25 resultados para nasal prosthesis

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the current study was to analyze the effects of rhinoseptoplasty on internal nasal dimensions and speech resonance of individuals with unilateral cleft lip and palate, estimated by acoustic rhinometry and nasometry, respectively. Twenty-one individuals (aged 15-46 years) with previously repaired unilateral cleft lip and palate were analyzed before (PRE), and 6 to 9 (POST1) and 12 to 18 months (POST2) after surgery. Acoustic rhinometry was used to measure the cross-sectional areas (CSAs) of segments corresponding to the nasal valve (CSA1), anterior portion (CSA2), and posterior portion (CSA3) of the lower turbinate, and the volumes at the nasal valve (V1) and turbinate (V2) regions at cleft and noncleft sides, before and after nasal decongestion with a topical vasoconstrictor. Nasometry was used to evaluate speech nasalance during the reading of a set of sentences containing nasal sounds and other devoid of nasal sounds. At the cleft side, before nasal decongestion, there was a significant increase (P < 0.05) in mean CSA1 and V1 values at POST1 and POST2 compared with PRE. After decongestion, increased values were also observed for CSA2 and V2 at POST2. No significant changes were observed at the noncleft side. Mean nasalance values at PRE, POST1, an POST2 were not different from each other in both oral and nasal sentences. The measurement of CSAs and volumes by acoustic rhinometry revealed that rhinoseptoplasty provided, in most cases analyzed, a significant increase in nasal patency, without concomitant changes in speech resonance, as estimated by nasalance assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strategies for the development of new vaccines against Streptococcus pneumoniae infections try to overcome problems such as serotype coverage and high costs, present in currently available vaccines. Formulations based on protein candidates that can induce protection in animal models have been pointed as good alternatives. Among them, the Pneumococcal Surface Protein A (PspA) plays an important role during systemic infection at least in part through the inhibition of complement deposition on the pneumococcal surface, a mechanism of evasion from the immune system. Antigen delivery systems based on live recombinant lactic acid bacteria (LAB) represents a promising strategy for mucosal vaccination, since they are generally regarded as safe bacteria able to elicit both systemic and mucosal immune responses. In this work, the N-terminal region of clade I PspA was constitutively expressed in Lactobacillus casei and the recombinant bacteria was tested as a mucosal vaccine in mice. Nasal immunization with L. casei-PspA 1 induced anti-PspA antibodies that were able to bind to pneumococcal strains carrying both clade 1 and clade 2 PspAs and to induce complement deposition on the surface of the bacteria. In addition, an increase in survival of immunized mice after a systemic challenge with a virulent pneumococcal strain was observed. (C) 2008 Elsevier Masson SAS. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar. A single-camera measuring system was used to record the in-plane deformation on the model surface at a frequency of 1.0 Hz under a load from 0 to 250 N. The images were then analyzed with specialist software to determine the direct (horizontal) and shear strains along the model. Not splinting the crowns resulted in higher stress transfer to the supporting implants when the second molar replica was absent. The presence of a second molar and an effective interproximal contact contributed to lower stress transfer to the supporting structures even for non-splinted restorations. Shear strains were higher in the region between the molars when the second molar was absent, regardless of splinting. The opposite was found for the region between the implants, which had higher shear strain values when the second molar was present. When an effective distal contact is absent, non-splinted implant-supported restorations introduce higher direct strains to the supporting structures under loading. Shear strains appear to be dependent also on the region within the model, with different regions showing different trends in strain changes in the absence of an effective distal contact. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The role of osteocytes in bone structure and function remains partially unresolved. Their participation in mechanotransduction, i.e., the conversion of a physical stimulus into a cellular response, has been hypothesized. The present study was an evaluation of the osteocyte density in the peri-implant bone of immediately loaded and submerged dental implants. Methods: Fourteen male patients were included in the study; all of them were partially edentulous and needed a posterior mandibular restoration. Implants were inserted in these areas; half of the sample was loaded immediately (included in a fixed provisional prosthesis on the same day as implant surgery), whereas the other half was left to heal submerged. Fourteen implants (seven immediately loaded and seven unloaded) were retrieved with a trephine after a healing period of 8 weeks. The specimens were treated to obtain thin ground sections, and histomorphometry was used to evaluate the osteocyte index in the peri-implant bone. Results: A higher and statistically significant number of osteocytes was found in the peri-implant bone around immediately loaded implants (P=0.0081). A correlation between the percentage of bone-implant contact and osteocyte density was found for immediately loaded implants (P=0.0480) but not for submerged implants (P=0.2667). Conclusion: The higher number of osteocytes in the peri-implant bone around immediately loaded implants could be related to the functional adaptation required by the loading stimulus, which also explains the hypothesized involvement of the osteocytes in the maintenance of the bone matrix. J Periodontol 2009;80:499-504.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports a case in which a previous traumatic injury at the age of 2 and pulp necrosis to a primary incisor resulted in a rare injury to the permanent successor tooth. The radiographic examination at the age of 9 showed the arrest of root formation of the permanent maxillary right central incisor, which did not erupt. Tooth 11 was extracted and a functional removable space maintainer was prepared. At the age of 17, the patient received an anterior fixed prosthesis for re-establishment of the esthetics, phonetics and deglutition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. Materials and Methods: A total of 5 male clogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; Astra Tech AB, Molndal, Sweden). Two implants at the extremities of the graft were loaded 2 clays after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 clays later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. Results: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P=.001). The bone-to-implant contact (P=.008) and bone area in a region of interest (P=0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. Conclusions: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Sing 68:825-832, 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-J circle divide rgensen Index) by means of a computerised comparison method. Background: Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Materials and methods: Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-J circle divide rgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. Results: The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Conclusion: Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-J circle divide rgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Self-rating provides a simple direct way of capturing perceptions of health. The objective of this study was to estimate the prevalence and associated factors of poor self-rated oral health among elders. Methods: National data from a cross-sectional population-based study with a multistage random sample of 4786 Brazilian older adults (aged 65-74) in 250 towns were analysed. Data collection included oral examinations (WHO 1997) and struct-ured interviews at elderly households. The outcome was measured by a single five-point-response-scale question dichotomized into `poor` (fair/poor/very poor) and `good` (good/very good) self-rated oral health. Data analyses used Poisson regression models stratified by sex. Results: The prevalence of poor self-rated oral health was 46.6% (95% CI: 45.2-48%) in the whole sample, 50.3% (48-52.5) in men and 44.2% (42.4-46) in women. Higher prevalence ratios (PR) were found in elders reporting unfavourable dental appearance (PR = 2.31; 95% CI: 2.02-2.65), poor chewing ability (PR = 1.64; CI: 1.48-1.8) and dental pain (PR = 1.44; CI: 1.04-1.23) in adjusted analysis. Poor self-perception was also associated with being men, black, unfavourable socioeconomic circumstances, unfavourable clinical oral health and with not using or needing a dental prosthesis. Conclusion: Assessment and understanding of self-rated oral health should take into account social factors, subjective and clinical oral symptoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: We investigated effects of chronic exposure (2 months) to ambient levels of particulate matter (PM) on development of protease-induced emphysema and pulmonary remodeling in mice. Methods: Balb/c mice received nasal drop of either papain or normal saline and were kept in two exposure chambers situated in an area with high traffic density. One of them received ambient air and the other had filters for PM. Results: mean concentration of PM10 was 2.68 +/- 0.38 and 33.86 +/- 2.09 mu g/m(3), respectively, in the filtered and ambient air chambers (p<0.001). After 2 months of exposure, lungs from papain-treated mice kept in the chamber with ambient air presented greater values of mean linear intercept, an increase in density of collagen fibers in alveolar septa and in expression of 8-isoprostane (p = 0.002, p < 0.05 and p = 0.002, respectively, compared to papain-treated mice kept in the chamber with filtered air). We did not observe significant differences between these two groups in density of macrophages and in amount of cells expressing matrix metalloproteinase-12. There were no significant differences in saline-treated mice kept in the two chambers. Conclusions: We conclude that exposure to urban levels of PM worsens protease-induced emphysema and increases pulmonary remodeling. We suggest that an increase in oxidative stress induced by PM exposure influences this response. These pulmonary effects of PM were observed only in mice with emphysema. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we report on 10 male patients with frontonasal dysplasia, cleft lip/palate, mental retardation, lack of language acquisition, and severe central nervous system involvement. Imaging studies disclosed absence of the corpus callosum, midline cysts, and an abnormally modeled cerebellum. Neuronal heterotopias were present in five patients and parieto-occipital encephalocele in three patients. We suggest that this pattern found exclusively in males, most likely represents a newly recognized syndrome distilled from the group of disorders subsumed under frontonasal dysplasia. (C) 2009 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nonsyndromic alar clefts are rare and they range from a small notch to variable size of clefts of the nasal ala. Usually they are restricted to the alar region, but other minor anomalies such as midline nasal sinuses and small midline or ""northbound"" clefts can be present. To date all reported cases of nonsyndromic alar clefts have been sporadic. Here we report on five new cases of isolated and nonsyndromic alar clefts. (C) 2009 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this prospective randomized clinical trial was to compare 2 cohorts of standardized cleft patients with regard to functional speech outcome and the presence or absence of palatal fistulae. The 2 cohorts are randomized to undergo either a conventional von Langenbeck repair with intravelar velarplasty or the double-opposing Z-plasty Furlow procedure. A prospective 2 x 2 x 2 factorial clinical trial was used in which each subject was randomly assigned to 1 of 8 different groups: 1 of 2 different lip repairs (Spina vs. Millard), 1 of 2 different palatal repair (von Langenbeck vs. Furlow), and 1 of 2 different ages at time of palatal surgery (9-12 months vs. 15-18 months). All surgeries were performed by the same 4 surgeons. A cul-de-sac test of hypernasality and a mirror test of nasal air emission were selected as primary outcome measures for velopharyngeal function. Both a surgeon and speech pathologist examined patients for the presence of palatal fistulae. In this study, the Furlow double-opposing Z-palatoplasty resulted in significantly better velopharyngeal function for speech than the von Langenbeck procedure as determined by the perceptual cul-de-sac test of hypernasality. Fistula occurrence was significantly higher for the Furlow procedure than for the von Langenbeck. Fistulas were more likely to occur in patients with wider clefts and when relaxing incisions were not used.