35 resultados para VISUAL INSPECTION
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen`s kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. On the other hand, radiographic examination and laser fluorescence were less efficient when used alone.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.
Caracterização de feições oceanográficas na plataforma de Santa Catarina através de imagens orbitais
Resumo:
Este trabalho tem por objetivo identificar e caracterizar as feições oceanográficas de pequena e mesoescala que ocorrem na plataforma continental de Santa Catarina (SC). Foram empregadas imagens de temperatura e concentração de clorofila da superfície do mar (TSM e CSM), obtidas pelo sensor MODIS. Foi selecionada uma imagem diária para cada mês do ano de 2003, excetuando dezembro, onde procurou-se avaliar efeitos sazonais. As feições oceanográficas foram observadas através da aplicação de diferentes níveis de contraste e paletas de cores para realce. Foram identificadas feições como vórtices, meandros, cogumelos, plumas, filamentos, frentes e áreas de ressurgências. Os resultados indicam que no verão a distribuição superficial em mesoescala da temperatura é mais homogênea, levando a um número menor de feições observáveis. O fenômeno de ressurgência costeira em escala localizada ao sul da Ilha de SC e junto à costa foi observado nos meses de novembro, janeiro e fevereiro. Durante o outono e o inverno as imagens apresentaram maior grau de complexidade, principalmente devido à presença da frente costeira do Prata, com características de menor temperatura e maiores valores de clorofila.
Resumo:
The citrus greening (or huanglongbing) disease has caused serious problems in citrus crops around the world. An early diagnostic method to detect this malady is needed due to the rapid dissemination of Candidatus Liberibacter asiaticus (CLas) in the field. This analytical study investigated the fluorescence responses of leaves from healthy citrus plants and those inoculated with CLas by images from a stereomicroscope and also evaluated their potential for the early diagnosis of the infection caused by this bacterium. The plants were measured monthly, and the evolution of the bacteria on inoculated plants was monitored by real-time quantitative polymerase chain reaction (RT-qPCR) amplification of CLas sequences. A statistical method was used to analyse the data. The selection of variables from histograms of colours (colourgrams) of the images was optimized using a paired Student's t-test. The intensity of counts for green colours from images of fluorescence had clearly minor variations for healthy plants than diseased ones. The darker green colours were the indicators of healthy plants and the light colours for the diseased. The method of fluorescence images is novel for fingerprinting healthy and diseased plants and provides an alternative to the current method represented by PCR and visual inspection. A new, non-subjective pattern of analysis and a non-destructive method has been introduced that can minimize the time and costs of analyses.
Resumo:
In this study we analyzed the topography of induced cortical oscillations in 20 healthy individuals performing simple attention tasks. We were interested in qualitatively replicating our recent findings on the localization of attention-induced beta bands during a visual task [1], and verifying whether significant topographic changes would follow the change of attention to the auditory modality. We computed corrected latency averaging of each induced frequency bands, and modeled their generators by current density reconstruction with Lp-norm minimization. We quantified topographic similarity between conditions by an analysis of correlations, whereas the inter-modality significant differences in attention correlates were illustrated in each individual case. We replicated the qualitative result of highly idiosyncratic topography of attention-related activity to individuals, manifested both in the beta bands, and previously studied slow potential distributions [2]. Visual inspection of both scalp potentials and distribution of cortical currents showed minor changes in attention-related bands with respect to modality, as compared to the theta and delta bands, known to be major contributors to the sensory-related potentials. Quantitative results agreed with visual inspection, supporting to the conclusion that attention-related activity does not change much between modalities, and whatever individual changes do occur, they are not systematic in cortical localization across subjects. We discuss our results, combined with results from other studies that present individual data, with respect to the function of cortical association areas.
Resumo:
We have developed a new procedure to search for carbon-enhanced metal-poor (CEMP) stars from the Hamburg/ESO (HES) prism-survey plates. This method employs an extended line index for the CH G band, which we demonstrate to have superior performance when compared to the narrower G-band index formerly employed to estimate G-band strengths for these spectra. Although CEMP stars have been found previously among candidate metal-poor stars selected from the HES, the selection on metallicity undersamples the population of intermediate-metallicity CEMP stars (-2.5 <= [Fe/H] <= -1.0); such stars are of importance for constraining the onset of the s-process in metal-deficient asymptotic giant branch stars (thought to be associated with the origin of carbon for roughly 80% of CEMP stars). The new candidates also include substantial numbers of warmer carbon-enhanced stars, which were missed in previous HES searches for carbon stars due to selection criteria that emphasized cooler stars. A first subsample, biased toward brighter stars (B < 15.5), has been extracted from the scanned HES plates. After visual inspection (to eliminate spectra compromised by plate defects, overlapping spectra, etc., and to carry out rough spectral classifications), a list of 669 previously unidentified candidate CEMP stars was compiled. Follow-up spectroscopy for a pilot sample of 132 candidates was obtained with the Goodman spectrograph on the SOAR 4.1 m telescope. Our results show that most of the observed stars lie in the targeted metallicity range, and possess prominent carbon absorption features at 4300 angstrom. The success rate for the identification of new CEMP stars is 43% (13 out of 30) for [Fe/H] < -2.0. For stars with [Fe/H] < -2.5, the ratio increases to 80% (four out of five objects), including one star with [Fe/H] < -3.0.
Resumo:
The premature failure of steam turbine rotor blades, manufactured in forged 12% Cr-NiMoV martensitic stainless steel, was investigated using visual inspection non-destructive testing, macro and microfractography, microstructural characterization, EDS microanalysis, chemical analysis, micro hardness and tensile testing. The blades belonged to the last stage of a thermoelectric plant steam turbine generator (140 MV A). The results indicated that the failure of the blades was promoted by foreign-particle erosion, which attacked preferentially the low-pressure side of the lower trailing edge of the blades. The resulting wear grooves acted as stress raisers and promoted the nucleation of fatigue cracks, which probably grew during the transition events of the steam turbine operation. Finally, water drop erosion was observed on the blade upper leading edge (low-pressure side). (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This study was the first conducted in Brazil to evaluate the presence of Enterobacter sakazakii in milk-based powdered infant formula manufactured for infants 0 to 6 months of age and to examine the conditions of formula preparation and service in three hospitals in Sao Paulo State, Brazil. Samples of dried and rehydrated infant formula, environments of milk kitchens, water, bottles and nipples, utensils, and hands of personnel were analyzed, and E. sakazakii and Enterobacteriaceae populations were determined. All samples of powdered infant formula purchased at retail contained E. sakazakii at <0.03 most probable number (MPN)/100 g. In hospital samples, E. sakazakii was found in one unopened formula can (0.3 MPN/100 g) and in the residue from one nursing bottle from hospital A. All other cans of formula from the same lot bought at a retail store contained E. sakazakii at <0.03 MPN/100 g. The pathogen also was found in one cleaning sponge from hospital B. Enterobacteriaceae populations ranged from 10(1) to 10(5) CFU/g in cleaning aids and <5 CFU/g in all formula types (dry or rehydrated), except for the sample that contained E. sakazakii, which also was contaminated with Enterobacteriaceae at 5 CFU/g. E. sakazakii isolates were not genetically related. In an experiment in which rehydrated formula was used as the growth medium, the temperature was that of the neonatal intensive care unit (25 C), and the incubation time was the average time that formula is left at room temperature while feeding the babies (up to 4 h), a 2-log increase in levels of E. sakazakii was found in the formula. Visual inspection of the facilities revealed that the hygienic conditions in the milk kitchens needed improvement. The length of time that formula is left at room temperature in the different hospitals while the babies in the neonatal intensive care unit are being fed (up to 4 h) may allow for the multiplication of E. sakazakii and thus may lead to an increased health risk for infants.
Resumo:
Aims: To evaluate the role of hormonal contraceptives as a risk factor of high-risk human papillomavirus (HR-HPV), cervical intraepithelial lesions (CIN) and cervical cancer in our multi-center population-based LAMS (Latin American Screening) study. Methods: A cohort study with >12,000 women from Brazil and Argentina using logistic regression to analyze the covariates of hormonal contraception (HOC - oral, injections, patches, implants, vaginal ring and progesterone intrauterine system) use followed by multivariate modeling for predictors of HR-HPV and CIN2+. Results: HR-HPV infection was a consistent risk factor of high-grade CIN in all three groups of women. The length of HOC use was not significantly related to high-grade squamous intraepithelial lesions (HSIL)+ Pap (p = 0.069), LSIL+ Pap (p = 0.781) or ASCUS+ (p = 0.231). The same was true with the length of HOC use and histology CIN3+ (p = 0.115) and CIN2+ (p = 0.515). Frequently, HOC users have previously shown more HPV-related lesions, as well as lower HPV prevalence if they were current smokers. But HOC use and time of usage were not independent risk factors of either HR-HPV infection or high-grade CIN using multiple logistic regressions. Conclusions: No evidence was found for an association between the use of HOC with an increased risk for HR-HPV infection or high-grade CIN in this cohort. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
The integration of nanostructured films containing biomolecules and silicon-based technologies is a promising direction for reaching miniaturized biosensors that exhibit high sensitivity and selectivity. A challenge, however, is to avoid cross talk among sensing units in an array with multiple sensors located on a small area. In this letter, we describe an array of 16 sensing units, of a light-addressable potentiometric sensor (LAPS), which was made with layer-by-Layer (LbL) films of a poly(amidomine) dendrimer (PAMAM) and single-walled carbon nanotubes (SWNTs), coated with a layer of the enzyme penicillinase. A visual inspection of the data from constant-current measurements with liquid samples containing distinct concentrations of penicillin, glucose, or a buffer indicated a possible cross talk between units that contained penicillinase and those that did not. With the use of multidimensional data projection techniques, normally employed in information Visualization methods, we managed to distinguish the results from the modified LAPS, even in cases where the units were adjacent to each other. Furthermore, the plots generated with the interactive document map (IDMAP) projection technique enabled the distinction of the different concentrations of penicillin, from 5 mmol L(-1) down to 0.5 mmol L(-1). Data visualization also confirmed the enhanced performance of the sensing units containing carbon nanotubes, consistent with the analysis of results for LAPS sensors. The use of visual analytics, as with projection methods, may be essential to handle a large amount of data generated in multiple sensor arrays to achieve high performance in miniaturized systems.
Resumo:
Citrus canker is a serious disease caused by Xanthomonas citri subsp. citri bacteria, which infects citrus plants (Citrus spp.) leading to a large economic loss in citrus production worldwide. In Brazil citrus canker control is done by an official eradication campaign, therefore early detection of such disease is important to prevent greater economic losses. However, detection is difficult and so far it has been done by visual inspection of each tree. Suspicious leaves from citrus plants in the field are sent to the laboratory to confirm the infection by laboratory analysis, which is a time consuming. Our goal was to develop a new optical technique to detect and diagnose citrus canker in citrus plants with a portable field spectrometer unit. In this paper, we review two experiments on laser induced fluorescence spectroscopy (LIF) applied to detect citrus canker. We also present new data to show that the length of time a leaf has been detached is an important variable in our studies. Our results show that LIF has the potential to be applied to citrus plants.
Resumo:
A redução da disponibilidade de espécies de madeiras nativas e seus efeitos na economia, associada ao fortalecimento dos conceitos de preservação ambiental, criou a necessidade de desenvolvimento de alternativas viáveis para utilização racional de espécies de reflorestamento. E uma das opções é a realização de classificação visual das peças. Autores de trabalhos desenvolvidos nessa linha de pesquisa verificaram a adequação das regras de classificação visual do Southern Pine Inspection Bureau (SPIB) dos EUA à madeira de Pinus do Brasil e apresentaram proposta para normalizar o processo de classificação visual dessa madeira. Nessa classificação, os aspectos com maior influência são: presença de nós, desvio de grã em relação ao eixo da peça e densidade de anéis de crescimento. Assim, esta pesquisa apresenta um estudo experimental que consistiu na classificação visual e determinação da resistência à tração de 85 peças de Pinus spp e um estudo teórico, que propôs uma equação para determinar a resistência à tração média de peças estruturais em função da classificação visual. Com este trabalho, foi possível observar a influência dos nós e dos anéis de crescimento sobre a resistência à tração das peças analisadas.
Resumo:
A avaliação da dor em animais necessita da utilização de escalas de avaliação, que dependem da interpretação realizada por observadores. O objetivo do presente estudo foi avaliar a correlação entre a escala visual analógica (EVA), escala de Melbourne e os filamentos de Von Frey, na avaliação da dor pós-operatória em 42 cadelas adultas e saudáveis, submetidas à ovariossalpingohisterectomia (OSH). A dor pós-operatória foi avaliada por dois observadores cegos aos tratamentos analgésicos, em intervalos de uma hora, utilizando a EVA, a escala de Melbourne e os filamentos de Von Frey, aplicados ao redor da incisão cirúrgica. Foram considerados como critérios para realização da analgesia resgate uma pontuação de 50mm na EVA ou de 13 pontos na escala de Melbourne. A EVA revelou-se a escala mais sensível, uma vez que 100% dos animais receberam resgate seguindo esse método. Os valores obtidos na EVA e na escala de Melbourne determinaram boa correlação, com r=0,74, o que não ocorreu com os filamentos de Von Frey (r=-0,18). Já a correlação entre a escala de Melbourne e os filamentos de Von Frey foi de -0.37. Apesar de a EVA e a escala de Melbourne apresentarem boa correlação, sugere-se que se considere uma pontuação menor na escala de Melbourne como critério para administração de analgesia resgate.