4 resultados para Urban system

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pinheiros River (Brazil) plays a pivotal role in supplying water to Billings Reservoir, which presents multiple uses (human drinking, energy generation, irrigation, navigation, fishing and leisure) An intense monitoring program was performed during the years 2007 and 2008 to find out whether on site flotation is a feasible solution or not for improving the water quality of this urban river, attenuating the pollutants load caused by the water pumping to the reservoir (approximately 10 m(3)s(-1)) The monitoring of 18 variables (13,429 laboratorial analysis during the period of 490 days), suggested that despite the convenience of the on site approach for water treatment, especially for rivers located in fully urbanized areas, the flotation system is not enough itself to recover Pinheiros River water quality, given the several constraints that apply Total phosphorus removal was high in percentage terms (about 90%), although the remaining concentrations were not so low (mean of 0 05 mg L(-1)) The removal efficiency of some variables was insufficient, leading to high final mean concentrations of metals [e g aluminium (0 29 mg L(-1)), chromium (0 02 mg L(-1)) and iron (1 1 mg L(-1))] as well as nitrogen-ammonia (25 8 mg L(-1)) and total suspended solids (18 mg L(-1)) in the treated water

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Mycobacterium tuberculosis genotypes resistant to reactive nitrogen intermediates (RNI) predominate in certain urban communities, suggesting that this phenotype influences disease transmission. OBJECTIVE: To compare different M. tuberculosis genotypes for resistance to RNI generated in vitro. DESIGN: We genotyped 420 M. tuberculosis isolates from a neighborhood in Sao Paulo, Brazil, and analyzed them for susceptibility to RNI generated in acidified sodium nitrite (ASN) solution. RESULTS: Seventy-one (43%) of 167 recent-infection strains and 68 (43%) of 158 endogenous infection strains showed moderate- to high-level ASN resistance. CONCLUSION: ASN resistance of M. tuberculosis is not necessarily a determining factor for enhanced transmission.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We developed an analytical method and constrained procedural boundary conditions that enable accurate and precise Zn isotope ratio measurements in urban aerosols. We also demonstrate the potential of this new isotope system for air pollutant source tracing. The procedural blank is around 5 ng and significantly lower than published methods due to a tailored ion chromatographic separation. Accurate mass bias correction using external correction with Cu is limited to Zn sample content of approximately 50 ng due to the combined effect of blank contribution of Cu and Zn from the ion exchange procedure and the need to maintain a Cu/Zn ratio of approximately 1. Mass bias is corrected for by applying the common analyte internal standardization method approach. Comparison with other mass bias correction methods demonstrates the accuracy of the method. The average precision of delta(66)Zn determinations in aerosols is around 0.05% per atomic mass unit. The method was tested on aerosols collected in Sin Paulo City, Brazil. The measurements reveal significant variations in delta(66)Zn(Imperial) ranging between -0.96 and -0.37% in coarse and between -1.04 and 0.02% in fine particular matter. This variability suggests that Zn isotopic compositions distinguish atmospheric sources. The isotopic light signature suggests traffic as the main source. We present further delta(66)Zn(Imperial) data for the standard reference material NIST SRM 2783 (delta 66Z(Imperial) = 0.26 +/- 0.10%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An exploratory investigation was conducted on the effects of application of ozone on the removal of organic and inorganic contaminants and the reduction of settleable solids in urban lake sediments. Homogenized sediment samples were treated in a batch reactor with an external recirculation loop and ozone feed from a Venturi injector. The ozone generating system was fed with ambient air with small footprint and operational simplicity. Ozone mass application (g/h) and contact time (min) were varied over wide ranges during testing. The effects of the ozone mass applied per unit time and the contact time on contaminant removal efficiencies were analyzed and a trade-off between the costs of ozonation and of solids treatment and disposal was proposed. The minimum ozone mass application required for total contaminant removal apparently depended on the type of organic contaminant present. An apparent influence of inorganic contaminant speciation on the removal efficiency was found and discussed.