8 resultados para Benign Hypercalcemia
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
This paper concerns the study of biocides application in old timber structures of maritime pine (Pinus pinaster Ail.), previously impregnated with other products. A method was developed in laboratory to determine in situ the penetration depth of a product applied superficially. As initial treatment, three traditional products for sawn timber for buildings were used and, for new treatments, two newer, more environmentally benign products were used. Their ability to penetrate the pre-treated surfaces was evaluated after 1, 2 and 3 applications at 24 hours intervals and the results obtained are presented. Finally, the applicability of the developed test to the in-situ evaluation of timber structures is also discussed.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Ressonância Magnética
Resumo:
Introdução – A técnica de Difusão por Ressonância Magnética (RM), ao avaliar o movimento das moléculas de água nos tecidos, permite inferir sobre a arquitetura dos mesmos, em particular relativamente à celularidade, volume celular e permeabilidade das membranas. O Coeficiente de Difusão Aparente (ADC) é um parâmetro quantificável da imagem ponderada em difusão (DWI). A sua análise poderá fornecer informação clínica adicional sobre estas lesões, sobretudo em relação à sua caracterização histológica. Objetivos – Caracterizar e diferenciar tipos e alguns subtipos de lesões mamárias através da análise do ADC. Metodologia – 20 Mulheres com 23 lesões mamárias foram submetidas a RM mamária: 3 lesões benignas (3 Fibroadenomas-FA) e 20 malignas (16 Carcinomas Ductais Invasivos-CDI, 2 Carcinomas Ductais In Situ-CDIS e 2 Carcinomas Invasivos Lobulares-CLI). Num equipamento 1.5T aplicou-se uma sequência de Difusão (b=0,50,250,500,750,1000 s/mm2). Obteve-se o ADC através do ajuste exponencial da intensidade de sinal das lesões em função do valor de b, fazendo-se corresponder os valores de ADC à respetiva caracterização histológica e posterior comparação com a literatura. Resultados e Discussão – As lesões malignas apresentaram ADCs significativamente (p=0,014) inferiores [(0,94±0,22)x10-3 mm2/s] aos das benignas [(1,43±0,25)x10-3 mm2/s]. A justificação pode residir no aumento da celularidade e consequente restrição da Difusão que se observa nas lesões malignas. Os CDI apresentaram ADCs baixos [(0,88±0,17)x10-3 mm2/s], enquanto que os CDIS apresentaram ADCs mais elevados [(1,33±0,29)x10-3 mm2/s]. Estes resultados estão de acordo com o facto dos CDIS estarem limitados aos ductos mamários, mantendo-se menos alterada a estrutura do tecido adjacente e resultando numa menor restrição à difusão que nos CDI. Verificaram-se diferenças significativas entre FA e CDI (p=0,010) e entre CDI e CDIS (p=0,049). Conclusões – O ADC possibilita a diferenciação entre lesões mamárias benignas e malignas, bem como entre alguns tipos histológicos. O desenvolvimento deste conceito pode representar um avanço no papel da RM na avaliação destas neoplasias. ABSTRACT - Introduction – The Magnetic Resonance (MR) diffusion technique measures the movement of water molecules in tissues. Therefore, it provides useful information about tissue architecture, specially regarding tissue cellularity, cell volume and membrane permeability. The quantification of diffusion weighted imaging (DWI) data is done by measuring the so-called. Apparent Diffusion Coefficient (ADC). This parameter provides additional clinical information about breast lesions, and potentially allows for in-vivo histological characterization. Purpose – To characterize and differentiate breast lesions through ADC analysis. Methodology – The study comprised 20 women, with 23 breast lesions: 3 benign lesions - 3 Fibroadenomas (FA); and 20 malignant - 16 Invasive Ductal Carcinomas (CDI), 2 Ductal Carcinomas In Situ (CDIS), 2 Invasive Lobular Carcinoma (CLI). On a 1.5T equipment a diffusion-weighted sequence with 6 b-values (b=0,50,250,500,750,1000 s/mm2) was used to examine the patients. ADC was obtained by fitting an exponential to data of lesion signal intensity vs. b values. A correspondence of ADC values to histological lesion characterization was done and finally, the results were comparison with the literature. Results and Discussion – Malignant lesions showed inferior ADCs significantly (p=0.014) lower ((0.94±0.22)x10-3 mm2/s) than the benign lesions ((1.43±0.25)x10-3 mm2/s). This may be associated to increasead cellularity in malignant lesions, which result in higher tissue restriction to diffusion. CDI showed low ADC values ((0.88±0.17)x10-3 mm2/s), while the CDIS showed higher ADCs ((1.33±0.29)x10-3 mm2/s). These results agree with the fact that CDIS are limited to mammary ducts, maintaining a less altered neighboring tissue structure, which results in a lower restriction to diffusion than observed in CDI. Significant differences between FA and CDI (p=0.010) and between CDI and CDIS (p=0.049) were observed. Conclusion – The ADC parameter is able to differentiate between malignant and benign breast lesions, as well as between some histological types.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.
Resumo:
The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.
Resumo:
Os sistemas Computer-Aided Diagnosis (CAD) auxiliam a deteção e diferenciação de lesões benignas e malignas, aumentando a performance no diagnóstico do cancro da mama. As lesões da mama estão fortemente correlacionadas com a forma do contorno: lesões benignas apresentam contornos regulares, enquanto as lesões malignas tendem a apresentar contornos irregulares. Desta forma, a utilização de medidas quantitativas, como a dimensão fractal (DF), pode ajudar na caracterização dos contornos regulares ou irregulares de uma lesão. O principal objetivo deste estudo é verificar se a utilização concomitante de 2 (ou mais) medidas de DF – uma tradicionalmente utilizada, a qual foi designada por “DF de contorno”; outra proposta por nós, designada por “DF de área” – e ainda 3 medidas obtidas a partir destas, por operações de dilatação/erosão e por normalização de uma das medidas anteriores, melhoram a capacidade de caracterização de acordo com a escala BIRADS (Breast Imaging Reporting and Data System) e o tipo de lesão. As medidas de DF (DF contorno e DF área) foram calculadas através da aplicação do método box-counting, diretamente em imagens de lesões segmentadas e após a aplicação de um algoritmo de dilatação/erosão. A última medida baseia-se na diferença normalizada entre as duas medidas DF de área antes e após a aplicação do algoritmo de dilatação/erosão. Os resultados demonstram que a medida DF de contorno é uma ferramenta útil na diferenciação de lesões, de acordo com a escala BIRADS e o tipo de lesão; no entanto, em algumas situações, ocorrem alguns erros. O uso combinado desta medida com as quatro medidas propostas pode melhorar a classificação das lesões.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Terapia com Radiações
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Ressonância Magnética