296 resultados para spacing between nozzles
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
It is well known that striation spacing may be related to the crack growth rate, da/dN, through Paris equation, as well as the maximum and minimum loads under service loading conditions. These loads define the load ratio, R, and are considered impossible to be evaluated from the inter-spacing striations analysis. In this way, this study discusses the methodology proposed by Furukawa to evaluate the maximum and minimum loads based on the experimental fact that the relative height of a striation, H, and the striation spacing, s, are strongly influenced by the load ratio, R. Fatigue tests in C(T) specimens were conducted on SAE 7475-T7351 Al alloy plates at room temperature and the results showed a straightforward correlation between the parameters H, s, and R. Measurements of striation height, H, were performed using scanning electron microscopy and field emission gun (FEG) after sectioning the specimen at a large inclined angle to amplify the height of the striations. The results showed that for increasing R the values of H/s tend to increase. Striation height, striation spacing, and load ratio correlations were obtained, which allows one to estimate service loadings from fatigue fracture surface survey.
Resumo:
The possible states in the flow around two identical circular cylinders in tandem arrangements are investigated for configurations in the vicinity of the drag inversion separation. By means of numerical simulations, the hysteresis in the transition between the shedding regimes is studied and the relationship between (three-dimensional) secondary instabilities and shedding regime determination is addressed. The differences observed in the behavior of two- and three-dimensional flows are analyzed, and the regions of bistable flow are delimited. Very good agreement is found between the proposed scenario and results available in the literature. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3420111]
Resumo:
Organic-inorganic hybrid materials can be prepared dispersing organic species into well-defined inorganic nanoblocks. This paper describes the immobilization of natural dyes from the extract of the Brazilian acai-fruit into two types of layered hexaniobate precursors derived from H(2)K(2)Nb(6)O(17): (i) colloidal dispersion of niobate exfoliated nanoparticles and (ii) niobate pre-intercalated with tetraethylammonium cations (TEA(+)). The restacking of exfoliated particles in the presence of acai anthocyanins promotes their intercalation and produces stacked layers showing large basal spacing (ca. 50 angstrom). The TEA(+) pre-intercalated niobate provides particles with lower content of dye species than the exfoliated precursor but with higher degree of organization and regularity according to X-ray diffraction data and images obtained by electron microscopies. Vibrational (FTIR and Raman) and (13)C NMR spectroscopies indicate the presence of flavylium cations in the hybrid materials and spectral profiles characteristic of glycosylated anthocyanidins. According to thermal analysis results, the purplish hybrids materials are more stable than the free acai-dyes. One hybrid sample was heated under air up to 170 degrees C and maintained at this temperature for 240 min. No weight loss events were observed and the sample retained its original color, indicating that the intercalation of anthocyanin into hexaniobate increases its thermal stability. Considering the structural, chemical, optical and thermal properties of the synthesized hybrid materials, they might be good candidates to be investigated for future specialized applications.
Resumo:
Alloys of Al-Sn and Al-Si are widely used in tribological applications such as cylinder liners and journal bearings. Studies of the influence of the as-cast microstructures of these alloys on the final mechanical properties and wear resistance can be very useful for planning solidification conditions in order to permit a desired level of final properties to be achieved. The aim of the present study was to contribute to a better understanding about the relationship between the scale of the dendritic network and the corresponding mechanical properties and wear behavior. The Al-Sn (15 and 20 wt pct Sn) and Al-Si (3 and 5 wt pct Si) alloys were directionally solidified under unsteady-state heat flow conditions in water-cooled molds in order to permit samples with a wide range of dendritic spacings to be obtained. These samples were subjected to tensile and wear tests, and experimental quantitative expressions correlating the ultimate tensile strength (UTS), yield tensile strength, elongation, and wear volume to the primary dendritic arm spacing (DAS) have been determined. The wear resistance was shown to be significantly affected by the scale of primary dendrite arm spacing. For Al-Si alloys, the refinement of the dendritic array improved the wear resistance, while for the Al-Sn alloys, an opposite effect was observed, i.e., the increase in primary dendrite arm spacing improved the wear resistance. The effect of inverse segregation, which is observed for Al-Sn alloys, on the wear resistance is also discussed.
Correlation between margin fit and microleakage in complete crowns cemented with three luting agents
Resumo:
Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.
Resumo:
This study analyzed the association of periodontal disease (PD) and rheumatoid arthritis (RA). Seventy-five 35-60-year-old patients were assigned to 5 groups according to the presence (+) or not (-) of PD and RA and the treatment received (TR+) or not (TR-) for PD. Group 3 uses total prosthesis (TP). Clinical and laboratory evaluations were performed at baseline, 3 and 6 months of follow-up by probing pocket depth, bleeding on probing and plaque index for PD, HAQ, DAS28, SF-36 and laboratory: AAG, ESR, CRP for RA. Statistically significant differences for PD after 3 (p=0.0055) and after 6 months (p=0.0066) were obtained in Group 1 (RA+PD+TR+) and 2(RA+PD+TR-); significant reduction in the % of BOP after 6 months (p=0.0128) and significant reduction in the % of Pl after 3 (p=0.0128) and 6 months (p=0.0002) in Group 1. Statistically significant differences between Groups 1 and 3 (RA+TP) for DAS28 at baseline and after 3 months were observed, but not after 6 months. No other parameters for RA were significantly affected. The relationship between RA and PD disease activities is not clear, but the importance of periodontal treatment in the control of inflammation to avoid tooth extraction is evident.
Resumo:
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.
Resumo:
This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.
Resumo:
The dentist can offer athletes improvement in their physical performance through the maintenance of oral health, preventing and treating any and all changes in the stomatognathic system, such as dental malocclusions, that compromise the athletes' performance. The objective of this study is to research the presence of dental malocclusions in athletes of the category between 13 and 20 years of age, from the São Paulo Football Club. 84 athletes participated in this study, dealing with the following topics: molar relation (Angle's classification); presence of overbite; underbite; overcrowding; abnormal spacing; open bite; and anterior, posterior, bilateral and unilateral crossbite; midline deviation and facial type (mesofacial, brachyfacial and dolichofacial). Only one table was made, showing percentages. In regard to Angle's molar relation, 89% are in Class I, 8% in Class II, 3% Class III, 9% of the athletes had overbite, 4% had underbite, 13% had overcrowding and 21% had abnormal spacing. In regard to the bite, 11% presented anterior open bite. In regard to crossbite, 7% presented unilateral crossbite on the right side and 2% on the left side; 5% presented posterior crossbite and 4% anterior crossbite. In regard to midline deviations, 4% presented deviation in the maxilla and 33% in the mandible. In regard to facial type: 39% are dolichofacial, 4% brachyfacial and 57% mesofacial. Based on the results shown, proposals for the implementation of dental, phoniatric, and Ear, Nose and Throat (ENT) practices are already being discussed with the multidisciplinary team of the club involved.
Resumo:
Composite resins might be susceptible to degradation and staining when in contact with some foods and drinks. This study evaluated color alteration and changes in microhardness of a microhybrid composite after immersion in different colored foods and determined whether there was a correlation between these two variables. Eighty composite disks were randomly divided into 8 experimental groups (n = 10): kept dry; deionized water; orange juice; passion fruit juice; grape juice; ketchup; mustard and soy sauce. The disks were individually immersed in their respective test substance at 37 ºC, for a period of 28 days. Superficial analysis of the disk specimens was performed by taking microhardness measurements (Vickers, 50 g load for 45 seconds) and color alterations were determined with a spectrophotometer (CINTRA 10- using a CIEL*a*b* system, 400-700 nm wavelength, illuminant d65 and standard observer of 2º) at the following times: baseline (before immersion), 1, 7, 14, 21 and 28 days. Results were analyzed by ANOVA and Tukey's test (p < 0.05). Both variables were also submitted to Pearson's correlation test (p < 0.05). The passion fruit group underwent the greatest microhardness change, while the mustard group suffered the greatest color alteration. Significant positive correlation was found between the two variables for the groups deionized water, grape juice, soy sauce and ketchup. Not all color alteration could be associated with surface degradation.
Resumo:
The aim of this study was to investigate the agreement between diagnoses of calcified atheroma seen on panoramic radiographs and color Doppler images. Our interest stems from the fact that panoramic images can show the presence of atheroma regardless of the level of obstruction detected by color Doppler images. Panoramic and color Doppler images of 16 patients obtained from the archives of the Health Department of the city of Valença, RJ, Brazil, were analyzed in this study. Both sides of each patient were observed on the images, with a total of 32 analyzed cervical regions. The level of agreement between diagnoses was analyzed using the Kappa statistics. There was a high level of agreement, with a Kappa value of 0.78. In conclusion, panoramic radiographs can help detecting calcifications in the cervical region of patients susceptible to vascular diseases predisposing to myocardial infarction and cerebrovascular accidents. If properly trained and informed, dentists can refer their patients to a physician for a cardiovascular evaluation in order to receive proper and timely medical treatment.
Resumo:
There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis.
Resumo:
The aim of this study was to assess oral health status and its relationship with quality of life. A household population, cross-sectional study was carried out; participants were between 15 and 17 years of age (n = 247) and were examined by two calibrated dentists. Socio-economic status was classified according to ANEP-ABIPEME criteria. Clinical examinations to observe DMFT, CPI and Dean indices were performed as per WHO criteria. The Significant Caries Index (SiC) was used to evaluate polarization of the occurrence of caries among participants of the tercile with higher DMF-T. The OHIP instrument was used to measure quality of life. The Spearman and Mann-Whitney tests were used for assessing correlations (5% significance level). Examinations were carried out in 117 (47.37%) females and in 130 (52.63%) males. Of the examined participants, 45.75% were classified as belonging to socio-economic class C. Caries occurrence was observed in 218 subjects (88.26%); the mean DMFT was 5.40. The SiC index was 9.97. Almost half (47.77%) of the participants examined did not present sextants affected by periodontal disease. Of the participants examined, 80.16% presented absence of fluorosis. The mean OHIP was 3.95. The following correlations were observed: a positive and statistically significant correlation between the highest score in the OHIP and decayed teeth; a positive correlation with threshold significance between OHIP and DMFT; an inverse correlation between intact teeth and OHIP; and a positive and non statistically significant correlation between SiC and OHIP (correlation coefficient = 0.13, p = 0.245). Association between the mean OHIP and the terciles was not significant (p = 0.146); there were also no associations between periodontal condition and OHIP nor were there associations between the presence of fluorosis and mean OHIP.
Resumo:
The purpose of the present study was to assess the association between overbite and craniofacial growth pattern. The sample comprised eighty-six cephalograms obtained during the orthodontic pretreatment phase and analyzed using the Radiocef program to identify the craniofacial landmarks and perform orthodontic measurements. The variables utilized were overbite, the Jarabak percentage and the Vert index, as well as classifications resulting from the interpretation of these measurements. In all the statistical tests, a significance level of 5% was considered. Measurement reliability was checked by calculating method error. Weighted Kappa analysis showed that agreement between the facial types defined by the Vert index and the direction of growth trend established by the Jarabak percentage was not satisfactory. Owing to this lack of equivalency, a potential association between overbite and craniofacial growth pattern was evaluated using the chi-square test, considering the two methods separately. No relationship of dependence between overbite and craniofacial growth pattern was revealed by the results obtained. Therefore, it can be concluded that the classification of facial growth pattern will not be the same when considering the Jarabak and the Ricketts anayses, and that increased overbite cannot be associated with a braquifacial growth pattern, nor can openbite be associated with a dolichofacial growth pattern.