41 resultados para stat.AP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present a possible design for a passive RFID tag antenna on paper substrate to be integrated into bottle labels. Considering the application scenario, we verified and determined the permittivity and dissipation factor of the materials in order to simulate all the possible sources that would influence the antenna performance. The measured results reported a maximum reading range of 1.45 m even though the efficiency obtained with the antenna integrated into the bottle was only of 3%. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No presente artigo de revisão quisemos explorar os papéis maternos e paternos no estabelecimento da vinculação e na qualidade da interação entre pais (pais e mães) e filhos nos primeiros dois anos de vida. Vários estudos recorrendo à Situação Estranha indicam que a vinculação segura é mais frequente em díades mãe-filho do que em díades pai-filho, e que as mães em média são mais sensíveis do que os pais. No entanto, a diversidade de estudos, metodologias e resultados permitem-nos reinterpretar o papel paterno. Adicionalmente, as medidas de avaliação da sensibilidade foram, na maioria dos casos, aferidas em estudos da relação mãe-filho(a) e não sabemos se integram a diversidade de comportamentos da relação pai-filho(a). Importa compreender e discutir as diferenças da vinculação com a mãe e com o pai no quadro mais amplo das relações da família.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cafeína é o estimulante mais conhecido mundialmente, tendo um efeito viciante que implica a determinação de uma relação risco-benefício. Os seus principais efeitos cardiovasculares são ao nível da pressão arterial (PA), frequência cardíaca (FC) e catecolaminas plasmáticas. Objetivos do estudo - Verificar as variações nos parâmetros eletrocardiográficos, FC, PA e velocidade de onda de pulso arterial (VOP) nos estudantes da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) após consumo de café.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: University students are frequently exposed to events that can cause stress and anxiety, producing elevated cardiovascular responses. Repeated exposure to academic stress has implications to students’ success and well-being and may contribute to the development of long-term health problems. Objective: To identify stress levels and coping strategies in university students and assess the impact of stress experience in heart rate variability (HRV). Methods: 17 university students, 19-23 years, completed the University Students Stress Inventory, the Depression Anxiety Stress Scales and the Ways of Coping Questionnaire. Two 24h-Holter recordings were performed, on academic activity days, including one of them an exam situation. Results: Students tend to present moderate stress levels, and prefer problem-focused coping strategies in order to manage stress. Exam situations are perceived as significant stressors. Although we found no significant differences in HRV (SDNN), between days with and without an exam, we registered a lower SDNN score and a variation in heart rate (HR) related to exam situation (maximum HR peak at 10 minutes before the exam, and total HR recovery 20 minutes after the exam), reflecting sympathetic activation due to stress. Conclusions: These results suggest that academic events, especially those related to exam situations, are the cause of stress in university students, with implications at cardiovascular level, underlying the importance of interventions that help these students improve their coping skills and optimize stress management, in order to improve academic achievement and promote well-being and quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projeto realizado para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde