for size, surface charge, stability, cellular uptake and gene-knockdown in brain cancer cells. The results identified an optimised co-formulation prototype at a molar ratio of 1:1.5:0.5 (cationic cyclodextrin:PEGylated cyclodextrin:RVG-tagged PEGylated cyclodextrin) with a size of 281±39.72nm, a surface charge of 26.73±3mV, with efficient cellular uptake and a 27% gene-knockdown ability. This CD-based formulation represents a potential nanocomplex for systemic delivery of siRNA targeting brain cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Centrado na acção de liderança, este estudo propôs-se identificar as contingências e imperativos inerentes ao processo de implementação do programa TEIP num agrupamento de escolas. Especificamente, pretendeu-se captar a heterogeneidade das lógicas de mudança e identificar modos de apropriação subjectiva da liderança pedagógica e organizacional. Os resultados reforçam a ideia de que implementar um programa novo é construção de complexidade holística, implicando a conjunção integrada de múltiplas estratégias de liderança. Discutem-se os resultados à luz das teorizações iniciais, com relevo para as lógicas de prestação de contas e alguns sinais de „balcanização‟ organizacional.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose - The education and training of a nuclear medicine technologist (NMT) is not homogeneous among European countries, which leads to different scope of practices and, therefore, different technical skills are assigned. The goal of this research was to characterize the education and training of NMT in Europe. Materials and methods - This study was based on a literature research to characterize the education and training of NMT and support the historical evolution of this profession. It was divided into two different phases: the first phase included analysis of scientific articles and the second phase included research of curricula that allow health professionals to work as NMT in Europe. Results - The majority of the countries [N=31 (89%)] offer the NMT curriculum integrated into the high education system and only in four (11%) countries the education is provided by professional schools. The duration in each education system is not equal, varying in professional schools (2-3 years) and high education level system (2-4 years), which means that different European Credit Transfer and Accumulation System, such as 240, 230, 222, 210 or 180 European Credit Transfer and Accumulation System, are attributed to the graduates. The professional title and scope of the practice of NMT are different in different countries in Europe. In most countries of Europe, nuclear medicine training is not specific and curriculum does not demonstrate the Nuclear Medicine competencies performed in clinical practice. Conclusion - The heterogeneity in education and training for NMT is an issue prevalent among European countries. For NMT professional development, there is a huge need to formalize and unify educational and training programmes in Europe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The growing heterogeneity of networks, devices and consumption conditions asks for flexible and adaptive video coding solutions. The compression power of the HEVC standard and the benefits of the distributed video coding paradigm allow designing novel scalable coding solutions with improved error robustness and low encoding complexity while still achieving competitive compression efficiency. In this context, this paper proposes a novel scalable video coding scheme using a HEVC Intra compliant base layer and a distributed coding approach in the enhancement layers (EL). This design inherits the HEVC compression efficiency while providing low encoding complexity at the enhancement layers. The temporal correlation is exploited at the decoder to create the EL side information (SI) residue, an estimation of the original residue. The EL encoder sends only the data that cannot be inferred at the decoder, thus exploiting the correlation between the original and SI residues; however, this correlation must be characterized with an accurate correlation model to obtain coding efficiency improvements. Therefore, this paper proposes a correlation modeling solution to be used at both encoder and decoder, without requiring a feedback channel. Experiments results confirm that the proposed scalable coding scheme has lower encoding complexity and provides BD-Rate savings up to 3.43% in comparison with the HEVC Intra scalable extension under development. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de Prática Profissional Supervisionada, Mestrado em Educação Pré-Escolar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório da Prática Profissional Supervisionada Mestrado em Educação Pré-Escolar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O cancro do ovário é a neoplasia ginecológica com maior índice de mortalidade entre a população do sexo feminino apesar dos consideráveis progressos verificados no seu tratamento. Caso o diagnóstico seja precoce, a taxa de sobrevida é bastante elevada, mas o cancro do ovário primário é assintomático e na maioria das vezes só é diagnosticado numa fase avançada da doença, resultando num prognóstico pouco favorável. A falta de especificidade das modalidades terapêuticas associada à heterogeneidade das células oncológicas tem limitado a terapia do cancro do ovário. Alguns dos avanços clínicos mais promissores no tratamento do cancro são as terapêuticas dirigidas a alvos específicos, especialmente proteínas sobre expressas em vários tipos de células epiteliais. Neste contexto, a radioimunoterapia com anticorpos monoclonais tem sido explorada nos carcinomas epiteliais que constituem cerca de 90% das neoplasias do ovário. Esta estratégia terapêutica, que tira partido da ação combinada da radiotoxicidade associada aos radionuclídeos para terapia e dos efeitos citotóxicos do anticorpo, pode constituir uma alternativa às terapias convencionais, potenciando a eficácia do tratamento. Neste artigo são abordados aspetos relacionados com o cancro do ovário, nomeadamente o seu diagnóstico e terapia. São ainda revistos, de forma breve, alguns estudos clínicos em que a eficácia de anticorpos monoclonais marcados com radionuclídeos para terapêutica foi avaliada no cancro do ovário.