42 resultados para DOSE VERIFICATION

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo tem por objectivos determinar a Dose Glandular Média - Mean Glandular Dose (MGD) - em 3 sistemas de Mamografia e comparar os valores obtidos com os referenciais internacionais. O estudo foi realizado num sistema analógico de Écran-Película (EP) e em dois sistemas de imagem digital (CR e DR). Foi efectuado o cálculo da Entrance Surface Air Kerma (ESAK) e da MGD em três equipamentos a partir de uma amostra de dados referentes a 30 mulheres assintomáticas, com idades compreendidas entre os 40 e 64 anos. Em cada equipamento objecto de análise, foram recolhidos os dados referentes a 10 mulheres. Foram consideradas as projecções crânio-caudal (CC) e oblíqua médio-lateral (MLO). A análise de resultados revelou que o valor de MGD varia quando se compara os três sistemas. Nas incidências CC os valores de MGD obtidos foram de 1,54 mGy (EP), 1,78 mGy (CR) e 0,82 mGy (DR). Nas incidências MLO o valor de MGD foi de 1,53 mGy no sistema EP, de 1,78 mGy no CR e 0,87 mGy no sistema DR. Constata-se que o valor de MGD na incidência de CC é inferior ao valor de MGD na incidência MLO, excepto para o sistema EP. Verifica-se também que o sistema EP apresenta maior variabilidade nos dados de MGD comparativamente com os restantes sistemas. O sistema DR é o que apresenta a menor variabilidade de valores MGD e também valores de MGD mais baixos. Comparando os resultados deste estudo com as referências internacionais, verifica-se que a MGD se encontra abaixo do limite de 2 mGy recomendado. ABSTRACT - This study aims to estimate the Mean Glandular Dose (MGD) associated with three different mammographic systems and compare the results with recommended international reference values. The systems included in the study included a conventional Screen-Film (SF) system and two digital mammography systems (CR and DR). Entrance Surface Air Kerma (ESAK) and MGD associated with each equipment were calculated. A sample of 30 healthy women (age ranging from 40 to 64 years old) undertaking screening mammography was considered in this study. The mammographic exam includes two projections, cranio-caudal (CC) and medio-lateral oblique (MLO). The MGD results obtained for CC projection were 1,54 mGy (SF), 1,78 mGy (CR) and 0,82 mGy (DR). MGD values for the MLO projection were 1,53 mGy (SF), 1,78 mGy (CR) and 0,87 mGy (DR). Results show that MGD value is slightly lower in the CC projection than in MLO, except for the SF system (1,54 mGy; 1,53 mGy). In addition the MGD for the SF system varied more than that associated with the digital systems. The DR system allows a narrow variation of MGD values and also lower MGD values. Comparing this study results with the international references we concluded that MGD values are below the 2 mGy recommended value for the three systems evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção Contra Radiações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção contra Radiações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os erros de medicação são um problema de saúde pública com uma repercussão económica importante, afectando a qualidade de vida dos utentes e os custos em saúde. Ao nível da farmácia hospitalar, “que tem como principal função a dispensa dos medicamentos aos doentes de acordo com a prescrição médica, nas quantidades e especificações solicitadas, de forma segura e no prazo requerido, promovendo o uso seguro e racional do medicamento,” o erro de distribuição é definido como a discrepância entre a ordem prescrita pelo médico e o atendimento dessa ordem, podendo gerar oportunidades de erros de administração. Os erros classificam-se em função da etapa do circuito do medicamento em que ocorrem: prescrição, distribuição e administração. A distribuição de medicamentos em sistema de dose unitária (DMDU) está descrita como imperativo para aumentar a segurança no circuito do medicamento, prevendo uma distribuição diária de medicamentos, em dose individual unitária, para um período de 24 horas. Sempre que possível, a DMDU deverá apoiar-se em equipamentos semi-automáticos, para redução dos erros. Sendo a qualidade e segurança uma preocupação crescente e uma prioridade dos sistemas de saúde, os profissionais de saúde devem intervir activamente na melhoria dos sistemas de utilização dos medicamentos para garantir a segurança do doente. Consequentemente, vários estudos têm sido desenvolvidos para verificar os tipos de erros mais frequentes em farmácia hospitalar. Objectivo do estudo: identificar os principais erros de distribuição em dose unitária descritos na literatura nos últimos 5 anos e as suas causas, através de uma revisão sistemática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: O cancro retal continua a ser um dos principais problemas de saúde a nível mundial, sendo a toxicidade gastro-intestinal e génito-urinária os efeitos tardios da radioterapia mais reportados. A utilização da Belly-Board para minimizar essa toxicidade, reduzindo o volume de bexiga e intestino delgado irradiados é recomendada. No entanto, o protocolo mais adequado para o volume vesical nestes doentes é ainda tema de controvérsia. Objetivo: Avaliar a influência do volume vesical na dose recebida na bexiga e no PTV, em doentes com tumor de reto, posicionados em decúbito ventral, com belly-board. Materiais e Métodos: 38 doentes com tumor de reto tratados no CHBM, agrupados em dois grupos: o 1º grupo, com 19 doentes que realizaram tratamento com bexiga cheia e o 2º grupo, com 19 doentes que realizaram tratamento com bexiga vazia. Os dados foram obtidos através dos HDV’s e foram comparadas as doses máximas no PTV e a percentagem de volume de bexiga que recebe 50Gy. Foi utilizado o teste estatístico U-Mann Whitney com um nível de significância de 0,05. A hipótese de pesquisa deste estudo propõe que os dois grupos diferem significativamente entre si e a hipótese nula propõe que os dois grupos não diferem significativamente entre si, para ambas as variáveis. Resultados: Não se observaram diferenças estatisticamente significativas entre os grupos no que diz respeito à dose máxima no PTV. No que se refere à percentagem de volume de bexiga que recebe 50Gy verificaram-se diferenças estatisticamente significativas, tendo o grupo de doentes que realizaram tratamento com bexiga cheia apresentado valores mais baixos. Conclusões: Este estudo demonstrou o benefício da utilização do protocolo de bexiga cheia em doentes com tumor de reto tratados com belly-board, na diminuição da percentagem de volume de bexiga que recebe 50Gy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Terapia com Radiações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – As funções a desempenhar pelos técnicos de radiologia (TR) envolvem exposição ocupacional às radiações ionizantes, podendo acarretar potenciais efeitos biológicos. Metodologia – De modo a avaliar a dose efetiva recebida pelo TR nos diferentes métodos de estudo radiológico em que este trabalha, procedeu-se à realização de um estudo exploratório-descritivo. Efetuaram-se medições com dosímetros termoluminescentes em cinco valências radiológicas e foram aplicados questionários aos TR para determinar o tempo total de trabalho, bem como as medidas gerais de proteção radiológica utilizadas durante o período de medições. Resultados – Verificou-se que as doses efetivas, calculadas por hora, foram mais elevadas na valência de radiologia de intervenção, com os dados obtidos sobre a proteção plumbínea, sendo que a valência com menor dose efetiva calculada por hora foi a de mamografia, que apresentou um valor de medição igual a zero. Conclusões – Com o presente estudo conclui-se que existem diferenças de dose efetiva recebida de acordo com a função desempenhada pelo TR. Pela extrapolação dos valores calculados para doses efetivas anuais, verificou-se que os valores correspondentes a cada valência se encontram muito abaixo do limite anual legal de 20mSv.