9 resultados para Self-determined learning strategies
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
PIBIC-CNPq-Conselho Nacional de Desenvolvimento Cientifico e Technologico
Resumo:
The purpose of this investigation was to evaluate three learning methods for teaching basic oral surgical skills Thirty predoctoral dental students without any surgical knowledge or previous surgical experience were divided Into three groups (n=10 each) according to instructional strategy Group 1, active learning Group 2, text reading only, and Group 3, text reading and video demonstration After instruction, the apprentices were allowed to practice incision dissection and suture maneuvers in a bench learning model During the students' performance, a structured practice evaluation test to account for correct or incorrect maneuvers was applied by trained observers Evaluation tests were repeated after thirty and sixty days Data from resulting scores between groups and periods were considered for statistical analysis (ANOVA and Tukey Kramer) with a significant level of a=0 05 Results showed that the active learning group presented the significantly best learning outcomes related to immediate assimilation of surgical procedures compared to other groups All groups results were similar after sixty days of the first practice Assessment tests were fundamental to evaluate teaching strategies and allowed theoretical and proficiency learning feedbacks Repetition and interactive practice promoted retention of knowledge on basic oral surgical skills
Resumo:
Recent studies on the ecology of marine larvae suggest that retention near coastal areas and self-recruitment are probably much more common than previously thought. In light of this, the advective potential of pelagic stages can be partially determined by the timing of propagule release. We sampled the upper-shore levels of a subtropical coastline in southeastern Brazil to examine the temporal patterns of propagule release for the common barnacle Chthamalus bisinuatus and the periwinkle Nodilittorina lineolata. The release timing in both species was very consistent between sites a few kilometers apart. Barnacles released nauplii in a rhythmic pattern, mostly coinciding with neap tides, when the speed of tidal currents was lowest. There was no variation in propagule release in relation to diel or flood-ebb tidal cycles. Periwinkles released propagules in a very irregular pattern, which remarkably matched a time series of wave heights. Egg capsules were released during periods of rough seas, when onshore surface currents were expected to prevail. Eggs were released mostly during ebb tides, and there was no diel variation. Propagule release rhythms are usually viewed as a means to ensure fast offshore advection, thus avoiding presumed hazardous conditions for larvae. However, propagule release strategies in these upper-shore species would more likely contribute to the retention of offspring close to parental stocks.
Resumo:
Self controlling practice implies a process of decision making which suggests that the options in a self controlled practice condition could affect learners The number of task components with no fixed position in a movement sequence may affect the (Nay learners self control their practice A 200 cm coincident timing track with 90 light emitting diodes (LEDs)-the first and the last LEDs being the warning and the target lights respectively was set so that the apparent speed of the light along the track was 1 33 m/sec Participants were required to touch six sensors sequentially the last one coincidently with the lighting of the tar get light (timing task) Group 1 (n=55) had only one constraint and were instructed to touch the sensors in any order except for the last sensor which had to be the one positioned close to the target light Group 2 (n=53) had three constraints the first two and the last sensor to be touched Both groups practiced the task until timing error was less than 30 msec on three consecutive trials There were no statistically significant differences between groups in the number of trials needed to reach the performance criterion but (a) participants in Group 2 created fewer sequences corn pared to Group 1 and (b) were more likely to use the same sequence throughout the learning process The number of options for a movement sequence affected the way learners self-controlled their practice but had no effect on the amount of practice to reach criterion performance.
Resumo:
Psychosocial manifestations of erectile dysfunction (ED) differ across cultures. Understanding the treatment response to ED medications within cultural groups can aid in resource allocation and in developing treatment strategies. Evaluate the effect of sildenafil treatment on self-esteem, confidence, and sexual relationship satisfaction in Brazilian men with ED. The Self-Esteem and Relationship (SEAR) questionnaire, a validated, 14-question instrument developed to specifically address self-esteem and relationship issues within the context of ED. Men aged 18 years or older with a clinical diagnosis of ED (<= 21 on the Sexual Health Inventory for Men) and in a stable relationship with a partner during the study were eligible. The primary end point was a change from baseline in the self-esteem subscale of the SEAR questionnaire. Thirteen Brazilian sites participated in a randomized, double-blind, placebo-controlled trial of sildenafil treatment for ED. Patients were randomized to receive either 50 mg of sildenafil (adjustable to 25 mg or 100 mg based on patient response) or matching placebo approximately 1 hour before anticipated sexual activity but not more than once a day. At the end of double-blind treatment, 63 and 66 patients in the placebo and sildenafil groups, respectively, from 13 Brazilian sites were assessed for efficacy. Brazilian patients receiving sildenafil had significantly greater improvements in their scores on the SEAR self-esteem subscale (42.9 [95% confidence interval 35.7-50.0]) compared with placebo (21.1 [95% confidence interval 13.7-28.6]; P < 0.0001). Effect sizes ranged from 0.91 to 1.25 for individual SEAR components. The psychosocial parameters in Brazilian men with ED assessed by the SEAR questionnaire showed significant improvements in self-esteem, confidence, and relationships after treatment with sildenafil. Glina S, Damiao R, Abdo C, Afif-Abdo J, Tseng L-J, and Stecher V. Self-esteem, confidence, and relationships in Brazilian men with erectile dysfunction receiving sildenafil citrate: A randomized, parallel-group, double-blind, placebo-controlled study in Brazil. J Sex Med 2009;6:268-275.
Resumo:
Background: Many factors have been associated with the onset and maintenance of depressive symptoms in later life, although this knowledge is yet to be translated into significant health gains for the population. This study gathered information about common modifiable and non-modifiable risk factors for depression with the aim of developing a practical probabilistic model of depression that can be used to guide risk reduction strategies. \Methods: A cross-sectional study was undertaken of 20,677 community-dwelling Australians aged 60 years or over in contact with their general practitioner during the preceding 12 months. Prevalent depression (minor or major) according to the Patient Health Questionnaire (PHQ-9) assessment was the main outcome of interest. Other measured exposures included self-reported age, gender, education, loss of mother or father before age 15 years, physical or sexual abuse before age 15 years, marital status, financial stress, social support, smoking and alcohol use, physical activity, obesity, diabetes, hypertension, and prevalent cardiovascular diseases, chronic respiratory diseases and cancer. Results: The mean age of participants was 71.7 +/- 7.6 years and 57.9% were women. Depression was present in 1665 (8.0%) of our subjects. Multivariate logistic regression showed depression was independently associated with age older than 75 years, childhood adverse experiences, adverse lifestyle practices (smoking, risk alcohol use, physical inactivity), intermediate health hazards (obesity, diabetes and hypertension), comorbid medical conditions (clinical history of coronary heart disease, stroke, asthma, chronic obstructive pulmonary disease, emphysema or cancers), and social or financial strain. We stratified the exposures to build a matrix that showed that the probability of depression increased progressively with the accumulation of risk factors, from less than 3% for those with no adverse factors to more than 80% for people reporting the maximum number of risk factors. Conclusions: Our probabilistic matrix can be used to estimate depression risk and to guide the introduction of risk reduction strategies. Future studies should now aim to clarify whether interventions designed to mitigate the impact of risk factors can change the prevalence and incidence of depression in later life.
Resumo:
To evaluate the effects of different mechanical ventilation (MV) strategies on the mucociliary system. Experimental study. Twenty-seven male New Zealand rabbits. After anesthesia, animals were tracheotomized and ventilated with standard ventilation [tidal volume (Vt) 8 ml/kg, positive end expiratory pressure (PEEP) 5 cmH(2)O, flow 3 L/min, FiO(2) 0.4] for 30 min. Next, animals were randomized into three groups and ventilated for 3 h with low volume (LV): Vt 8 ml/kg, PEEP 5 cmH(2)O, flow 3 L/min (n = 6); high volume (HV): Vt 16 ml/kg, PEEP 5 cmH(2)O, flow 5 L/min (n = 7); or high pressure (HP): Ppeak 30 cmH(2)O, PEEP 12 cmH(2)O (n = 8). Six animals (controls) were ventilated for 10 min with standard ventilation. Vital signals, blood lactate, and respiratory system mechanics were verified. Tracheal tissue was collected before and after MV. Lung and tracheal tissue sections were stained to analyze inflammation and mucosubstances by the point-counting method. Electron microscopy verified tracheal cell ultrastructure. In situ tracheal ciliary beating frequency (CBF), determined using a videoscopic technique, and tracheal mucociliary transport (TMCT), assessed by stereoscopic microscope, were evaluated before and after MV. Respiratory compliance decreased in the HP group. The HV and HP groups showed higher lactate levels after MV. Macroscopy showed areas of atelectasis and congestion on HV and HP lungs. Lung inflammatory infiltrate increased in all ventilated groups. Compared to the control, ventilated animals also showed a reduction of total and acid mucus on tracheal epithelium. Under electron microscopy, injury was observed in the ciliated cells of the HP group. CBF decreased significantly after MV only in the HP group. TMCT did not change significantly in the ventilated groups. Different MV strategies induce not only distal lung alterations but also morphological and physiological tracheal alterations leading to mucociliary system dysfunction.
Resumo:
Objective: Our objective was to evaluate the association of chronic kidney dysfunction in patients with multi-vessel chronic coronary artery disease, preserved left ventricular function, and the possible interaction between received treatment and cardiovascular events. Methods: The glomerular filtration rate was determined at baseline on 611 patients who were randomized into three treatment groups: medical treatment, percutaneous coronary intervention, and coronary artery bypass surgery. Incidence of myocardial infarction, angina requiring a new revascularization procedure, and death were analyzed during 5 years in each group. Results: Of 611 patients, 112 (18%) were classified as having normal renal function, 349 (57%) were classified as having mild dysfunction, and 150 (25%) were classified as having moderate dysfunction. There were significant differences among the cumulative overall mortality curves among the three renal function groups. Death was observed more frequently in the moderate dysfunction group than the other two groups (P < .001). Interestingly, in patients with mild chronic kidney dysfunction, we observed that coronary artery bypass treatment presented a statistically higher percentage of event-free survival and lower percentage of mortality than did percutaneous coronary intervention or medical treatment Conclusions: Our results confirm that coronary artery disease accompanied by chronic kidney dysfunction has a worse prognosis, regardless of the therapeutic strategy for coronary artery disease, when renal function is at least mildly impaired. Additionally, our data suggest that the different treatment strategies available for stable coronary artery disease may have differential beneficial effects according to the range of glomerular filtration rate strata.
Resumo:
Purpose: To evaluate in vitro the microshear bond strength of adhesive systems applied to dentin according to manufacturers` instructions, associated or not with a hydrophobic layer of unfilled resin. Materials and Methods: Six self-etching adhesives (Clearfil SE Bond, Kuraray Medical; AdheSE, lvoclar Vivadent; Xeno III, Dentsply; I Bond, Heraeus-Kulzer; Bond Force, Tokuyama; Futurabond DC, Voco) were tested. The labial dentin of sixty bovine incisors was exposed, and the teeth were divided into two groups according to the application or not of an extra hydrophobic resin layer (Scotchbond Multi Purpose Plus, bottle 3). Six composite cylinders (Filtek Z250, 3M ESPE) were built up on each treated surface. Specimens were stored in distilled water at 37 C for 24 h and then subjected to the microshear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. Microshear bond strength values were analyzed by 2-way ANOVA and Tukey`s post-hoc test. Failure mode was determined using a stereomicroscope under 20X magnification. Results: The application of the hydrophobic resin layer did not affect bond strength, except for AdheSE. However, the bond strengths with the hydrophobic layer were similar among the six tested systems (Clearfil: 17.1 +/- 7.9; AdheSE: 14.5 +/- 7.1; Xeno III: 12.8 +/- 7.7; I Bond: 9.5 +/- 5.8; Bond Force: 17.5 +/- 4.1; Futurabond: 7.7 +/- 2.3). When used as recommended by the manufacturers, Bond Force presented statistically higher bond strength than AdheSE and I Bond (p < 0.05) (Clearfil 10.4 +/- 4.9; AdheSE 1.6 +/- 1.6; Xeno III: 9.0 +/- 3.8; I Bond: 3.0 +/- 1.5; Bond Force: 14 +/- 3.9; Futurabond: 8.8 +/- 3.8). Failure mode was predominantly adhesive. Conclusion: The bond strength of the self-etching systems tested was not significantly affected by the application of a hydrophobic layer, but a significant improvement was observed in AdheSE.