56 resultados para synchronous generators
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This paper presents a novel graphical approach to adjust and evaluate frequency-based relays employed in anti-islanding protection schemes of distributed synchronous generators, in order to meet the anti-islanding and abnormal frequency variation requirements, simultaneously. The proposed method defines a region in the power mismatch space, inside which the relay non-detection zone should be located, if the above-mentioned requirements must be met. Such region is called power imbalance application region. Results show that this method can help protection engineers to adjust frequency-based relays to improve the anti-islanding capability and to minimize false operation occurrences, keeping the abnormal frequency variation utility requirements satisfied. Moreover, the proposed method can be employed to coordinate different types of frequency-based relays, aiming at improving overall performance of the distributed generator frequency protection scheme. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This paper compares the behaviour of two different control structures of automatic voltage regulators of synchronous machines equipped with static excitation systems. These systems have a fully controlled thyristor bridge that supplies DC current to the rotor winding. The rectifier bridge is fed by the stator terminals through a step-down transformer. The first control structure, named ""Direct Control"", has a single proportional-integral (PI) regulator that compares stator voltage setpoint with measured voltage and acts directly on the thyristor bridge`s firing angle. This control structure is usually employed in commercial excitation systems for hydrogenerators. The second structure, named ""Cascade Control"", was inspired on control loops of commercial DC motor drives. Such drives employ two PIs in a cascade arrangement, the external PI deals with the motor speed while the internal one regulates the armature current. In the adaptation proposed, the external PI compares setpoint with the actual stator voltage and produces the setpoint to the internal PI-loop which controls the field current.
Resumo:
In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transistors (IGBT). According to new grid code requirements, wind turbines must remain connected to the grid during grid disturbances. Moreover, they must also contribute to voltage support during and after grid faults. The crowbar system is essential to avoid the disconnection of the doubly fed induction wind generators from the network during faults. The insertion of the crowbar in the rotor circuits for a short period of time enables a more efficient terminal voltage control. As a general rule, the activation and the deactivation of the crowbar system is based only on the DC-link voltage level of the back-to-back converters. In this context, the authors discuss the critical rotor speed to analyze the instability of doubly fed induction generators during grid faults.
Resumo:
Let A be an iterated tilted algebra. We will construct an Auslander generator M in order to show that the representation dimension of A is three in case A is representation infinite.
Resumo:
This paper presents a robust voltage control scheme for fixed-speed wind generators using a static synchronous compensator (STATCOM) controller. To enable a linear and robust control framework with structured uncertainty, the overall system is represented by a linear part plus a nonlinear part that covers an operating range of interest required to ensure stability during severe low voltages. The proposed methodology is flexible and readily applicable to larger wind farms of different configurations. The performance of the control strategy is demonstrated on a two area test system. Large disturbance simulations demonstrate that the proposed controller enhances voltage stability as well as transient stability of induction generators during low voltage ride through (LVRT) transients and thus enhances the LVRT capability. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The combined-cycle gas and steam turbine power plant presents three main pieces of equipment: gas turbines, steam turbines and heat recovery steam generator (HRSG). In case of HRSG failure the steam cycle is shut down, reducing the power plant output. Considering that the technology for design, construction and operation of high capacity HRSGs is quite recent its availability should be carefully evaluated in order to foresee the performance of the power plant. This study presents a method for reliability and availability evaluation of HRSGs installed in combined-cycle power plant. The method`s first step consists in the elaboration of the steam generator functional tree and development of failure mode and effects analysis. The next step involves a reliability and availability analysis based on the time to failure and time to repair data recorded during the steam generator operation. The third step, aiming at availability improvement, recommends the fault-tree analysis development to identify components the failure (or combination of failures) of which can cause the HRSG shutdown. Those components maintenance policy can be improved through the use of reliability centered maintenance (RCM) concepts. The method is applied on the analysis of two HRSGs installed in a 500 MW combined-cycle power plant. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Second-order phase locked loops (PLLs) are devices that are able to provide synchronization between the nodes in a network even under severe quality restrictions in the signal propagation. Consequently, they are widely used in telecommunication and control. Conventional master-slave (M-S) clock-distribution systems are being, replaced by mutually connected (MC) ones due to their good potential to be used in new types of application such as wireless sensor networks, distributed computation and communication systems. Here, by using an analytical reasoning, a nonlinear algebraic system of equations is proposed to establish the existence conditions for the synchronous state in an MC PLL network. Numerical experiments confirm the analytical results and provide ideas about how the network parameters affect the reachability of the synchronous state. The phase-difference oscillation amplitudes are related to the node parameters helping to design PLL neural networks. Furthermore, estimation of the acquisition time depending on the node parameters allows the performance evaluation of time distribution systems and neural networks based on phase-locked techniques. (c) 2008 Elsevier GmbH. All rights reserved.
Resumo:
In many engineering applications, the time coordination of geographically separated events is of fundamental importance, as in digital telecommunications and integrated digital circuits. Mutually connected (MC) networks are very good candidates for some new types of application, such as wireless sensor networks. This paper presents a study on the behavior of MC networks of digital phase-locked loops (DPLLs). Analytical results are derived showing that, even for static networks without delays, different synchronous states may exist for the network. An upper bound for the number of such states is also presented. Numerical simulations are used to show the following results: (i) the synchronization precision in MC DPLLs networks; (ii) the existence of synchronous states for the network does not guarantee its achievement and (iii) different synchronous states may be achieved for different initial conditions. These results are important in the neural computation context. as in this case, each synchronous state may be associated to a different analog memory information. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A 50-year-old woman presented with pancreatitis, fluctuant jaundice, weight loss, and abdominal pain. Contrast-enhanced computed tomography and abdominal ultrasound showed slight dilatation of the biliary tree and gallbladder without calculi. Endoscopy demonstrated a tumor protruding from the papilla of Vater. First endoscopically biopsy diagnosed no tumor, and a second biopsy diagnosed as papillary adenocarcinoma. The patient underwent duodenopancreatectomy. The specimen was fixed in formalin (10%). The tissue was processed routinely, and paraffin sections were stained with hematoxylin-eosin and periodic acid Schiff. Gross examination showed two tumors seen as prolapsed nodules growing isolated from the minor and major duodenal papillae measuring 1.5 and 1.0 cm, respectively, both covered by duodenal mucosa and the histologic study of both lesions demonstrated a moderately differentiated tubular adenocarcinoma, which invaded duodenal wall. After surgery, she is alive 24 months without evidence of recurrence.
Resumo:
Collision tumors consist of two independent but coexisting tumors. This uncommon situation might be easily mistaken for a composite tumor where one histogenetic event originates from two apparently distinct neoplasms. Colorectal collisions are particularly unusual; here, we report the exceedingly rare case of a 61-year-old man with malignant melanoma and adenocarcinoma colliding in the rectum. Collision tumors have an idiopathic pathophysiology and in fact ""accidental meeting"" is accepted by many authors. This article discusses the concepts about cancer development, which are overlooked by this hypothesis, another theory to explain that this rare occurrence involves microenvironment changes.
Resumo:
Promoting the inclusion of students with disabilities in e-learning systems has brought many challenges for researchers and educators. The use of synchronous communication tools such as interactive whiteboards has been regarded as an obstacle for inclusive education. In this paper, we present the proposal of an inclusive approach to provide blind students with the possibility to participate in live learning sessions with whiteboard software. The approach is based on the provision of accessible textual descriptions by a live mediator. With the accessible descriptions, students are able to navigate through the elements and explore the content of the class using screen readers. The method used for this study consisted of the implementation of a software prototype within a virtual learning environment and a case study with the participation of a blind student in a live distance class. The results from the case study have shown that this approach can be very effective, and may be a starting point to provide blind students with resources they had previously been deprived from. The proof of concept implemented has shown that many further possibilities may be explored to enhance the interaction of blind users with educational content in whiteboards, and further pedagogical approaches can be investigated from this proposal. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The generalized Birnbaum-Saunders distribution pertains to a class of lifetime models including both lighter and heavier tailed distributions. This model adapts well to lifetime data, even when outliers exist, and has other good theoretical properties and application perspectives. However, statistical inference tools may not exist in closed form for this model. Hence, simulation and numerical studies are needed, which require a random number generator. Three different ways to generate observations from this model are considered here. These generators are compared by utilizing a goodness-of-fit procedure as well as their effectiveness in predicting the true parameter values by using Monte Carlo simulations. This goodness-of-fit procedure may also be used as an estimation method. The quality of this estimation method is studied here. Finally, through a real data set, the generalized and classical Birnbaum-Saunders models are compared by using this estimation method.
Resumo:
Reconhecer com precisão indivíduos com maior risco imediato de morte súbita cardíaca (MSC) ainda é uma questão em aberto. A natureza fortuita dos eventos cardiovasculares agudos não parece se adequar ao conhecido modelo de indução de taquicardia/fibrilação ventricular por um gatilho em sincronia a um substrato arritmogênico estático. Quanto ao mecanismo da MSC, uma instabilidade elétrica dinâmica explicaria melhor a raridade da associação simultânea de um gatilho certo a um substrato cardíaco apropriado. Diversos estudos tentaram medir essa instabilidade elétrica cardíaca (ou um equivalente válido) em uma sequência de batimentos cardíacos no ECG. Dentre os mecanismos possíveis podemos citar o prolongamento do QT, dispersão do QT, potenciais tardios, alternância de onda T ou T-wave alternans (TWA), e turbulência da frequência cardíaca. Este artigo se atém em particular ao papel da TWA no panorama atual da estratificação de risco cardíaco. Os achados sobre TWA ainda são heterogêneos, variando de um desempenho prognóstico muito bom até um quase nulo, dependendo da população clínica observada e protocolo clínico usado. Para preencher as atuais lacunas no conhecimento sobre TWA, profissionais médicos e pesquisadores devem explorar melhor as características técnicas das diversas tecnologias disponíveis para a avaliação de TWA e atentar ao fato de que os valores de TWA respondem a diversos outros fatores, além de medicamentos. Informações sobre mecanismos celulares e subcelulares da TWA estão fora do escopo deste artigo, mas são referenciados alguns dos principais trabalhos sobre este tópico, com o intuito de auxiliar no entendimento dos conceitos e fatos cobertos neste artigo.
Resumo:
OBJETIVO: O objetivo deste trabalho foi estudar a grandeza practical peak voltage (PPV), determinada a partir da forma de onda de tensão aplicada a tubos radiológicos, e compará-la com algumas definições de kVp para diferentes tipos de geradores: monofásico (onda completa, clínico), trifásico (seis pulsos, clínico) e potencial constante (industrial). MATERIAIS E MÉTODOS: O trabalho envolveu a comparação do PPV medido invasivamente (utilizando um divisor de tensão) com a resposta de dois medidores comerciais não invasivos, além dos valores de outras grandezas usadas para medição da tensão de pico aplicada ao tubo de raios X, e a análise da variação do PPV com a ondulação percentual da tensão (ripple). RESULTADOS: Verificou-se que a diferença entre o PPV e as definições mais comuns de tensão de pico aumenta com o ripple. Os valores de PPV variaram em até 3% e 5%, respectivamente, na comparação entre medições invasivas e não invasivas feitas com os equipamentos trifásico e monofásico. CONCLUSÃO: Os resultados demonstraram que a principal grandeza de influência que afeta o PPV é o ripple da tensão. Adicionalmente, valores de PPV obtidos com medidores não invasivos devem ser avaliados considerando que eles dependem da taxa de aquisição e da forma de onda adquirida pelo instrumento.
Resumo:
Synchronization plays an important role in telecommunication systems, integrated circuits, and automation systems. Formerly, the masterslave synchronization strategy was used in the great majority of cases due to its reliability and simplicity. Recently, with the wireless networks development, and with the increase of the operation frequency of integrated circuits, the decentralized clock distribution strategies are gaining importance. Consequently, fully connected clock distribution systems with nodes composed of phase-locked loops (PLLs) appear as a convenient engineering solution. In this work, the stability of the synchronous state of these networks is studied in two relevant situations: when the node filters are first-order lag-lead low-pass or when the node filters are second-order low-pass. For first-order filters, the synchronous state of the network shows to be stable for any number of nodes. For second-order filter, there is a superior limit for the number of nodes, depending on the PLL parameters. Copyright (C) 2009 Atila Madureira Bueno et al.