7 resultados para Below-Knee Amputee

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: to investigate the relationship between knee muscle strength, balance and functional independence within the first month after stroke. Relevance: cerebral vascular disease is one of the main causes of morbidity, disability and mortality in developed countries. Problems with movement control are frequent after stroke. Lower limb weakness and impaired balance are common problems that are related with the risk of falls and are likely to interfere with the ability to perform daily life activities. Physiotherapy intervention usually starts early after stroke and addresses impairments related to movement and posture in order to improve motor recovery and restore function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – Os componentes protésicos têm um papel fundamental na eficiência energética da marcha dos indivíduos amputados. Esta é uma área de conhecimento ainda em desenvolvimento, onde a investigação desempenha um papel central. Objectivos – Comparar e analisar o efeito de dois joelhos protésicos, 3R34, monocêntrico modular, de fricção constante, com auxiliar de extensão incorporado (A) e 3R92, monocêntrico modular, com travão de fricção e controlo pneumático da fase de balanço (B) no consumo energético e eficiência da marcha. Metodologia – Um indivíduo do sexo masculino de 27 anos, com amputação transfemural longa, foi sujeito a um protocolo submáximo de avaliação da resposta ao exercício em passadeira rolante (H/P/Cosmos(R) Mercury), através de um sistema de análise de gases breath‑by‑breath (Cosmed Quark PFT Ergo). Foi efetuado o mesmo protocolo com intervalo de dois dias, primeiro utilizando o joelho A e depois o B. As variáveis analisadas foram o consumo de O2 (VO2), o equivalente metabólico (MET) e a eficiência energética da marcha (Quociente de VO2 esperado de um individuo saudável e o VO2 do individuo em estudo). O esforço percecionado foi medido com a escala RPE de Borg. Resultados – O consumo energético com o joelho A (24,2 ml O2/kg/min; 6,9 MET) foi inferior ao obtido com o joelho B (28,68 ml O2/kg/min; 8,2 MET). A eficiência energética da marcha foi mais elevada para o joelho A (43%) do que para o joelho B (39%). Conclusão – A utilização do joelho A na prótese do indivíduo em estudo resulta numa marcha de menor consumo energético e maior eficiência. No entanto, este valor poderá estar influenciado pelo curto período de adaptação ao joelho B, sendo necessários mais estudos para confirmar os resultados do estudo e a influência deste fator. ABSTRACT - Background – Prosthetic components have a crucial role in the energy efficiency of amputee’s gait. This is an area of knowledge still in development, where research plays a central role. Objective – The purpose of this case study is to compare the impact in energy consumption of two prosthetic knees, titanium single‑axis constant friction knee joint with internal extension assist, 3R34 (A) and a single‑axis pneumatic swing phase control, 3R92 (B). Methodology – The participant was a transtibial amputee, male, with 27 years old, with no other clinical or functional impairments. To measure the energy expenditure a submaximal treadmill (H/P/Cosmos(R) Mercury) exercise stress test combined with a breath‑by‑breath analysis system (Cosmed Quark PFT Ergo) was used. The same test was applied to both knees, separated by two days. The analyzed variables were O2 consumption (VO2), metabolic equivalent (MET) and gait efficiency (VO2 ratio expected from a healthy individual and the studied individual). A rate of perceived exertion (Borg’s Scale) was used. Results – The results were favorable to knee A (24.2 ml O2/kg/min; 6.9 MET, 43% efficiency) compared with knee B (28.68 ml O2/kg/min; 8.2 MET, 39% efficiency). Conclusion – In this case, a less energy consumption gait corresponds to the prosthesis with knee A. These values may be influenced by the short adaptation period with knee B, so it’s necessary to perform more studies to confirm the previous results and to understand the truly impact of correct adaptation factor to the best prosthetics components for different patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ballet gestures are highly non-anatomical and physiological, leading to compensatory behaviors. The knee joint is most affected by this behavior, leading to an increase risk of injury. Our purpose is to describe the knee angular displacement in amateur dancers, during a demi-plié exercise, with emphasis on valgus mechanisms frequency. Methods: 192 demi-pliés collected in six amateur female dancers (mean age = 15.33 ± 1.37 years), were analyzed regarding sagittal and frontal plane angular displacement, with an electrogoniometer connected to a signal acquisition unit at 1000 Hz. Results: all subjects presented valgus peaks along the trials, despite the global varus tendency of the knee frontal plane behavior. A significant positive correlation between the frequency of valgus and practice time was noted. Discussion: A variable angular frontal displacement was observed, with some trials comprehending a high incidence of valgus peaks along the ascending or descending phase of the demi-plié exercise. Conclusion: the frontal knee angle behavior is variable. It may present fast peaks of valgus or an initial trend of varus/valgus that is different from the global varus trend. The analysis of the activity should be considered in the training. The practice time may be related to the observed behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução – O efeito de êmbolo é um dos principais problemas relacionados com a eficácia de uma prótese. Uma diminuição do mesmo pode levar a uma marcha mais natural através do aumento da propriocetividade. Objetivos – Verificar se existe diferença de valores do efeito de êmbolo entre vários sistemas de suspensão para próteses transtibiais com a utilização de Liners e testar a aplicação de testes de imagiologia na análise da melhor solução protésica para um determinado indivíduo. Metodologia – Foi obtida uma radiografia da prótese em carga na posição ortostática, mantendo o peso do indivíduo igualmente distribuído pelos dois pés. Seguidamente foi realizada outra radiografia no plano sagital com o joelho com 30° de flexão, com a prótese suspensa e um peso de 5kg aplicado na extremidade distal da mesma durante 30 seg. Através destes dois exames efetuaram-se as medições do êmbolo para cada tipo de sistema de suspensão. Resultados – Dos quatro sistemas estudados apenas três apresentam valores de êmbolo, visto que um dos sistemas não criou suspensão suficiente para suportar o peso colocado na extremidade distal da prótese. Através das medições realizadas nos exames imagiológicos dos três sistemas pudemos encontrar variações de efeito de êmbolo que vão dos 47,91mm aos 72,55mm. Conclusão – Através da realização do estudo imagiológico verificaram-se diferenças a nível do efeito de êmbolo nos vários sistemas de suspensão, provando que esta é uma ferramenta viável na avaliação do mesmo. Também através da análise dos resultados ficou notório que o sistema de suspensão Vacuum Assisted Suspention System (VASS) é o que apresenta menos êmbolo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The harmony between the stump and the prosthesis is critical to allow it to fulfill its function enabling an efficient gait. A well fitted socket, with an efficient and comfortable suspension, allows the amputee to continue their daily living activities, maintaining the stump functional, making this correlation between socket and suspension very important in the functionality of the prosthesis, mobility and overall satisfaction with the device. Of our knowledge, the quantitative correlation between all of these factors as not yet been assessed. Aim of study: Verify and confirm the process of decision-making for four different trans-tibial prostheses with suspension systems: Hypobaric(A), PIN(B), Classic Suction(C) and Vacuum Active –VASS(D) according data provided by gait efficiency (mlO2/kg/m) imagiology (pistonning) and amputee perception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de Estágio submetidoà Escola Superior de Teatro e Cinemapara cumprimento dos requisitos necessários à obtenção do grau de Mestre em Artes Performativas- especialização em Teatro-Música

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction - The harmony between the stump and the prosthesis is critical to allow it to fulfill its function enabling an efficient gait. A well fitted socket, with an efficient and comfortable suspension, allows the amputee to continue their daily living activities, maintaining the stump functional, making this correlation between socket and suspension very important in the functionality of the prosthesis, mobility and overall satisfaction with the device. Of our knowledge, the quantitative correlation between all of these factors as not yet been assessed. The objective of this study is to verify and confirm the process of decision-making for four different trans-tibial prostheses with suspension systems: Hypobaric(A), PIN(B), Classic Suction(C) and Vacuum Active –VASS(D) according data provided by gait efficiency (mlO2/kg/m) imagiology (pistonning) and amputee perception.