41 resultados para preventive detention


Relevância:

10.00% 10.00%

Publicador:

Resumo:

International statistics show that the problem of the accidents at work is far away to be solved (ILO estimates that every year about 270 million work accidents and 160 million occupational diseases resulting in the death of more than 2 million workers occurs in the world). That's why the EU global goal concerning the community' strategy for occupational health and safety for 2007-2012 is to reduce in 25% the incidence rate of occupational accidents and diseases. In this prospect it is presented a case study which justify the need to develop studies in Safety, Hygiene and Health at Work area as a way to encourage the managers to implement preventive actions and strategies, besides meeting the legal requirements, in order to reduce the occurrence of work accidents, improve the work conditions and therefore obtain benefits in added values and reinforced competition. The general objective of this study is to describe the work situations, identify the dangers and associate the potential risks and consequences; evaluate and value the risk. The study uses the Failure Table methodology and, in the business area of an organization which will be from now on designated as MANTEM that works in the electromechanical maintenance area. The results were, amongst others, some actions to be implemented to eliminate/minimize risks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the printing industry, volatile organic compounds main sources are the uses of organic solvents, fountain solutions and cleaning agents. Nowadays, one circumstance which might confuse the exposure reality is that the majority of solvents which are often used have a faint odour. Therefore, the conditions at offset printing in regard to solvent exposure may seem acceptable to workers. Fortunately, general ventilation and local exhaust systems have also become more common, and new printing machines, often with automatic cleaning, have entered the market. The health effects of volatile organic solvents are dependent on the chemicals involved but, normally, are associated with affecting the nervous system, the liver and also the kidneys. The purpose of this study was to document the conditions regarding exposure to volatile organic compounds in an offset printing unit and to permit identify task with higher exposure and with priority for preventive measures application. Exposure assessment was done before and after installation of general ventilation and local exhaust equipments and during printing and cleaning procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório de estágio, que se realizou no Edifício Atrium Saldanha em Lisboa, tem por finalidade demonstrar as aptidões adquiridas no decorrer do Mestrado e que tornaram possíveis a participação num estágio que envolveu várias áreas da Engenharia Mecânica. Nos últimos anos, tem-se assistido a um crescente aumento do consumo e do custo da energia eléctrica. De acordo com análises realizadas pela União Europeia, uma percentagem significativa deste aumento de consumo está relacionado com edifícios e habitações. A manutenção preventiva das instalações técnicas é, entre outros aspectos, uma das ferramentas essenciais na redução desta factura energética. A questão que se coloca relaciona-se com a metodologia a aplicar para esse efeito. De que forma podem ou devem os planos de manutenção ser elaborados, qual a periodicidade das intervenções a considerar de modo a aumentar a eficiência energética dos edifícios, reduzir as emissões de dióxido de carbono e garantir uma maior protecção do utilizador? Numa fase inicial do estágio foi feita uma caracterização geral das principais instalações técnicas do edifício de modo a se analisarem, posteriormente, os procedimentos de manutenção adoptados pelas equipas de manutenção. Foram ainda sugeridas algumas periodicidades para os procedimentos de manutenção já existentes e algumas intervenções que não estavam incluídas no plano de manutenção do edifício e que podem contribuir para aumentar a fiabilidade dos equipamentos e consequentemente a eficiência energética e a qualidade do ar interior dos edifícios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Qualidade e Tecnologias da Saúde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório de estágio enquadra-se no âmbito do trabalho final de Mestrado do curso de Engenharia Civil, área de especialização em Hidráulica, do Instituto Superior de Engenharia de Lisboa, e incide na temática dos sistemas de distribuição de água. O estágio decorreu na empresa EPAL – Empresa Portuguesa das Águas Livres, S.A., e teve como objecto o desenvolvimento de um plano de manutenção preventiva para a rede de distribuição de água de Lisboa. Devido à crescente complexidade dos sistemas de abastecimento de água e à grande dispersão territorial dos diversos órgãos integrados na rede, surge a necessidade de desenvolver um sistema que permita simplificar o planeamento e a gestão das intervenções de inspecção e manutenção preventiva dos órgãos. Para esse efeito, recorreu-se a um software SIG (Sistema de Informação Geográfica) para proceder à sectorização da rede de distribuição de água em pequenos grupos (Polígonos), constituídos por um número determinado de órgãos de manobra e segurança. Esta metodologia permite organizar as intervenções em pequenos grupos e optimizar as rotinas de Inspecção diárias. No decorrer do estágio efectuou-se ainda um levantamento dos procedimentos de inspecção e manutenção dos diversos órgãos integrados na rede de distribuição de água de Lisboa, quer por acompanhamento de actividades com as equipas de inspecção, quer por recolha de recomendações junto dos fabricantes dos órgãos. Este levantamento permitiu elaborar fichas de procedimento para as actividades de inspecção e manutenção preventiva dos diversos órgãos, afim de serem usadas como referência pelos trabalhadores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Qualidade e Tecnologias da Saúde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Educação de Lisboa para a obtenção do grau de mestre em Ciências da Educação - Especialidade em Educação Social e Intervenção Comunitária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poor air quality in a pig-confinement building may potentially place farmers at higher health risk than other workers for exposure to airborne pollutants that may reach infectious levels. The aim of this study was to assess worker exposure to fungi in indoor environments in Portuguese swine buildings. Air samples from 7 swine farms were collected at a flow rate of 140 L/min, at 1 m height, onto malt extract agar supplemented with chloramphenicol (MEA). Surfaces samples of the same indoor sites were obtained by swabbing the surfaces. Samples from the floor covering were also collected from four of seven swine farms. All collected samples were incubated at 27°C for 5-7 days. After lab processing and incubation of obtained samples, quantitative colony-forming units (CFU)/m(3), CFU/cm(2), and CFU/g and qualitative results were determined with identification of isolated fungal species. Aspergillus versicolor was the most frequent species found in air (21%), followed by Scopulariopsis brevicaulis (17%) and Penicillium sp. (14%). Aspergillus versicolor was also the most frequent species noted on surfaces (26.6%), followed by Cladosporium sp. (22.4%) and Scopulariopsis brevicaulis (17.5%). Chrysosporium was the most frequently found genera in the new floor covering (38.5%), while Mucor was the most prevalent genera (25.1%) in used floor covering. Our findings corroborate a potential occupational health threat due to fungi exposure and suggest the need for a preventive strategy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aspergillus is among a growing list of allergens that aggravate asthmatic responses. Significant pulmonary pathology is associated with Aspergillus-induced allergic and asthmatic lung disease. Environments with high levels of exposure to fungi are found in animal production facilities such as for swine and poultry, and farmers working with these are at increased risk for occupational respiratory diseases. Seven Portuguese poultry and seven swine farms were analyzed in order to estimate the prevalence, amount, and distribution of Aspergillus species, as well as to determine the presence of clinical symptoms associated with asthma and other allergy diseases in these highly contaminated settings. From the collected fungal isolates (699), an average incidence of 22% Aspergillus was detected in poultry farms, while the prevalence at swine farms was 14%. The most frequently isolated Aspergillus species were A. versicolor, A. flavus, and A. fumigatus. In poultry farms, A. flavus presented the highest level of airborne spores (>2000 CFU/m3), whereas in swine farms the highest was A. versicolor, with an incidence fourfold greater higher than the other mentioned species. Eighty workers in these settings were analyzed, ranging in age from 17 to 93 yr. The potentially hazardous exposure of poultry workers to mold allergens using sensitization markers was evaluated. Although no significant positive association was found between fungal contamination and sensitization to fungal antigens, a high incidence of respiratory symptoms in professionals without asthma was observed, namely, wheezing associated with dyspnea (23.8%) and dyspnea after strenuous activities (12.3%), suggesting underdiagnosed respiratory disturbances. Further, 32.5% of all exposed workers noted an improvement of respiratory ability during resting and holidays. From all the analyzed workers, seven were previously diagnosed with asthma and four reported the first attack after the age of 40 yr, which may be associated with their occupational exposure. Some of the fungi, namely, the Aspergillus species detected in this study, are known to induce hypersensitivity reactions in humans. This study confirmed the presence and distribution of Aspergillus in Portuguese poultry and swine farms, suggesting a possible occupational health problem and raising the need for preventive and protective measures to apply to avoid exposure in both occupational settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os Hospitais, equipamentos de interesse público, são edifícios cujos desempenho e disponibilidade das suas instalações e equipamentos podem comprometer a prestação de cuidados de saúde, pelo que nestes estabelecimentos, a Manutenção Preventiva assume um papel relevante. Nesse sentido, pretendeu-se nesta dissertação definir uma estratégia específica que permita efectuar o planeamento da manutenção preventiva de um edifício hospitalar, enquanto infraestrutura para desenvolvimento da actividade clínica. Para tal, foi efectuada uma pesquisa bibliográfica, com a qual se identificaram conceitos de manutenção e requisitos a serem tidos em conta na manutenção de edifícios hospitalares. Foi efectuada uma caracterização genérica do objecto de manutenção, limitada no âmbito desta dissertação às principais componentes dos sistemas de construção e das instalações de águas e esgotos, que podem integrar um edifício hospitalar actual, atendendo às especificações e recomendações técnicas vigentes para este tipo de edifícios. Foram identificados os objectivos e requisitos de manutenção nestes edifícios, estabelecidos pelas condições de funcionamento pretendidas, pelos critérios de durabilidade exigidos pelo Dono de Obra, pelo nível de desempenho funcional requerido para as suas componentes e pelo grau de operacionalidade imposto nas suas diferentes unidades funcionais. Tendo em consideração que a criticidade de uma componente não depende só do contexto operacional da área funcional em se insere mas também das consequências que o seu estado de funcionamento pode acarretar para a unidade funcional. Foi exemplificada a análise dos modos de falha, sua criticidade e seus efeitos para hierarquização do risco associado nas componentes estudadas. As fichas exemplificativas dos planos de manutenção preventiva, que se apresentam no âmbito desta dissertação para algumas componentes básicas, integram acções e procedimentos que derivam de uma análise aos seus modos de falha e seus efeitos, bem como de recomendações técnicas exigências da regulamentação em vigor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Segurança e Higiene do Trabalho.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A calibração e o controlo da qualidade de um acelerador linear são passos muito importantes num serviço de Radioterapia, para garantir a qualidade dos tratamentos prestados. O sector da Física da Unidade de Radioterapia do Hospital Cuf Descobertas implementou um rigoroso Programa de controlo de qualidade ao equipamento produtor de radiação e aos equipamentos medidores de radiação, de acordo com o Dec-Lei 180/2002 e com os protocolos internacionais. Para tal, foram implementados procedimentos, criadas folhas de cálculo, instruções de trabalho e impressos. Foram ainda implementados testes aos equipamentos com periodicidade definida: controlo de qualidade diário e controlo de qualidade após intervenções (manutenções preventivas e correctivas). No decorrer do ano de 2005, o sector da Física colaborou activamente com toda a equipa da Radioterapia na implementação da Norma ISO 9001:2000 no serviço, contribuindo com o seu know how na implementação desta, numa área tão importante como a da garantia da qualidade dos feixes de radiação e das respectivas calibrações em dose. Numa procura de melhoria contínua da qualidade dos serviços prestados aos pacientes, decorre ainda uma auditoria externa da EQUAL-ESTRO*, intercomparação postal com dosímetros termoluminescentes. A qualidade dos feixes de energias utilizados diariamente é analisada, tanto ao nível das calibrações absolutas de cada um dos feixes de fotões e de electrões, como ao nível dos cálculos de dose obtidos com o sistema de planimetria XiO da CMS. Os resultados das duas primeiras fases da intercomparação, relativa aos dois feixes de fotões de 6 MV e 15 MV e feixes de electrões de 4 MeV, 8 MeV e 12 MeV, foram considerados pela EQUAL-ESTRO num nível óptimo (desvio máximo na dose medida em relação à dose de referência |d| ≤ 3%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica Ramo Manutenção e Produção

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica Ramo de processos químicos