24 resultados para manual plate
Resumo:
Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?
Resumo:
A aquisição de competências ao nível da compreensão na leitura apresenta-se, cada vez mais, como o caminho para chegar ao conhecimento. O tipo de texto que se assume como o meio privilegiado de acesso ao conhecimento é o texto expositivo. Como tal, é importante que os textos a que os alunos têm acesso diariamente na sala de aula (nomeadamente, os textos dos manuais) sejam adequados ao desenvolvimento dessas competências. Neste estudo,analisaram-se os textos expositivos do manual de Estudo do Meio do 4.º ano mais adotado em Portugal no ano letivo 2010/2011. Em concreto, apurou-se a percentagem de textos expositivos existentes no manual, analisou-se a sua estrutura (Meyer, 1985), o tipo de questões que os acompanham, bem como as relações entre as perguntas e as respostas (Raphael, 1986, cit. em Giasson, 2000). O manual foi ainda analisado à luz do que é preconizado pelos documentos oficiais do Ministério da Educação.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
This paper presents a computational tool (PHEx) developed in Excel VBA for solving sizing and rating design problems involving Chevron type plate heat exchangers (PHE) with 1-pass-1-pass configuration. The rating methodology procedure used in the program is outlined, and a case study is presented with the purpose to show how the program can be used to develop sensitivity analysis to several dimensional parameters of PHE and to observe their effect on transferred heat and pressure drop.
Resumo:
With very few exceptions, M > 4 tectonic earthquakes in the Azores show normal fault solution and occur away from the islands. Exceptionally, the 1998 shock was pure strike-slip and occurred within the northern edge of the Pico-Faial Ridge. Fault plane solutions show two possible planes of rupture striking ENE-WSW (dextral) and NNW-SSE (sinistral). The former has not been recognised in the Azores, but is parallel to the transform direction related to the relative motion between the Eurasia and Nubia plates. Therefore, the main question we address in the present study is: do transform faults related to the Eurasia/Nubia plate boundary exist in the Azores? Knowing that the main source of strain is related to plate kinematics, we conclude that the sinistral strike-slip NNW-SSE fault plane solution is not consistent with either the fault dip (ca. 65, which is typical of a normal fault) or the ca. ENE-WSW direction of maximum extension; both are consistent with a normal fault, as observed in most major earthquakes on faults striking around NNW-SSE in the Azores. In contrast, the dextral strike-slip ENE-WSW fault plane solution is consistent with the transform direction related to the anticlockwise rotation of Nubia relative to Eurasia. Altogether, tectonic data, measured ground motion, observed destruction, and modelling are consistent with a dextral strike-slip source fault striking ENE-WSW. Furthermore, the bulk clockwise rotation measured by GPS is typical of bookshelf block rotations observed at the termination of such master strike-slip faults. Therefore, we suggest that the 1998 earthquake can be related to the WSW termination of a transform (ENE-WSW fault plane solution) associated with the Nubia-Eurasia diffuse plate boundary. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
1. INTRODUÇÃO; 2. PROCEDIMENTOS DE ENTREGA DA DISSERTAÇÃO; 3. ESTRUTURA DA DISSERTAÇÃO; 4. FORMATAÇÃO; 5. CITAÇÕES; 6. CONCLUSÃO; BIBLIOGRAFIA; APÊNDICES
Resumo:
Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.
Resumo:
Mestrado em Ensino da Música.
Resumo:
Basidiomycete strains synthesize several types of beta-D-glucans, which play a major role in the medicinal properties of mushrooms. Therefore, the specific quantification of these beta-D-glucans in mushroom strains is of great biochemical importance. Because published assay methods for these beta-D-glucans present some disadvantages, a novel colorimetric assay method for beta-D-glucan with alcian blue dye was developed. The complex formation was detected by following the decrease in absorbance in the range of 620 nm and by hypsochromic shift from 620 to 606 nm (similar to 14 nm) in UV-Vis spectrophotometer. Analysis of variance was used for optimization of the slope of the calibration curve by using the assay mixture containing 0.017% (w/v) alcian blue in 2% (v/v) acetic acid at pH 3.0. The high-throughput colorimetric assay method on microtiter plates was used for quantification of beta-D-glucans in the range of 0-0.8 mu g, with a slope of 44.15 x 10(-2) and a limit of detection of 0.017 mu g/well. Recovery experiments were carried out by using a sample of Hericium erinaceus, which exhibited a recovery of 95.8% for beta-1,3-D-glucan. The present assay method exhibited a 10-fold higher sensitivity and a 59-fold lower limit of detection compared with the published method with congo red beta-D-glucans of several mushrooms strains were isolated from fruiting bodies and mycelia, and they were quantified by this assay method. This assay method is fast, specific, simple, and it can be used to quantify beta-D-glucans from other biological sources. (C) 2015 American Institute of Chemical Engineers