3 resultados para welding procedure test

em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumo: 1 – Sumário do Acórdão do Supremo Tribunal de Justiça, de 28 de Setembro de 2011; 2 – Texto completo do Acórdão do Supremo Tribunal de Justiça, de 28 de Setembro de 2011, Juiz Conselheiro Raul BORGES (Relator), Juiz Conselheiro Armindo MONTEIRO cfr. http://www.dgsi.pt , 20 de Janeiro de 2012; 3 – Anotação; 3.1 – Introdução à anotação; 3.2 – Algumas das referências, por parte do Acórdão do Supremo Tribunal de Justiça, de 28 de Setembro de 2011, aos problemas do direito ao silêncio e do dever em o arguido se sujeitar a aplicações de prova no processo penal; 3.3 – «Teoria geral» dos problemas do direito ao silêncio em contraste com o dever de sujeição do arguido a diligências de prova no contexto do direito processual penal lusitano; 4 - Conclusão. § Abstract: 1 - Summary of the Judgement of the Supreme Court of Justice of 28 September 2011 2 - Full text of the Judgement of the Supreme Court of Justice of 28 September 2011, Councillor Judge Raul Borges (Reporter), Councillor Judge Armindo Monteiro cf. . http://www.dgsi.pt, January 20, 2012, 3 - Note: 3.1 - Introduction to the annotation; 3.2 - Some of the references, by the Judgement of the Supreme Court of Justice of 28 September 2011, the problems the right to silence and the duty in the defendant be subject to applications of proof in criminal proceedings; 3.3 - "general Theory" of the problems the right to silence in contrast to the duty of subjection of the accused to proof steps in the right context criminal procedure Lusitanian 4 - Conclusion. P.S.: este é o "abstract" tal qual como surge no artigo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O− is administered. This procedure may lead to the depletion of stock reserves of O− blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.