112 resultados para Silicone ventricle

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The `biomimetic` approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD`s inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber, variable throttle and reservoir, connected by silicone tubings. The reservoir sat on an elevated platform, allowing adjustment of ventricular preload between 0 and 11 mmHg. To allow for sterile gaseous exchange between the circuit interior and exterior, a 0.2 mu m filter was placed at the reservoir. Pressure and flow were registered downstream of the TE valve. The circuit was filled with culture medium and fitted in a standard 5% CO(2) incubator set at 37 degrees C. Pressure and flow waveforms were similar to those obtained under physiological conditions for the pulmonary circulation. The `cardiomimetic` approach presented here represents a new perspective to conventional biomimetic approaches in TE, with potential advantages. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Memantine is an N-methyl-d-aspartate (NMDA) glutamate receptor antagonist used to treat Alzheimer's disease. Previous studies have suggested that receptor blockers act as neuroprotective agents; however, no study has specifically investigated the impact that these drugs have on the heart. We sought to evaluate the effects of memantine on nuclear size reduction in cardiac cells exposed to cold stress. METHOD: We used male EPM-Wistar rats (n=40) divided into 4 groups: 1) Matched control (CON); 2) Memantine-treated rats (MEM); 3) Rats undergoing induced hypothermia (IH) and 4) Rats undergoing induced hypothermia that were also treated with memantine (IHM). Animals in the MEM and IHM groups were treated by oral gavage administration of 20 mg/kg/day memantine over an eight-day period. Animals in the IH and IHM groups were submitted to 4 hours of hypothermia in a controlled environment with a temperature of - 8ºC on the last day of the study. RESULTS: The MEM group had the largest cardiomyocyte nuclear size (151 ± 3.5 μm³ vs. CON: 142 ± 2.3 μm³; p<0.05), while the IH group had the smallest mean value of nuclear size. The nuclear size of the IHM group was preserved (125 ± 2.9 μm³) compared to the IH group (108 ± 1.7 μm³; p<0.05). CONCLUSION: Memantine prevented the nuclear size reduction of cardiomyocytes in rats exposed to cold stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increased incidence of cancer and a similarly increased number of surgeries for insertion of silicone breast implants, it is necessary to assess the effect of such material within the breast tissue, particularly in mammography, because of the reduction in the power of breast cancer diagnosis. In this work, we introduce a breast phantom with silicone implants in order to evaluate the influence of the implant on the visibility of the main mammographic findings: fibers, microcalcifications and tumor masses. In this proposed phantom, the breast tissue was simulated using gel paraffin. In the optical density of phantom mammograms with implants, a reduction in breast tissue visibility was seen corresponding to 23% when compared to a phantom without silicone implants. This poor visibility was due to the X-ray beam scattering on silicone material; this effect produced a loss of visibility in the areas adjacent to the implant. It is expected that the proposed phantom model may be used as a device for the establishment of a technical standard for these types of procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method to compute three-dimension (3D) left ventricle (LV) motion and its color coded visualization scheme for the qualitative analysis in SPECT images is proposed. It is used to investigate some aspects of Cardiac Resynchronization Therapy (CRT). The method was applied to 3D gated-SPECT images sets from normal subjects and patients with severe Idiopathic Heart Failure, before and after CRT. Color coded visualization maps representing the LV regional motion showed significant difference between patients and normal subjects. Moreover, they indicated a difference between the two groups. Numerical results of regional mean values representing the intensity and direction of movement in radial direction are presented. A difference of one order of magnitude in the intensity of the movement on patients in relation to the normal subjects was observed. Quantitative and qualitative parameters gave good indications of potential application of the technique to diagnosis and follow up of patients submitted to CRT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Most groups have reported disappointing results with autoaugmentation or detrusor myectomy for low capacity/compliance neuropathic bladders. Failure may be due to an ischemic diverticulum or mucosal shrinkage. We investigated whether a Silimed (R) silicone balloon placed in the bladder after autoaugmentation could prevent these problems, improving surgical results. Materials and Methods: We compared the results of standard bladder autoaugmentation in 12 children (group 1) with those in 10 (group 2) who underwent the same surgery using a bladder conformer. The conformer was a silicone balloon filled with saline that remained in the bladder for 2 weeks. All patients had a neuropathic bladder with poor capacity and compliance, resulting in urinary leakage between catheterizations. Preoperative and postoperative evaluation included a voiding diary, ultrasound, voiding cystourethrogram and urodynamics. Results: In group 1 only 1 patient became dry, 4 had little improvement in continence, 4 remained unchanged and 3 became worse. In group 2, 6 patients (60%) become continent without medication, 2 (20%) become continent with oxybutynin and 2 remained unchanged. Bladder capacity and compliance did not change significantly in group 1. However, in group 2 capacity changed from a mean of 140 to 240 ml and mean +/- SD compliance increased from 15.6 +/- 16.8 to 34.3 +/- 22.8 ml/cm H(2)O (p = 0.02). Conclusions: The inflatable balloon improved our long-term results of bladder auto-augmentation. A larger series may be necessary to confirm procedure efficacy and safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is a report of the characterization of superparamagnetic iron oxide nanoparticles coated with silicone used as a contrast agent in magnetic resonance imaging of the gastrointestinal tract. The hydrodynamic size of the contrast agent is 281.2 rim, where it was determined by transmission electron microscopy and a Fe(3)O(4) crystalline structure was identified by X-ray diffraction, also confirmed by Mossbauer Spectroscopy. The blocking temperature of 190 K was determined from magnetic measurements based on the Zero Field Cooled and Field Cooled methods. The hysteresis loops were measured at different temperatures below and above the blocking temperature. Ferromagnetic resonance analysis indicated the superparamagnetic nature of the nanoparticles and a strong temperature dependence of the peak-to-peak linewidth Delta H(pp), giromagnetic factor g, number of spins N(S) and relaxation time T(2) were observed. This behavior can be attributed to an increase in the superexchange interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. This study aimed to evaluate manometric parameters that may explain improvement in anal incontinence using a silicone bulking agent. Methods. Incontinent patients having internal sphincter defects were prospectively selected and injected with a silicone bulking agent. Manometry and endoanal ultrasound were performed before and 3 months after injections. Twenty continent healthy volunteers were used only for manometric comparison. Results. Thirty-five patients (28 females; mean age 60.3 years) and 20 controls entered this study. Patients had lower resting and squeeze pressures compared with controls (P<.05). Length of the high-pressure zone increased from 1 to 1.7 cm postinjection (P=.002). Asymmetry index showed a significant change postinjection (P<.001). Conclusion. Despite considerable clinical improvement, no significant increase in manometric pressures was noted posttreatment. There was significant improvement in both high-pressure zone and asymmetry index, and these findings may explain the mechanism of action of the bulking agent injected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The extent to which psychotic disorders fall into distinct diagnostic categories or can be regarded as lying on a single continuum is controversial. We compared lateral ventricle volumes between a large sample of patients with first-episode schizophrenia or bipolar disorder and a healthy control group from the same neighbourhood. Methods. Population-based MRI study with 88 first-episode psychosis (FEP) patients, grouped into those with schizophrenia/schizophreniform disorder (N = 62), bipolar disorder (N = 26) and 94 controls. Results. Right and left lateral ventricular and right temporal horn volumes were larger in FEP subjects than controls. Within the FEP sample, post-hoc tests revealed larger left lateral ventricles and larger right and left temporal horns in schizophrenia subjects relative to controls, while there was no difference between patients with bipolar disorder and controls. None of the findings was attributable to effects of antipsychotics. Conclusions. This large-sample population-based MRI study showed that neuroanatomical abnormalities in subjects with schizophrenia relative to controls from the same neighbourhood are evident at the first episode of illness, but are not detectable in bipolar disorder patients. These data are consistent with a model of psychosis in which early brain insults of neurodevelopmental origin are more relevant to schizophrenia than to bipolar disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate potential retinal neuroprotective effects of oral lamotrigine in rabbits after pars plana vitrectomy (PPV) and intravitreal silicone oil injection (SOI). Methods: Twelve New Zealand rabbits (weight, 2.0-2.5 kg) underwent PPV with SOI on the right eye. For 30 days postoperatively, 6 rabbits received a daily oral dose of lamotrigine (25 mg/kg), and 6 rabbits received a daily oral dose of water. The animals were killed 30 days after surgery. All retinas were processed histologically, immunostained using glial fibrillary acidic protein (GFAP), and analyzed by fluorescence microscopy. Retina sections from all groups were analyzed by TUNEL for the presence of apoptosis and stained with hematoxylin-eosin for morphologic analysis and retina cell density measurements in each layer using a Zeiss Axiophot microscope and KS 400 software. Results: Retinas from water-operated eyes showed a significant decrease in cell density associated with cell death compared with retinas from water-control eyes; cell density was reduced by 56% in the outer nuclear layer (ONL), 49% in the inner nuclear layer (INL), and 64% in the ganglion cell layer (GCL). Lamotrigine-operated retinas showed a reduction in cell death when compared with water-operated retinas; cell death was reduced by 52% in the ONL, 25% in the INL, and 56% in the GCL. Water-operated retinas showed TUNEL-positive cells and GFAP immunofluorescence throughout Muller cell processes; lamotrigine-operated retinas showed no TUNEL-positive cells and decreased GFAP staining when compared with water-operated retinas. Conclusions: PPV with SOI was associated with apoptosis of retinal cells and activation of glial cells in rabbit eyes. Oral lamotrigine administration provided protection against these effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The silicone implant has been widely used in facial aesthetic surgery for chin augmentation. A case of a 71-year-old woman with a lesion in the anterior mandibular region detected by radiographies and suggestive of benign soft tissue tumor is presented. The patient denied previous surgical intervention in the mental area. A biopsy was performed and initially interpreted as low-grade liposarcoma. After an immunohistochemistry study showing CD-68-positive cells and complementary information regarding a silicone implant for chin augmentation, the definitive diagnosis was silicone granuloma. This case reinforces that silicone implant in the mandibular region can be misdiagnosed as malignant tumor and the correct diagnosis is heavily dependent on close collaboration between clinician and pathologist in order to avoid unnecessary surgical intervention. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e21-e23)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic inflammation after augmentation mammaplasty with modern silicone implants is not currently recognized. In a prospective controlled study, C-reactive protein and other variables were monitored, aiming to test this hypothesis in a young cohort of patients. Females (18-30 years old, BMI = 18.5-30 kg/m(2), N = 52) were consecutively recruited for breast implant (n = 24, Group I) and for abdominal liposuction (n = 28, Group II/Controls). Patients were interviewed at baseline and followed until 6 months after operation. Variables included demographic and clinical information, surgical outcome, inflammatory markers and autoantibodies. Operations were well tolerated, without surgical or infectious complications. Mean prosthesis size was 258 +/- A 21 ml (range = 220-280) and mean aspirate of liposuction was 1972 +/- A 499 ml (range = 1200-3000). Preoperative, 2-month, and 6-month C-reactive protein concentrations for breast implant patients were 1.3 +/- A 1.2, 4.8 +/- A 3.0, and 4.3 +/- A 6.4 mg/l and for liposuction 3.5 +/- A 2.7, 3.5 +/- A 2.1, and 2.2 +/- A 2.2 mg/l, respectively. Change at 2 months was significant (p = 0.001). Autoantibody investigation failed to reveal remarkable aberrations, except for anticardiolipin elevation, which was nearly symmetrical in the two groups. C-reactive protein levels increased after operation and correlated with proinflammatory and procoagulatory indices. A mild increase in anticardiolipin IgM occurred but differences between populations were lacking. Despite excellent cosmetic outcomes and lack of complications, acute phase reaction could signal ongoing immunogenicity of silicone and long-term monitoring is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite electrodes were prepared using graphite powder and silicone rubber in different compositions. The use of such hydrophopic materials interned to diminish the swallowing observed in other cases when the electrodes are used in aqueous solutions for a long time. The composite was characterized for the response reproducibility, ohmic resistance, thermal behavior and active area. The voltammetric response in relation to analytes with known voltammetric behavior was also evaluated, always in comparison with the glassy carbon. The 70% (graphite, w/w) composite electrode was used in the quantitative determination of hydroquinone (HQ) in a DPV procedure in which a detection limit of 5.1 x 10(-8) mol L-1 was observed. HQ was determined in a photographic developer sample with errors lower then 1% in relation to the label value. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A graphite silicone-rubber composite electrode (GSR) was used for the determination of propranolol in drug formulation. Cyclic voltammetry (CV) at the GSR presented an irreversible oxidation peak at + 0.8V vs. SCE, in Britton Robinson (B-R) buffer pH 7.4. The quantitative determination was carried out using differential pulse voltammetry (DPV). Under optimized parameters a linear dynamic range from 5.0 to 80.6 mu mol L(-1) with a detection limit of 1.1 mu mol L(-1) was observed. A repeatability of 4.5 +/- 0.1 mu A (n = 10) peak current was found after 10 successive DPV voltammograms of propranolol in the same solution after surface renovations. Using the proposed electrode, propranolol was quantified in a pharmaceutical formulation with results that agreed within 95% confidence level (t-test) with those from an official method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new composite electrode based on multiwall carbon nanotubes (MWCNT) and silicone-rubber (SR) was developed and applied to the determination of propranolol in pharmaceutical formulations. The effect of using MWCNT/graphite mixtures in different proportions was also investigated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for electrochemical characterization of different electrode compositions. Propranolol was determined using MWCNT/SR 70% (m/m) electrodes with linear dynamic ranges up to 7.0 mu molL(-1) by differential pulse and up to 5.4 mu molL(-1) by square wave voltammetry, with LODs of 0.12 and 0.078 mu molL(-1), respectively. Analysis of commercial samples agreed with that obtained by the official spectrophotometric method. The electrode is mechanically robust and presented reproducible results and a long useful life.