34 resultados para questionnaire validation procedures
Resumo:
Mestrado em Segurança e Higiene do Trabalho.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção do grau de mestre em Ciências da Educação - Especialidade Educação Especial
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
GimC/Prefoldin is a hetero-oligomeric complex involved in cytoskeleton biogenesis. In order to identify by two-hybrid system targets that directly interact with Gims and support the stress phenotypes, this work aimed the functional validation of all Gims in saccharomyces cerevisiae.
Resumo:
Mestrado em Intervenção Sócio-Organizacional na Saúde. Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Educação Artística, na Especialização de Artes Plásticas na Educação
Resumo:
A investigação desenvolvida no âmbito do projeto Estratégias de Intervenção socioeducativa em contextos sociais complexos enquadra-se na avaliação das políticas sociais e educativas, em particular no que diz respeito à segurança escolar em contextos marcados pela diversidade e complexidade social e cultural. O processo de avaliação centrou-se na análise das estratégias de intervenção socioeducativa relativas ao problema da violência na escola, desenvolvidas em três escolas de um concelho da Área Metropolitana de Lisboa. Partindo do pressuposto que a violência na escola é um fenómeno multideterminado e multifacetado, a pesquisa centrou-se numa abordagem que enquadra as esferas de intervenção/ação das instituições formais e dos agentes sociais enquanto mecanismos que estruturam e regulam as concepções e práticas de violência na escola. A recolha e sistematização de informação centrou-se, por um lado, nas estratégias de intervenção que têm vindo a ser desenvolvidas localmente pelas escolas, e, por outro, nas perspetivas dos diferentes intervenientes, considerando-se os alunos, osprofessores, as direções escolares e representantes das entidades e instituições locais. Metodologicamente, privilegiou-se o cruzamento de métodos de carácter extensivo e intensivo, combinando técnicas como a Observação Direta, a realização de Entrevistas, de Grupos Focais, de Questionários, e ainda, a Análise de Redes e a Análise Documental. Numa fase posterior, os diversos intervenientes participaram na discussão e análise dos resultados previamente recolhidos, e na validação conjunta de uma metodologia de intervenção que define um conjunto de estratégias gerais de combate às situações de violência na escola e nos territórios educativos. Esta metodologia é o principal produto do projeto e resulta de um processo de avaliação dinâmico e participado. A contribuição que se apresenta no VI Encontro do CIED ocupa-se dos procedimentos de avaliação desenvolvidos no âmbito deste projeto.
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality perception for chest X-ray images. Methods - Bandura's theory was used to guide scale development. A review of the literature was undertaken to identify items/factors which could be used to evaluate image quality using a perceptual approach. A draft scale was then created (22 items) and presented to a focus group (student and qualified radiographers). Within the focus group the draft scale was discussed and modified. A series of seven postero-anterior chest images were generated using a phantom with a range of image qualities. Image quality perception was confirmed for the seven images using signal-to-noise ratio (SNR 17.2–36.5). Participants (student and qualified radiographers and radiology trainees) were then invited to independently score each of the seven images using the draft image quality perception scale. Cronbach alpha was used to test interval reliability. Results - Fifty three participants used the scale to grade image quality perception on each of the seven images. Aggregated mean scale score increased with increasing SNR from 42.1 to 87.7 (r = 0.98, P < 0.001). For each of the 22 individual scale items there was clear differentiation of low, mid and high quality images. A Cronbach alpha coefficient of >0.7 was obtained across each of the seven images. Conclusion - This study represents the first development of a chest image quality perception scale based on Bandura's theory. There was excellent correlation between the image quality perception scores derived using the scale and the SNR. Further research will involve a more detailed item and factor analysis.
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões
Resumo:
Mestrado em Fisioterapia
Resumo:
Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semiautomated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developingCADto be predicted will be presented. A64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
Resumo:
Relatório Final de Estágio apresentado à Escola Superior de Dança, com vista à obtenção do grau de Mestre em Ensino de Dança.
Resumo:
Introdução e objetivos: A síncope recorrente tem um impacto significativo na qualidade de vida. O desenvolvimento de escalas de medida de fácil aplicabilidade clínica para avaliar este impacto é fundamental. O objetivo do presente estudo é a validação preliminar da escala Impact of Syncope on Quality of Life, para a população portuguesa. Métodos: O instrumento foi submetido a um processo de tradução, validação, adequação cultural e cognitive debriefing. Participaram 39 doentes com história de síncopes recorrentes (>1 ano de evolução), submetidos a teste de inclinação em mesa basculante (teste de tilt), que constitui uma amostra de conveniência, com idade de 52,1±16,4 anos (21-83; 43,5% do sexo masculino), a maioria com uma situação profissional ativa (n=18) ou reformados (n=13). A versão portuguesa resultou numa versão semelhante unidimensional à original com 12 itens agregados num único somatório, tendo passado por validação estatística, com avaliação da fidelidade, validade e estabilidade no tempo. Resultados: Em relação à fidelidade, a consistência interna da escala é de 0,9. Avaliámos a validade convergente, tendo obtido resultados estatisticamente significativos (p<0,01). Avaliámos a validade divergente tendo obtido resultados estatisticamente significativos. Relativamente à estabilidade no tempo foi efetuado um teste-reteste do instrumento aos seis meses após o teste de inclinação com 22 doentes desta amostra não submetidos a intervenção clínica, que não mostrou alterações estatisticamente significativas da qualidade de vida. Conclusões: Os resultados obtidos indicam a pertinência da utilização deste instrumento em contexto português na avaliação da qualidade de vida de doentes com síncope recorrente.
Resumo:
The DatScanTM and its Semiquantification (SQ) can provide advantages in the diagnosis of Parkinsonian Syndromes (PS). To improve the SQ is recommended the creation of adapted database (DB) with reference values for the Nuclear Medicine Departments. Previously to this work was created a adapted database (DBRV) to Nuclear Medicine Department's protocol and population of Infanta Cristina's Hospital located in Badajoz, for patients between the ages of 60 and 75, and reference values of the SQ were calculated. Aim: To evaluate the discrimination capacity of a department's adapted DB reference's values of healthy controls for DatScanTM.