35 resultados para Difference between genders

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia cardiovascular

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Formaldehyde, classified by the IARC as carcinogenic in humans and experimental animals, is a chemical agent that is widely used in histopathology laboratories. The exposure to this substance is epidemiologically linked to cancer and to nuclear changes detected by the cytokinesis-block micronucleus test (CBMN). This method is extensively used in molecular epidemiology, since it provides information on several biomarkers of genotoxicity, such as micronuclei (MN), which are biomarkers of chromosomes breakage or loss, nucleoplasmic bridges (NPB), common biomarkers of chromosome rearrangement, poor repair and/or telomere fusion, and nuclear buds (NBUD), biomarkers of elimination of amplified DNA. The aim of this study is to compare the frequency of genotoxicity biomarkers, provided by the CBMN assay in peripheral lymphocytes and the MN test in buccal cells, between individuals occupationally exposed and non-exposed to formaldehyde and other environmental factors, namely tobacco and alcohol consumption. The sample comprised two groups: 56 individuals occupationally exposed to formaldehyde (cases) and 85 unexposed individuals (controls), from whom both peripheral blood and exfoliated epithelial cells of the oral mucosa were collected in order to measure the genetic endpoints proposed in this study. The mean level of TWA8h was 0.16±0.11ppm (differences between genders. As for age, only the mean MN frequency in lymphocytes was found significantly higher in elderly people among the exposed groups (p = 0.006), and there was also evidence of an interaction between age and gender with regards to that biomarker in those exposed. Smoking habits did not influence the frequency of the biomarkers, whereas alcohol consumption only influenced the MN frequency in lymphocytes in controls (p = 0.011), with drinkers showing higher mean values. These results provide evidence of the association between occupational exposure to formaldehyde and the presence of genotoxicity biomarkers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Em resposta ao predomínio da heteronormatividade nos estudos sobre o trabalho doméstico, este artigo explora a forma como este é organizado e distribuído em casais do mesmo sexo. Para esse efeito, desenvolveu-se uma pesquisa qualitativa (20 entrevistas aos membros de casais homossexuais) em torno dos desequilíbrios, do processo de negociação, do nível de satisfação, e ainda da herança familiar genderizada na actual organização do trabalho doméstico. Concluiu-se que a ausência da diferença de sexo no casal contribui para uma mais flexível e paritária negociação da organização das tarefas. Reflexo da socialização de género, as mulheres tendem para uma maior especialização e os homens para uma maior delegação das tarefas. In response to the predominance of heteronormativity in the studies on the household labour, this article explores the way it is organized and distributed in same-sex couples. Qualitative research was carried out on the basis of 20 interviews with members of homosexual couples, and informationwas collected on the imbalances, negotiation, satisfaction and gendered family legacy in the current organization of household labour. Results show that the absence of the sex difference between the members of the couple contributes to more flexible and egalitarian negotiation in the organization of chores. As a consequence of gender socialization, women tend to specialize and men to delegate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Opposite enantiomers exhibit different NMR properties in the presence of an external common chiral element, and a chiral molecule exhibits different NMR properties in the presence of external enantiomeric chiral elements. Automatic prediction of such differences, and comparison with experimental values, leads to the assignment of the absolute configuration. Here two cases are reported, one using a dataset of 80 chiral secondary alcohols esterified with (R)-MTPA and the corresponding 1H NMR chemical shifts and the other with 94 13C NMR chemical shifts of chiral secondary alcohols in two enantiomeric chiral solvents. For the first application, counterpropagation neural networks were trained to predict the sign of the difference between chemical shifts of opposite stereoisomers. The neural networks were trained to process the chirality code of the alcohol as the input, and to give the NMR property as the output. In the second application, similar neural networks were employed, but the property to predict was the difference of chemical shifts in the two enantiomeric solvents. For independent test sets of 20 objects, 100% correct predictions were obtained in both applications concerning the sign of the chemical shifts differences. Additionally, with the second dataset, the difference of chemical shifts in the two enantiomeric solvents was quantitatively predicted, yielding r2 0.936 for the test set between the predicted and experimental values.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, 14 primary schools of Lisbon city, Portugal, followed a questionnaire of the ISAAC - International Study of Asthma and Allergies in Childhood Program, in 2009/2010. The questionnaire contained questions to identify children with respiratory diseases (wheeze, asthma and rhinitis). Total particulate matter (TPM) was passively collected inside two classrooms of each of 14 primary schools. Two types of filter matrices were used to collect TPM: Millipore (IsoporeTM) polycarbonate and quartz. Three campaigns were selected for the measurement of TPM: Spring, Autumn and Winter. The highest difference between the two types of filters is that the mass of collected particles was higher in quartz filters than in polycarbonate filters, even if their correlation is excellent. The highest TPM depositions occurred between October 2009 and March 2010, when related with rhinitis proportion. Rhinitis was found to be related to TPM when the data were grouped seasonally and averaged for all the schools. For the data of 2006/2007, the seasonal variation was found to be related to outdoor particle deposition (below 10 μm).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Seismic recordings of IRIS/IDA/GSN station CMLA and of several temporary stations in the Azores archipelago are processed with P and S receiver function (PRF and SRF) techniques. Contrary to regional seismic tomography these methods provide estimates of the absolute velocities and of the Vp/Vs ratio up to a depth of similar to 300 km. Joint inversion of PRFs and SRFs for a few data sets consistently reveals a division of the subsurface medium into four zones with a distinctly different Vp/Vs ratio: the crust similar to 20 km thick with a ratio of similar to 1.9 in the lower crust, the high-Vs mantle lid with a strongly reduced VpNs velocity ratio relative to the standard 1.8, the low-velocity zone (LVZ) with a velocity ratio of similar to 2.0, and the underlying upper-mantle layer with a standard velocity ratio. Our estimates of crustal thickness greatly exceed previous estimates (similar to 10 km). The base of the high-Vs lid (the Gutenberg discontinuity) is at a depth of-SO km. The LVZ with a reduction of S velocity of similar to 15% relative to the standard (IASP91) model is terminated at a depth of similar to 200 km. The average thickness of the mantle transition zone (TZ) is evaluated from the time difference between the S410p and SKS660p, seismic phases that are robustly detected in the S and SKS receiver functions. This thickness is practically similar to the standard IASP91 value of 250 km. and is characteristic of a large region of the North Atlantic outside the Azores plateau. Our data are indicative of a reduction of the S-wave velocity of several percent relative to the standard velocity in a depth interval from 460 to 500 km. This reduction is found in the nearest vicinities of the Azores, in the region sampled by the PRFs, but, as evidenced by SRFs, it is missing at a distance of a few hundred kilometers from the islands. We speculate that this anomaly may correspond to the source of a plume which generated the Azores hotspot. Previously, a low S velocity in this depth range was found with SRF techniques beneath a few other hotspots.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents preliminary results in the study of a novel structure for a laser scanned photodiode (LSP) type of image sensor. In order to increase the signal output, a stacked p-i-n-p-i-n structure with an intermediate light-blocking layer is used. The image and the scanning beam are incident through opposite sides of the sensor and their absorption is kept in separate junctions by an intermediate light-blocking layer. As in the usual LSP structure the scanning beam-induced photocurrent is dependent on the local illumination conditions of the image. The main difference between the two structures arises from the fact that in this new structure the image and the scanner have different optical paths leading to an increase in the photocurrent when the scanning beam is incident on a region illuminated on the image side of the sensor, while a decreasing in the photocurrent was observed in the single junction LSP. The results show that the structure can be successfully used as an image sensor even though some optimization is needed to enhance the performance of the device.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although a great body of literature exists concerning the ingestion of food contaminated with aflatoxin, there are still few studies regarding mycotoxin inhalation in occupational settings. Since mycotoxins are relatively non-volatile, inhalation exposure is cause by inhalation of airborne fungal particulates or fungi-contaminated substrates that contain aflatoxin. We intend to know if there is occupational exposure to aflatoxin in Portuguese poultry and swine production. A total of 19 individuals (11 swine; 8 poultry) agreed and provided blood samples during the course of this investigation. Measurement of AFB1 was performed by ELISA. The samples were treated with pronase (Merck), wash in a Column C18 and purification was made with immunoaffinity columns (R.biopharma), specific for AFB1. It was applied statistical test (Mann-Whitney) to verified statistical difference in AFB1 results between the two settings. Results varied with concentrations from difference between the two occupational settings, however, results reveal a tendency for poultry workers have higher aflatoxin values, probably because poultry activities are promoter of particles exposure. Only women’s in both settings have results differences in the activities performed. Exposure to air and dust containing aflatoxin by inhalation should be consider a route of exposure in both settings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introdução – A medição da pressão arterial (PA), utilizando dispositivos automáticos, é frequentemente realizada na prática clínica e na automedição, permitindo adquirir informação fiável para o diagnóstico, controlo e tratamento da hipertensão arterial. Porém, muitos dos dispositivos automáticos disponíveis no mercado não estão validados segundo protocolos existentes para o efeito. O objetivo do estudo foi confirmar a validação do dispositivo de medição automática da PA, OMRON® M6 Comfort, segundo o Protocolo Internacional da European Society of Hypertension (ESH), de 2010, para a validação de dispositivos de medição automática da PA em adultos. Metodologia – Foram estudados 33 indivíduos, aos quais foram realizadas 9 medições sequenciais da PA, no braço esquerdo, com um esfignomanómetro aneróide alternando com o dispositivo automático. Seguidamente avaliaram-se as diferenças entre os valores obtidos pelos dispositivos para a pressão arterial sistólica (PAS) e diastólica (PAD), classificando-as em três níveis (≤ 5, ≤ 10 ou ≤ 15 mmHg). O número das diferenças em cada nível foi comparado ao requerido pelo Protocolo (fase 1.1). Para cada sujeito foi ainda determinado o número de diferenças com valores ≤ 5 mmHg. Pelo menos 24 dos 33 indivíduos devem ter 2 ou 3 diferenças com valores ≤ 5 mmHg e no máximo 3 dos 33 indivíduos podem apresentar as 3 diferenças com valores > 5 mmHg (fase 1.2). Resultados – O dispositivo OMRON® M6 Comfort foi aprovado nas fases 1.1 e 1.2 para a PAS e PAD. A média das diferenças entre as medições da PA, determinada pelos dispositivos automático e manual, foi de -0,82 ± 5,62 mmHg para a PAS e 2,14 ± 5,15 mmHg para a PAD. Considerações Finais – O dispositivo OMRON® M6 Comfort é válido para a medição da PA em adultos, de acordo com o Protocolo Internacional da ESH, de 2010. - ABSTRACT - Introduction – The measurement of blood pressure (BP) using automatic devices is often performed in clinical practice and self-measurement allowing the acquisition of reliable information for the diagnosis, monitoring and treatment of hypertension. However not all of the automated devices available in the market are validated in accordance with the existing protocols for this purpose. The purpose of this study was to confirm the validation of the automatic measuring device of the BP, OMRON® M6 Comfort, according to the “European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults”. Methodology – The study involved 33 subjects, in each one of them, 9 sequential measurements of BP were performed, in the left arm, with the aneroid sphygmomanometer alternating with the automatic device. Afterwards, the differences on the values obtained by the different devices were evaluated, for systolic blood pressure (SBP) and diastolic (DBP), and these differences were then classified into three levels (≤ 5, ≤ 10 or ≤ 15 mmHg). The number of differences at each level was compared to the number required by the protocol (phase 1.1). For each subject the number of differences with values ≤ 5 mmHg was also determined. At least 24 of the 33 subjects should have 2 or 3 differences with values ≤ 5 mmHg and a maximum of 3 of the 33 subjects may have all differences with values > 5 mmHg (phase 1.2). Results – The device OMRON M6 Comfort ® was approved in phases 1.1 and 1.2 for SBP and DBP. The average difference between measurements of BP, as determined by automatic and manual devices, was -0.82 ± 5.62 mmHg for SBP and 2.14 ± 5.15 mmHg for DBP. Conclusion – The device OMRON M6 Comfort® is valid for measuring BP in adults, according to the ESH International Protocol of 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Na presente dissertação, o trabalho desenvolvido teve como objetivo, a avaliação de alguns parâmetros de durabilidade de argamassas com incorporação de catalisador exausto de FCC (do inglês “Fluid Catalytic Cracking”) para serem utilizadas na reparação de estruturas de betão. O catalisador exausto de FCC é um resíduo da indústria petrolífera e o utilizado neste estudo é proveniente da refinaria da Petrogal, S.A. em Sines. A presente investigação baseou-se na preparação, e avaliação de propriedades, de duas séries distintas de argamassas: a série que se denominou “RAS” e a série que se denominou “Durabilidade”, nas quais se substituiu, parcialmente entre 5, 10 e 15%, em massa de cimento por resíduo exausto de FCC. As argamassas de ambas as séries diferenciam-se entre si, sobretudo, pela utilização de areia reativa nas argamassas da série RAS e de areia inerte no caso das argamassas da série durabilidade. Nas argamassas estudadas foram realizados ensaios no estado fresco e ensaios no estado endurecido. Os ensaios no estado fresco incluíram a determinação da consistência por espalhamento, da massa volúmica e do teor de ar. Nos ensaios no estado endurecido foram avaliadas, no caso das argamassas da série RAS a extensão da reação àlcalis-sílica e no caso das argamassas da série Durabilidade as resistências mecânicas - à flexão e à compressão, a resistência à carbonatação acelerada, o módulo de elasticidade à compressão, a absorção capilar, a permeabilidade ao oxigénio, a difusão de cloretos em regime não estacionário. O trabalho desenvolvido nesta dissertação demonstrou que a incorporação de catalisador exausto de FCC, em argamassas à base de cimento, minimiza o efeito de expansão das reações álcalis-sílica, bem como contribui para reduzir a absorção capilar e coeficiente de difusão de cloretos. No entanto, este resíduo quando incorporados em argamassas contribui para a diminuição da resistência à carbonatação acelerada e para o aumento da permeabilidade ao oxigénio.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Proteção Contra Radiações

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Fisioterapia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A replicate evaluation of increased micronucleus (MN) frequencies in peripheral lymphocytes of workers occupationally exposed to formaldehyde (FA) was undertaken to verify the observed effect and to determine scoring variability. May–Grünwald–Giemsa-stained slides were obtained from a previously performed cytokinesis-block micronucleus test (CBMNT) with 56 workers in anatomy and pathology laboratories and 85 controls. The first evaluation by one scorer (scorer 1) had led to a highly significant difference between workers and controls (3.96 vs 0.81 MN per 1000 cells). The slides were coded before re-evaluation and the code was broken after the complete re-evaluation of the study. A total of 1000 binucleated cells (BNC) were analysed per subject and the frequency of MN (in ‰) was determined. Slides were distributed equally and randomly between two scorers, so that the scorers had no knowledge of the exposure status. Scorer 2 (32 exposed, 36 controls) measured increased MN frequencies in exposed workers (9.88 vs 6.81). Statistical analysis with the two-sample Wilcoxon test indicated that this difference was not significant (p = 0.17). Scorer 3 (20 exposed, 46 controls) obtained a similar result, but slightly higher values for the comparison of exposed and controls (19.0 vs 12.89; p = 0.089). Combining the results of the two scorers (13.38 vs 10.22), a significant difference between exposed and controls (p = 0.028) was obtained when the stratified Wilcoxon test with the scorers as strata was applied. Interestingly, the re-evaluation of the slides led to clearly higher MN frequencies for exposed and controls compared with the first evaluation. Bland–Altman plots indicated that the agreement between the measurements of the different scorers was very poor, as shown by mean differences of 5.9 between scorer 1 and scorer 2 and 13.0 between scorer 1 and scorer 3. Calculation of the intra-class correlation coefficient (ICC) revealed that all scorer comparisons in this study were far from acceptable for the reliability of this assay. Possible implications for the use of the CBMNT in human biomonitoring studies are discussed.