7 resultados para Android,Peer to Peer,Wifi,Mesh Network

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rapidly increasing computing power, available storage and communication capabilities of mobile devices makes it possible to start processing and storing data locally, rather than offloading it to remote servers; allowing scenarios of mobile clouds without infrastructure dependency. We can now aim at connecting neighboring mobile devices, creating a local mobile cloud that provides storage and computing services on local generated data. In this paper, we describe an early overview of a distributed mobile system that allows accessing and processing of data distributed across mobile devices without an external communication infrastructure. Copyright © 2015 ICST.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Resolução do Conselho de Ministros n.º 120/2008, de 30 de Julho, definiu como prioridade estratégica para o País, no sector das comunicações electrónicas, a promoção do investimento em redes de nova geração. Com o objectivo de dar execução às orientações estratégicas estabelecidas, o Decreto -Lei n.º 123/2009, de 21 de Maio, veio estabelecer um conjunto de obrigações aplicáveis ao Estado, às Regiões Autónomas, às autarquias locais, empresas públicas, concessionárias e, genericamente, às entidades que detenham infra-estruturas que se integrem em domínio público, de forma a garantir a todas empresas de comunicações electrónicas, o acesso às infra-estruturas aptas ao alojamento de redes de comunicações electrónicas. Em Portugal, o caminho a ser traçado até as redes de nova geração passa pela, abertura eficaz e não discriminatória de todas as condutas e outras infra-estruturas aptas ao alojamento de redes de comunicações electrónicas, elaboração de regras técnicas aplicáveis às infra-estruturas de telecomunicações em loteamentos, urbanizações e conjuntos de edifícios, adopção de soluções que eliminem ou atenuem as barreiras verticais à instalação de fibra óptica e que evitem a monopolização do acesso aos edifícios pelo primeiro operador. Neste âmbito, excluem-se, pela sua especial natureza e fins a que estão afectas, as redes privativas dos órgãos políticos de soberania, do Ministério da Defesa Nacional, das forças e serviços de segurança, de emergência e de protecção civil. Assim, este trabalho visa apresentar procedimentos aplicáveis às infra-estruturas de telecomunicações para elaboração de um cadastro de todas as infra-estruturas, públicas e privadas, aptas ao alojamento de redes de comunicações electrónicas, e propor instruções técnicas para as condições e direitos de acesso, construção e intervenção sobre estas infra-estruturas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0%, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0%, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCEs) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35 degrees C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 min. In the hardened state, silica fumes increased not only the grout's porosity but also the grout's compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 d and beyond. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relatório de estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Vias de Comunicação e Transportes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações