37 resultados para portable extractor

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As technology improves human vision, some procedures currently performed may be causing a decrease of the natural UV protection of the cornea. A portable dual beam system prototype was assembled for physicians for clinical studies of these effects on the corneas endowing two types of 300-400 nm evaluations: 1, regularly donated corneas and 2, simulating refractive keratectomy by corneal lamellae removal. The system performs 500 measurements/s, providing +/- 0.25% precision for the transmittance. The measurements performed on the prototype are 95% in agreement with Cary 17 and HR4000CG-UV-NIR Ocean Optics spectrophotometers. Preliminary studies on cadaveric corneas demonstrate that, as the stromal layer is reduced (similar to 150 mu m depth), there is significant loss-an average of 7.1%.-of the cornea's natural UV protection. The prototype is being tested in an eye bank for routine evaluation of donor corneas. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethnopharmacological importance: Many species of plants in the Brazilian cerrado (savanna) are widely used in ethnomedicine. However, the safety and effectiveness of medicinal plants used in communities with little or no access to manufactured drugs should be evaluated. Aim of the study: Evaluate the antimicrobial and cytotoxic activities of extracts from eight plant species, obtained using Brazilian cachaca as the extractor liquid. Materials and methods: The extracts were tested against Bacillus subtilis, Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Candida albicans, Candida parapsilosis, promastigote forms of Leishmania amazonensis, and poliovirus. In addition, cytotoxic activity was assayed in Vero cells and in human erythrocytes. Results: The plant species Curatella americana, Sclerolobium aureum, and Plathymenia reticulata showed the best activity against yeasts, especially the crude extract of C. americana and its ethyl-acetate fraction. Kielmeyera lathrophyton showed a minimum inhibitory concentration of 250 mu g/ml against S. aureus, and was inactive against Gram-negative bacteria. The extract obtained from Annona coriacea showed the best activity against the promastigote forms of Leishmania amazonensis (IC(50) = 175 mu g/ml). Only C. americana showed potential for antipoliovirus activity. The concentrations of the crude extracts that showed toxicity to VERO cells had CC(50) between 31 and 470 mu g/ml, and the lyophilized Brazilian cachaca showed a CC(50) of 307 mu g/ml. None of the extracts showed toxicity against human erythrocytes. Conclusions: Among the plant species studied. C americana proved to be effective against microorganisms, especially as an antifungal. The results will help in the search for alternative drugs to be used in pharmacotherapy, and will contribute to establish safe and effective use of phytomedicines in the treatment of infectious diseases. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assembling of a system for field sampling and activity concentration measurement of radon dissolved in groundwater is described. Special attention is given in presenting the calibration procedure to obtain the radon activity concentration in groundwater from the raw counting rate registered in a portable scintillation detector and in establishing the precision of the activity concentration measurements. A field procedure was established and the system tested during one year of monthly observations of (222)Rn activity concentration in groundwater drawn from two wells drilled on metamorphic rocks exposed at Eastern Sao Paulo State, Brazil. The observed mean (222)Rn activity concentrations are 374 Bq/dm(3) in one well and about 1275 Bq/dm(3) in the other one. In both wells the (222)Rn activity concentrations showed a seasonal variation similar to variations previously reported in the literature for the same region. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90 degrees, measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho avaliou o material de higiene bucal usado em escolas para estabelecer um protocolo às ações de higiene bucal coletiva. O estudo foi dividido em duas etapas: 1ª- 20 responsáveis pelos procedimentos coletivos com escolares de Bauru e São José dos Campos - SP responderam a dois questionários sobre o uso de cinco kits de higiene bucal coletiva. A análise estatística foi realizada através do teste Wilcoxon (p < 0,05); 2ª - 178 escolares de 4 a 8 anos de Bauru e Bariri-SP dispensaram na escova uma quantidade de creme dental e dentifrício líquido para a prática da escovação, a qual foi pesada através de uma balança portátil. A análise estatística foi obtida através do coeficiente de correlação de Pearson e a análise de covariância (p< 0,05). O kit 5 obteve graus de satisfação e muita satisfação quando comparado aos kits 1 a 4. A quantidade de creme dental dispensada pelos escolares foi em média 0,41g (Bauru) e 0,48g (Bariri). Não houve diferença estatística entre os escolares de Bauru e Bariri em relação ao dentifrício líquido (média de 0,15g). O dentifrício líquido, através da "técnica da gota", foi considerado prático, dispensando uma pequena quantidade padronizada. O kit 5 demonstrou ser uma boa alternativa ao estabelecimento de um protocolo de ações em saúde bucal coletiva no SUS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effects of a flavor-containing dentifrice on the formation of volatile sulphur compounds (VSCs) in morning bad breath. A two-step, blinded, crossover, randomized study was carried out in 50 dental students with a healthy periodontium divided into two experimental groups: flavor-containing dentifrice (test) and non-flavor-containing dentifrice (control). The volunteers received the designated dentifrice and a new toothbrush for a 3 X/day brushing regimen for 2 periods of 30 days. A seven-day washout interval was used between the periods. The assessed parameters were: plaque index (PI), gingival index (GI), organoleptic breath scores (ORG), VSC levels (as measured by a portable sulphide monitor) before (H1) and after (H2) cleaning of the tongue, tongue coating (TC) wet weight and BANA test from TC samples. The intra-group analysis showed a decrease in ORG, from 3 to 2, after 30 days for the test group (p < 0.05). The inter-group analysis showed lower values in ORG, H1 and H2 for the test group (p < 0.05). There was no difference between the amount of TC between groups and the presence of flavor also did not interfere in the BANA results between groups (p > 0.05). These findings suggest that a flavor-containing dentifrice seems to prevent VSCs formation in morning bad breath regardless of the amount of TC in periodontally healthy subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin after immersion in sodium hypochlorite (NaOCl), simulating 20 min of disinfection daily during 180 days. Forty disk-shaped (15 x 4 mm) and 40 rectangular (65 x 10 x 3 mm) specimens were prepared with a microwave-polymerized acrylic resin (Onda-Cryl). Specimens were immersed in either 0.5% NaOCl, 1% NaOCl, Clorox/Calgon and distilled water (control). Color measurements were determined by a portable colorimeter. Three parallel lines, separated by 1.0 mm, were registered on each specimen before and after immersion procedures to analyze the surface roughness. The flexural strength was measured using a 3-point bending test in a universal testing machine with a 50 kgf load cell and a crosshead speed of 1 mm/min. Data were analyzed statistically by ANOVA and Tukey's test (?=0.05). There was no statistically significant differences (p>0.05) among the solutions for color, surface roughness and flexural strength. It may be concluded that immersion in NaOCl solutions simulating short-term daily use during 180 days did not influence the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La comunidad científica que se ocupa de los problemas relacionados con el proceso de enseñanza-aprendizaje de la físicas, ha dedicado muchos esfuerzos en los ultimos años al perfeccionamiento del mismo, motivado en primera instancia, por las demandas de renovación que el impetuoso desarrollo científico-técnico le impone en la actualidad a la enseñanza de las ciencias. En los últimos años se ha producido un desarrollo vertiginoso en la fabricación de diodos láser que emiten en el espectro visible, esto ha permitido su utilización creciente en múltiples aplicaciones y hace factible su utilización en la enseñanza aprendizaje de la física universitaria y en particular de la holografía, por sus grandes ventajas frente a los láseres convencionales de gran costo y difícil manipulación. En el trabajo se describen la instalación experimental portátil diseñada para la obtención de hologramas en la escuela y en la casa con la utilización de diodos láser, la metodología de trabajo a seguir, los métodos de procesamiento utilizados para diferentes tipos de emulsiones holográficas y un análisis de los defectos que pueden presentar los hologramas producidos y la forma de detectarlos y erradicarlos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work it is presented the development of a simple, portable and inexpensive instrumentation for amperometric and coulometric detection in different analytical instrumentation systems utilizing ultramicroelectrodes. The software, developed in LabVIEW 7.1TM, is capable to carry out three main detection techniques (amperometric, pulsed amperometric and coulometric detection) and a voltammetric technique (cyclic voltammetry). The instrumentation was successfully evaluated using the following systems: cyclic voltammograms of metallic electrodes in alkaline solutions, flow electrochemical detection of glucose and glycine and direct determination of herbicide glyphosate (electrochemical detection coupled to HPLC).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar a acurácia de três pontos de corte na determinação da pressão arterial elevada em adolescentes, dada a forte relação entre o excesso de peso e valores elevados de pressão arterial. MÉTODOS: Participaram do estudo 1.021 adolescentes de ambos os sexos, selecionados de maneira aleatória nas escolas públicas e particulares de Londrina (PR). O peso corporal foi aferido por meio de balança digital, e a estatura, por um estadiômetro portátil com extensão máxima de 2 metros. A pressão arterial foi avaliada através de um aparelho automático. A capacidade do índice de massa corporal de detectar a pressão arterial elevada foi averiguada por meio da curva ROC e seus parâmetros (sensibilidade, especificidade e área sob a curva). RESULTADOS: Os pontos de corte da proposta nacional apresentaram maior acurácia (masculino: 0,636±0,038; feminino: 0,585±0,043) quando comparados aos pontos de corte das propostas internacional (masculino: 0,594±0,040; feminino: 0,570±0,044) e norte-americana (masculino: 0,612±0,039; feminino: 0,578±0,044). CONCLUSÃO: A proposta nacional foi a que apresentou melhor acurácia na indicação de valores elevados de pressão arterial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar alguns atributos químicos do solo e a disponibilidade de cádmio (Cd), cromo (Cr), níquel (Ni), mercúrio (Hg), chumbo (Pb) e arsênio (As), por meio da extração pelo DTPA,em conseqüência da aplicação superficial de escória de aciaria, lama cal e lodos de esgoto centrifugados e de biodigestores, nas doses 0 (testemunha), 2, 4 e 8 Mg ha-1 e um tratamento adicional composto pela calagem superficial na dose 2 Mg ha-1. O experimento foi conduzido em delineamento de blocos ao acaso, em condições de campo, em área sob sistema plantio direto, durante 2003 e 2004. A aplicação superficial de escória de aciaria,lama cal, lodo de esgoto centrifugado e de biodigestor, até a dose 8 Mg ha-1, assim como o calcário na dose 2 Mg ha-1, não trazem problemas de disponibilidade ao ambiente, com relação aos metais pesados Cd, Cr, Hg, Pb, Ni e As, quando aplicados sobre a superfície em Latossolo Vermelho distrófico, no sistema plantio direto. A fitodisponibilidade de metais pesados às culturas da soja e aveia-preta foi nula, quando foram aplicadas doses de até 8 Mg ha-1 de lodo de esgoto, escória e lama cal sobre a superfície do solo, no sistema plantio direto

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The occurrence of urolithiasis in pregnancy represents a challenge in both diagnosis and treatment of this condition, because it presents risks not only to the mother but also to the fetus. Surgical treatment may be indicated for patients with infection, persistent pain, and obstruction of a solitary kidney. We present our experience on the management of pregnant patients with ureteral calculi and a review of the literature. Materials and Methods: The charts of 19 pregnant patients with obstructive ureteral calculi were retrospectively reviewed. Gestational age ranged from 13 to 33 weeks. In all patients, ureteral stone was diagnosed on abdominal ultrasound. In regard to localization, 15 calculi were in the distal ureter, 3 in the proximal ureter, and 1 in the interior of an ureterocele. Calculi size ranged from 6 to 10 mm (mean, 8 mm). The following criteria were used to indicate ureteroscopy: persistent pain with no improvement after clinical treatment, increase in renal dilation, or presence of uterine contractions. Nine patients (47.3%) were submitted to ureteroscopy. All calculi (100%) were removed with a stone basket extractor under continuous endoscopic vision. None of the calculi demanded the use of a lithotriptor. Results: Nine patients (47.3%) treated with clinical measurements presented no obstetric complications and spontaneous elimination of the calculi. Nine patients (47.3%) submitted to ureteroscopy had no surgical complications. There was remission of pain in all cases after ureteroscopy and ureteral catheter placement. Conclusion: The diagnosis and treatment of ureteral lithiasis in pregnant women present potential risks for the fetus and the mother. Conservative management is the first option, but ureteroscopy may be performed with safety and high success rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Citrus canker is a serious disease caused by Xanthomonas citri subsp. citri bacteria, which infects citrus plants (Citrus spp.) leading to large economic losses in citrus production worldwide. In this work, laser induced fluorescence spectroscopy (LIF) was investigated as a diagnostic technique for citrus canker disease in citrus trees at an orchard using a portable optical fiber based spectrometer. For comparison we have applied LIF to leaves contaminated with citrus canker, citrus scab, citrus variegates chlorosis, and Huanglongbing (HLB, Greening). In order to reduce the noise in the data, we collected spectra from ten leaves with visual symptoms of diseases and from five healthy leaves per plant. This procedure is carried out in order to minimize the environmental effect on the spectrum (water and nutrient supply) of each plant. Our results show that this method presents a high sensitivity (similar to 90%), however it does present a low specificity (similar to 70%) for citrus canker diagnostic. We believe that such poor performance is due to the fact that the optical fiber collects light from only a small part of the leaf. Such results may be improved using the fluorescence imaging technique on the whole leaf. (C) 2010 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct borohydride fuel cells are promising high energy density portable generators. However, their development remains limited by the complexity of the anodic reaction: The borohydride oxidation reaction (BOR) kinetics is slow and occurs at high overvoltages, while it may compete with the heterogeneous hydrolysis of BH(4)(-). Nevertheless, one usually admits that gold is rather inactive toward the heterogeneous hydrolysis of BH(4)(-) and presents some activity regarding the BOR, therefore yielding to the complete eight-electron BOR. In the present paper, by coupling online mass spectrometry to electrochemistry, we in situ monitored the H(2) yield during BOR experiments on sputtered gold electrodes. Our results show non-negligible H(2) generation on Au on the whole BOR potential range (0-0.8 V vs reversible hydrogen electrode), thus revealing that gold cannot be considered as a faradaic-efficient BOR electrocatalyst. We further propose a relevant reaction pathway for the BOR on gold that accounts for these findings.