24 resultados para Qualidade do ar - Monitorização - Cabo Verde
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Fitness centres are special places where conditions for microbiological proliferation should be considered. Moisture due to human perspiration and water condensation as a result of human physical activities are prevalent in this type of buildings. Exposure to microbial contaminants is clinically associated with respiratory disorders and people who work out in polluted environments would be susceptible to contaminants. This work studied the indoor air contamination in three gymnasiums in Lisbon. The sampling was performed at two periods: at the opening (morning) and closing (night) of the three gymnasiums. The airborne bacterial and fungal populations were sampled by impaction directly onto Tryptic Soy Agar (for bacteria) and Malt Extract Agar (for fungi) plates, using a Merck MAS-100 air sampler. Higher bacterial concentrations were found at night as compared to the morning but the same behaviour was not found for fungal concentrations. Gram-negative catalase positive cocci were the dominant bacteria in indoor air samples of the studied gymnasiums. In this study, 21 genera/species of fungal colonies were identified. Chrysosporium sp., Chrysonilia sp., Neoscytalidium hialinum, Sepedonium sp. and Penicillium sp. were the most prevalent species identified in the morning, while Cladosporium sp., Penicillium sp., Chrysosporium sp., Acremonium sp. and Chrysonilia sp. were more prevalent at night. A well-designed sanitation and maintenance program for gymnasiums is needed to ensure healthier space for indoor physical activity.
Resumo:
Projeto para obtenção do Grau de Mestre em Teatro. Especialização em Artes Performativas — Escritas de Cena.
Resumo:
A relação entre as comunicações, os media e o império português é o tema principal do dossiê que se propõe. O volume tem uma base interdisciplinar, acolhendo estudos de comunicação, história, literatura, entre outros domínios dos estudos humanísticos e das ciências sociais, que contribuam para a melhor compreensão das relações entre as comunicações e a política imperial de Portugal desde o século XVIII até finais da década de 1970. A partir de uma perspectiva alargada de comunicação, que pode abranger as estruturas físicas de transporte e todas as formas de comunicação simbólica (correio, imprensa, mass media, literatura, arquitetura, iconografia, etc), encoraja-se a apresentação de estudos que esclareçam as articulações e tensões entre os mais diversos media e o estabelecimento e manutenção de um império português no Brasil, em Angola, Moçambique, São Tomé e Príncipe, Cabo Verde, Guiné-Bissau, India (Goa, Damão e Diu), Timor-Leste e Macau. Procuram-se pesquisas que privilegiem uma multiplicidade de perspectivas da metrópole e das colônias e que enfatizem as interações entre comunicação, política, economia, sociedade e identidades culturais e nacionais. Aceitam-se contribuições em tópicos como: Conjugações e conexões entre transportes e comunicação na dinâmica imperial; Relação entre missões exploratórias, cartografia, infraestruturas de comunicação e estabelecimento de um Império; Media e comemoracionismo; Imprensa, propaganda, opinião pública e domínio imperial; Imperialismo e cultura popular; Meios de comunicação nas colónias (imprensa, rádio, literatura), resistência e constituição de identidades nacionais.
Resumo:
The presence of microorganisms in ophthalmic instruments and surfaces can lead to the exposure of patients to several infections. However, there is no information regarding fungal and bacteria contamination in optical shops. This study aims to characterize fungi and bacteria contamination in air and surfaces from 10 optical shops covering also ophthalmic instruments. Air samples were collected through an impaction method onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%) used for fungi and Tryptic Soy Agar (TSA) supplemented with nystatin (0.2%) used for bacteria. Outdoor samples were also performed to be used as reference. Surface and equipment’s swab samples were also collected side-by-side. All the collected samples were incubated at 27ºC for 5 to 7 days (fungi) or at 30º for 7 days (bacteria). Regarding fungal distribution, thirteen different species/genera were found in the air, being the most common Alternaria sp. (62.0%). Eight different species/genera were identified in the surfaces, ranging from 2 to 5x104 CFU/m2, being the most common A. versicolor complex and Penicillium sp. (40.0%). The trial frames were the most contaminated equipment, since 50.0% of the collected samples were with countless colonies. The airborne bacterial population indicated higher concentrations in the contactology office (average: 133 CFU/m3) than in the client’s waiting rooms (average: 126 CFU/m3). The surface samples indicated bacterial concentrations ranging from 2x104 to 1x106 CFU/m2, pointing out the automatic refractometer as the surface with higher bacterial load.
Resumo:
Introduction - Some studies point to human activities as one of the responsible for most bacterial concentration. However, there is no information regarding bacteria contamination in hotel room during the cleaning activity. Aim of the study - This study aims to assess and characterize the occupational exposure of bacterial contamination in hotel rooms, more precisely in a room with carpet floor and another room without carpet, during the cheaning activity.
Resumo:
Em arquivos e bibliotecas a presença de fungos é considerada nefasta pelas suas implicações na conservação e leitura de documentos históricos e pela sua associação a problemas de saúde sentidos pelos funcionários e utentes que frequentam estes locais. De acordo com alguns autores, os problemas de saúde mais reportados por funcionários em Bibliotecas e Arquivos são dermatite, rinite, alergias e asma. Embora revestida de inegável importância, existem poucos estudos internacionais sobre a temática e, em Portugal, a contaminação fúngica em ambiente arquivístico e em bibliotecas é ainda muito pouco conhecida. O estudo realizado em quatro Arquivos Portugueses teve como objectivo conhecer a contaminação fúngica, contribuindo para a análise da qualidade do ar interior desses espaços e sua comparação com estudos internacionais. Para isso foram recolhidas amostras de ar e de superfícies e estas foram analisadas por métodos clássicos de cultura e, quando necessário, por métodos de biologia molecular. A avaliação foi feita quantitativa e qualitativamente, considerando os requisitos legais em vigor. No que respeita à análise do ar, o número de unidades formadoras de colónias (UFC)/m3 nunca excedeu as 500 (limite legislado), tendo sido verificada contaminação interior em todos os locais estudados. Comparativamente aos estudos realizados anteriormente em contextos semelhantes foram encontrados níveis elevados de contaminação por leveduras nas amostras de ar analisadas em Arquivos Portugueses. Não foi identificado nenhum fungo patogénico neste estudo, mas em quase todas as amostras estavam presentes fungos potencialmente toxinogénicos. Dentro do grupo dos Aspergillus, o A.versicolor mostrou predominância, tendo este fungo reconhecidas capacidades de emissão de micotoxinas em ambiente de interior. A inclusão de amostras de superfície revelou-se vital para conhecer todo o espectro fúngico existente em cada um dos locais estudados, incluindo a detecção de Stachybotrys chartarum e a do fungo potencialmente queratinofílico, Chrysosporium carmichaelli. Tanto para a saúde como para a conservação, o recente estudo realizado em quatro arquivos permitiu retirar importantes conclusões e reforçar a necessidade de vigilância, sendo também útil para a definição de padrões de qualidade no campo do património cultural.
Resumo:
Poor hospital indoor air quality (IAQ) may lead to hospital-acquired infections, sick hospital syndrome and various occupational hazards. Air-control measures are crucial for reducing dissemination of airborne biological particles in hospitals. The objective of this study was to perform a survey of bioaerosol quality in different sites in a Portuguese Hospital, namely the operating theater (OT), the emergency service (ES) and the surgical ward (SW). Aerobic mesophilic bacterial counts (BCs) and fungal load (FL) were assessed by impaction directly onto tryptic soy agar and malt extract agar supplemented with antibiotic chloramphenicol (0.05%) plates, respectively using a MAS-100 air sampler. The ES revealed the highest airborne microbial concentrations (BC range 240-736 CFU/m(3) CFU/m(3); FL range 27-933 CFU/m(3)), exceeding, at several sampling sites, conformity criteria defined in national legislation [6]. Bacterial concentrations in the SW (BC range 99-495 CFU/m(3)) and the OT (BC range 12-170 CFU/m(3)) were under recommended criteria. While fungal levels were below 1 CFU/m(3) in the OT, in the SW (range 1-32 CFU/m(3)), there existed a site with fungal indoor concentrations higher than those detected outdoors. Airborne Gram-positive cocci were the most frequent phenotype (88%) detected from the measured bacterial population in all indoor environments. Staphylococcus (51%) and Micrococcus (37%) were dominant among the bacterial genera identified in the present study. Concerning indoor fungal characterization, the prevalent genera were Penicillium (41%) and Aspergillus (24%). Regular monitoring is essential for assessing air control efficiency and for detecting irregular introduction of airborne particles via clothing of visitors and medical staff or carriage by personal and medical materials. Furthermore, microbiological survey data should be used to clearly define specific air quality guidelines for controlled environments in hospital settings.
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Estruturas