35 resultados para electrolytic tanks
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
In this work we investigate the influence of the adsorption of ions on the impedance spectroscopy of an electrolytic cell. We consider that the positive and negative ions present in a dielectric liquid are adsorbed in the electrode surfaces with different adsorption energies. This difference in adsorption energies causes an additional plateaux in the limit of the low-frequency range of the real part of the impedance Z. In the same frequency range, a second minimum in the imaginary part of Z is predicted. The theory is illustrated with measurements of the impedance of an electrolytic solution in the frequency range from 10(-2) Hz to 1 KHz. A comparison between the present model and others from the literature to describe the experimental results is also made.
Resumo:
This study investigated the representativeness of samples for assessing chemical elements in milk bulk tanks. Milk samples were collected from a closed tank in a dairy plant and from an open top tank in a dairy farm. Samples were analyzed for chemical elements by instrumental neutron activation analysis (INAA). For both experiments, Br, Ca, Cs, K, Na, Rb and Zn did not present significant differences between samples thereby indicating the appropriateness of the sampling procedure adopted to evaluate the analytes of interest.
Resumo:
The analysis of the electrical impedance of an electrolytic cell in the shape of a slab is performed. We have solved, numerically, the differential equations governing the phenomenon of the redistribution of the ions in the presence of an external electric field, and compared the results with the ones obtained by solving the linear approximation of these equations. The control parameters in our study are the amplitude and the frequency of the applied voltage, assumed a simple harmonic function of the time. We show that for the large amplitudes of the applied voltage, the actual current is no longer harmonic at low frequencies. From this result it follows that the concept of electrical impedance of a cell is a useful quantity only in the case where the linear approximation of the fundamental equations of problem work well.
Resumo:
We analyze the influence of a surface dielectric layer on the transient phenomena related to the ionic redistribution in an electrolytic cell submitted to a step-like external voltage. The adsorption-desorption phenomenon is taken into account in the famework of the Gouy-Chapman approximation, where the ions are assumed dimensionless. In the limit of small amplitude of the applied voltage, where the equations of the problem can be linearized, we obtain an analytical solution for the surface densities of ions, for the electrical potential and for the relaxation time for the transient phenomena. In the general case, when the linearized analysis is no longer valid, the solution of the problem is obtained numerically. The role of the thickness of the dielectric layer on the relaxation time is also discussed.
Resumo:
Neste trabalho, avaliou-se a adição de células íntegras de levedura e seus derivados em dietas para juvenis de tilápia do Nilo. Foram utilizados 144 juvenis machos de tilápia (peso médio de 52,1g) distribuídos em 12 tanques de fibra de vidro (250L), em delineamento inteiramente casualizado, composto por quatro tratamentos e três repetições. Os peixes foram alimentados ad libitum, duas vezes ao dia durante 60 dias, com dietas isoproteicas (28% PB) e isocalóricas (2.900kcal de ED kg-1) contendo levedura íntegra de cana-de-açúcar (LI), levedura autolisada (LA) e parede celular (PC) adicionados na proporção de 25% da proteína bruta total, comparadas com uma dieta controle (CO), sem adição de levedura. Não foram observadas diferenças significativas para conversão alimentar aparente e taxa de eficiência protéica. No entanto, o ganho em peso foi melhor nos peixes alimentados com as dietas LA (114,70g) e PC (131,03g), assim como em relação à taxa de crescimento específico (LA=1,79 e PC=1,93%), à proteína bruta no ganho de peso (LA=14,45 e PC=15,62%) e ao conteúdo corporal proteico (LA=14,89 e PC=15,67g 100g-1). As frações, a parede celular e a levedura autolisada de cana-de-açúcar podem ser utilizadas em dietas para juvenis de tilápia.
Resumo:
Avaliaram-se os efeitos da inclusão de farelo de canola em dietas de juvenis de pacu (Piaractus mesopotamicus) sobre parâmetros de crescimento e composição corporal. Um total de 192 alevinos (9 a 15g) foram estocados em 24 tanques de cimento, de 100l de capacidade, durante 103 dias. O farelo de canola foi utilizado em quatro proporções: zero; 9,5%; 19% e 38% da dieta, com ou sem farinha de peixe (12%/dieta), totalizando oito tratamentos. A presença de farinha de peixe não afetou os parâmetros de crescimento avaliados. A inclusão de 38% de farelo de canola na dieta diminuiu o ganho de peso dos peixes, valores médios de 28,74g a 50,70g, e piorou a conversão alimentar aparente, de 1,66 para 2,85. A taxa de eficiência protéica também foi menor nos peixes alimentados com 38% de farelo de canola. As várias proporções de farelo de canola das dietas alteraram os teores de umidade, proteína bruta e lipídios dos peixes. A presença da farinha de peixe, nas dietas, somente influiu no teor de lipídios dos peixes alimentados com dietas contendo 9,5% de farelo de canola. Conclui-se que até 19% de farelo de canola pode ser adicionado às dietas de juvenis de pacu, sem que seu desenvolvimento seja prejudicado.
Resumo:
Investigou-se o efeito da adição de C18:2n6, por meio da inclusão de óleo de milho em dietas com dois níveis de proteína bruta, sobre o processo de maturação de gametas de pintado, Pseudoplatystoma corruscans, mantidos em tanques-rede. Foram avaliados: taxa de sobrevivência, relação peso x comprimento, fator de condição (K) e índice gonadossomático (IGS). O experimento foi realizado entre março de 2004 e fevereiro de 2006, em 12 tanques-rede, distribuídos em seis viveiros-escavados de 600m² e densidade de estocagem de 20 peixes/tanque-rede. Utilizaram-se três tratamentos (T) com duas repetições/viveiro: T1 com 28% de PB; T2 com 28% de PB + 5% óleo de milho e T3 com 40% de PB. O crescimento foi ligeiramente mais alto nos peixes do T3. As taxas de sobrevivência foram acima de 77%. Pode-se inferir que as rações ofertadas não causaram alterações histomorfológicas durante o processo de maturação gonadal dessa espécie. O IGS e o K foram ligeiramente mais altos nos animais alimentados com a ração enriquecida com óleo de milho.
Resumo:
OBJETIVO: Comparar a diversidade da fauna de culicídeos em bromélias de solo segundo ambientes urbano, periurbano e mata primitiva. MÉTODOS: O estudo foi realizado no município de Ilhabela, litoral norte do estado de São Paulo, em tanques de bromélias de ambientes urbano, periurbano e mata. Realizaram-se coletas de imaturos quinzenalmente, de março de 1998 a julho de 1999. A presença e freqüência de espécies nos diferentes ambientes foram comparadas com base em estimativas da diversidade para medir a riqueza, dominância e análise de variância (ANOVA). RESULTADOS: Coletaram-se 31.134 formas imaturas de mosquitos nas bromélias, distribuídas em sete gêneros e 37 espécies. O ambiente urbano registrou maior abundância, 14.575 indivíduos, seguido do periurbano com 10.987, e a mata, com o menor número de exemplares, 5.572. Foram coletadas 30 espécies no habitat urbano, 32 no periurbano e 33 na mata. As espécies dominantes foram Culex (Microculex) pleuristriatus nos ambientes urbano e periurbano, e Culex ocellatus na mata. De acordo com teste ANOVA a freqüência de mosquitos em bromélias não foi diferente entre os ambientes pesquisados (F=0,5564; p=0,5769). A diversidade de espécies na mata foi maior, e semelhante entre periurbano e urbano. CONCLUSÕES: A composição específica de culicídeos em bromélias de solo mostrou-se diversificada, sendo maior naquelas de ambiente de mata. As espécies dominantes foram Cx. (Mcx.) pleuristriatus e Cx. ocellatus.
Resumo:
The objective of this paper was to assess bacteriological quality of drinking water in a peri-urban area located in the Metropolitan Region of São Paulo, Brazil. A total of 89 water samples were collected from community plastic tanks and 177 water samples from wells were collected bimonthly, from September 2007 to November 2008, for evaluating bacteriological parameters including: Escherichia coli, Enterococcus and heterotrophic plate count (HPC). Clostridium perfringens was investigated in a subsample (40 samples from community plastic tank and 40 from wells). E. coli was present in 5 (5.6%) samples from community plastic tanks (2.0 - 5.1x10(4) MPN/100mL) and in 70 (39.5%) well samples (2.0 - 8.6x10(4) MPN/100mL). Thus, these samples were not in accordance with the Brazilian Regulation. Enterococcus was detected in 20 (22.5%) samples of the community plastic tanks (1 to 79 NC/100mL) and in 142 (80.2%) well samples (1 to >200 NC/100mL). C. perfringens was detected in 5 (12.5%) community plastic tanks samples and in 35 (87.5%) wells samples (2.2 to >16 MPN/100mL). HPC were above 500 CFU/mL in 5 (5.6%) waters from community plastic tanks. In wells samples, the HPC ranged from <1 to 1.6x10(4) CFU/mL. The residual chlorine did not attend the standard established in the drinking water legislation (0.2 mg/L), except in 20 (22.5%) samples. These results confirm the vulnerability of the water supply systems in this peri-urban area what is clearly a public health concern.
Resumo:
The analysis of Macdonald for electrolytes is generalized to the case in which two groups of ions are present. We assume that the electrolyte can be considered as a dispersion of ions in a dielectric liquid, and that the ionic recombination can be neglected. We present the differential equations governing the ionic redistribution when the liquid is subjected to an external electric field, describing the simultaneous diffusion of the two groups of ions in the presence of their own space charge fields. We investigate the influence of the ions on the impedance spectroscopy of an electrolytic cell. In the analysis, we assume that each group of ions have equal mobility, the electrodes perfectly block and that the adsorption phenomena can be neglected. In this framework, it is shown that the real part of the electrical impedance of the cell has a frequency dependence presenting two plateaux, related to a type of ambipolar and free diffusion coefficients. The importance of the considered problem on the ionic characterization performed by means of the impedance spectroscopy technique was discussed. (c) 2008 American Institute of Physics.
Resumo:
The electrodeposition of nickel based composites is been performed in order to improve properties of nickel layers, such as hardness, wear resistance, lubrication, corrosion resistance and catalytic activity. In the present work Nb powders (20 mu m average size) and Ni were codeposited on 1020 carbon steel by galvanostatic electrolysis of Watts bath, using 10, 20 and 40 mA/cm(2) cathodic current density and 240, 400 and 550 rpm electrolyte stirring rate. The morphology and texture of the coatings, Nb incorporated volume fraction, microhardness, adhesion to the substrate and corrosion behavior were evaluated. The Ni-Nb composite layers presented a rough morphology with randomly oriented Ni grains, whereas pure Ni coatings were smooth and showed highly preferred orientation in the [110] or [100] direction. The volume fraction of Nb in the composites determined by image analysis ranged from 8.5 to 19%. The 400 rpm stirring rate led to the highest Nb content (16 to 19016) for all current densities investigated The microhardness of the composite layers was higher than that of pure Ni coatings due to refining of Ni grains induced by incoporation of Nb particles. The adhesion of the coatings estimated qualitatively by bend test was found satisfactory. The Ni-Nb composites presented lower corrosion rate than Ni coatings in both 3% NaCl and 20% H2SO4 solutions.
Resumo:
Silicon nitride particles were incorporated to electrolytic copper by co-electrodeposition in acidic sulfate bath, aiming the improvement of its mechanical resistance. Smooth deposits containing well-distributed silicon nitride particles were obtained. The current density did not show significant influence on incorporated particle volume fraction, whereas the variation of particle concentration in the bath had a more pronounced effect. The microhardness of the composite layers was higher than that of pure copper deposits obtained under the same conditions and increased with the increase of incorporated particle volume fraction. The microhardness of composites also increased with the increase of current density due to copper matrix grain refining. The composite coatings were slightly more corrosion resistant than pure copper deposits in 3.5% NaCl solutions.
Resumo:
There are about 7500 water treatment plants in Brazil. The wastes these plants generate in their decantation tanks and filters are discharged directly into the same brooks and rivers that supply water for treatment. Another serious environmental problem is the unregulated disposal of construction and demolition rubble, which increases the expenditure of public resources by degrading the urban environment and contributing to aggravate flooding and the proliferation of vectors harmful to public health. In this study, an evaluation was made of the possibility of recycling water treatment sludge in construction and demolition waste recycling plants. The axial compressive strength and water absorption of concretes and mortars produced with the exclusive and joint addition of these two types of waste was also determined. The ecoefficiency of this recycling was evaluated by determining the concentration of aluminum in the leached extract resulting from the solubilization of the recycled products. The production of concretes and mortars with the joint addition of water treatment sludge and recycled concrete rubble aggregates proved to be a viable recycling alternative from the standpoint of axial compression strength, modulus of elasticity, water absorption and tensile strength by the Brazilian test method. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
This paper compares the critical impeller speed results for 6 L Denver and Wemco bench-scale flotation cells with findings from a study by Van der Westhuizen and Deglon [Van der Westhuizen, A.P., Deglon, D.A., 2007. Evaluation of solids suspension in a pilot-scale mechanical flotation cell: the critical impeller speed. Minerals Engineering 20,233-240; Van der Westhuizen, A.P., Deglon, D.A., 2008. Solids suspension in a pilot scale mechanical flotation cell: a critical impeller speed correlation. Minerals Engineering 21, 621-629] conducted in a 125 L Batequip flotation cell. Understanding solids suspension has become increasingly important due to dramatic increases in flotation cell sizes. The critical impeller speed is commonly used to indicate the effectiveness of solids suspension. The minerals used in this study were apatite, quartz and hematite. The critical impeller speed was found to be strongly dependent on particle size, solids density and air flow rate, with solids concentration having a lesser influence. Liquid viscosity was found to have a negligible effect. The general Zwietering-type critical impeller speed correlation developed by Van der Westhuizen and Deglon [Van der Westhuizen, A.P., Deglon, D.A., 2008. Solids suspension in a pilot scale mechanical flotation cell: a critical impeller speed correlation. Minerals Engineering 21, 621-629] was found to be applicable to all three flotation machines. The exponents for particle size, solids concentration and liquid viscosity were equivalent for all three cells. The exponent for solids density was found to be less significant than that obtained by the previous authors, and to be consistent with values reported in the general literature for stirred tanks. Finally, a new dimensionless critical impeller speed correlation is proposed where the particle size is divided by the impeller diameter. This modified equation generally predicts the experimental measurements well, with most predictions within 10% of the experimental. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Effective solids suspension is a necessary precondition for particle collection, and solids suspension is largely dependent on the hydrodynamics of the flotation cell. This study attempted to correlate the status of the suspension of apatite particles of different sizes in a Denver laboratory flotation cell versus the impeller rotational speed (N) adopted to operate the machine. The latter variable (N) influences the impeller capacity to lift the particles from the bottom of the tank and also to disperse them throughout the volume of the vessel. Such an impeller capacity can be characterized by the critical impeller speed for the accomplishment of solids off-bottom suspension (N(z)) and also by the velocity of the radial water flow discharged by the impeller (U) divided by the particle terminal settling velocity (U(s)). This way, the status of the suspension of apatite particles inside the flotation cell can be characterized by one of three categories: ""segregation"" (N/N(2) < 0.60 and U(s)/U > 0.08); ""suspension"" (0.60 <= N/N(2) < 1 and 0.06 < U(s)/U < 0.10); and ""dragging"" (N/N(2) >= 1 and U(s)/U <= 0.03). The range of impeller rotational speed (N), which was able to suspend the finest particles (D(p) = 90,mu m), was unable to suspend the coarsest particles (D(P) = 254 mu m). Conversely, the high value of N (N > 1,300 rpm), which is adequate to suspend the coarsest particles, may promote the entrainment of the finest particles to the froth layer.