59 resultados para Safe Minimum Standard
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
BACKGROUND: Original sevoflurane (Sevo A) is made with water, while a generic sevoflurane (Sevocris) is produced with propylene glycol as a stabilizing additive. We investigated whether the original and generic sevoflurane preparations differed in terms of their minimum alveolar concentration (MAC) values and hemodynamic effects. METHODS: Sixteen pigs weighing 31.6±1.8 kg were randomly assigned to the Sevo A or Sevocris groups. After anesthesia induction via mask with the appropriate sevoflurane preparation (6% in 100% oxygen), the MAC was determined for each animal. Hemodynamic and oxygenation parameters were measured at 0.5 MAC, 1 MAC and 1.5 MAC. Histopathological analyses of lung parenchyma were performed. RESULTS: The MAC in the Sevo A group was 4.4±0.5%, and the MAC in the Sevocris group was 4.1±0.7%. Hemodynamic and metabolic parameters presented significant differences in a dose-dependent pattern as expected, but they did not differ between groups. Cardiac indices and arterial pressures decreased in both groups when the sevoflurane concentration increased from 0.5 to 1 and 1.5 MAC. The oxygen delivery index (DO2I) decreased significantly at 1.5 MAC. CONCLUSION: Propylene glycol as an additive for sevoflurane seems to be as safe as a water additive, at least in terms of hemodynamic and pulmonary effects.
Resumo:
An analysis of the experimental conditions under which low-frequency (70-150 kHz) Alfven eigertmodes (AE) are excited during the monster sawtooth in Joint European Torus [F Romanelli et al, Proceedings of the 22nd IAEA Fusion Energy Conference, Geneva, Switzerland, 2008] is presented for the specific case of a discharge with ion cyclotron heating (5 MW) Using a simplified AE model for modes excited at the Alfven wave continuum maximum with geodesic corrections taken into account, the temporal evolution of the value of the safety factor q(0) at the magnetic axis is determined We describe a new scheme to determine the time variation of q(0) that works under conditions in which other standard diagnostics, such as the motional Stark effect do not give reliable results such as during a monster sawtooth [doi 10 1063/1 3494212]
Resumo:
Bleeding is not uncommon following endoscopic sphincterotomy. Supra-papillary puncture (SPP) might be safer than standard cannulation (SC) techniques in patients with coagulopathy. The aim of the study was to compare the safety and effectiveness of SPP and SC. This was a prospective case control intervention study. Decompensated cirrhotic patients with coagulopathy and choledocolithiasis underwent SC and SPP methods for biliary access. One hundred five patients (56 [53.3%] men, mean [SD] age 56 [15.8]) underwent ERCP. SC and SPP were performed in 63 and 42 patients, respectively. Biliary access was achieved in 56/63 (89%) and 40/42 (95%) of patients undergoing SC and SPP, respectively (P = 0.13; 95% CI [-0.16; 0.03]). Complications occurred in 10/63 (15.8%) patients undergoing SC and 5/42 (11.9%) SPP (P = 0.28; 95% CI [-0.17, 0.16]). Five (7.9%) and two (3.2%) episodes of post-sphincterotomy bleeding was seen in the SC and SPP groups, respectively (P = 0.36; 95% CI [-0.16, 0.05]). In contrast, three (4.8%) episodes of pancreatitis were seen in the SC and none in the SPP group (P = 0.05; 95% CI [0.001; 0.004]). A cost-effectiveness analysis demonstrated that SPP is an acceptable alternative at an ICER of US$ 5,974.92 per additional successful procedure. SPP is a safe and effective technique for the management of common bile duct stones in decompensated cirrhotic patients. Conditional to the willingness-to-pay and to the local ERCP-related costs, SPP is also a cost-effective alternative to the SC methods. SPP is associated with a lower rate of complications but larger studies to validate these findings are necessary.
Resumo:
Apesar dos elevados riscos à saúde e capacidade para o trabalho dos eletricitários, há carência de estudos sobre o tema no Brasil. O objetivo desse estudo é identificar o perfil de saúde e capacidade para o trabalho de eletricitários de São Paulo. Foi feito um estudo transversal junto a 475 trabalhadores de uma empresa do setor eletricitário. A coleta de dados foi por meio de questionários sobre capacidade para o trabalho, estado de saúde, estresse no trabalho, atividade física, dependência ao tabaco e ao álcool. A consistência interna das escalas foi avaliada usando o coeficiente alfa de Cronbach. Foi feita análise descritiva por meio das médias, desvios-padrão, valores mínimos e máximos dos escores e proporções para as variáveis qualitativas. O estado de saúde dos trabalhadores apresentou pontuação elevada nas dimensões analisadas, com médias entre 72,8 a 91,2 (escore de 0,0 a 100,0 pontos). A capacidade para o trabalho teve pontuação elevada, com média de 41,8 (escore de 7,0 a 49,0 pontos). Concluiu-se que os trabalhadores da população de estudo apresentaram elevados padrões do estado de saúde e da capacidade para o trabalho. Sugere-se o desenvolvimento de estudos longitudinais para avaliar relações causais e a existência de efeito do trabalhador sadio.
Resumo:
O trabalho tem como objetivo descrever e avaliar as Cozinhas Comunitárias (CC) apoiadas pelo Ministério do Desenvolvimento Social (MDS) em funcionamento no Brasil em 2006. Trata-se de estudo transversal que investigou as CC, com projetos contemplados nos editais do MDS realizados entre os anos de 2003 a 2005. Inicialmente foram identificadas as CC em funcionamento e estas CC foram visitadas para a coleta de dados relativos ao atendimento prestado, avaliação da estrutura física e das refeições oferecidas. A estrutura física foi avaliada por meio de um check-list, baseado nas exigências da legislação sanitária, e a oferta de refeições foi caracterizada pelos alimentos e preparações oferecidas pelas CC para determinar o valor nutricional das refeições. A maioria das cozinhas financiadas (60%) estava em fase de implementação no momento da entrevista, entre as cozinhas em funcionamento, a maioria estava localizada nos Estados de Santa Catarina e Paraná. Observou-se também que cerca de 20% das cozinhas não ofereciam refeições regularmente. Ao realizar a avaliação nutricional das refeições, foi observada uma grande heterogeneidade na oferta de alimentos. Ao avaliar as condições higiênico-sanitárias, quase a totalidade das CC foram classificadas como deficientes ou regulares, indicando inadequação na produção de refeições. O Programa das Cozinhas Comunitárias pode exercer importante papel nas políticas de segurança alimentar e nutricional do país, no entanto, devem ser realizados esforços no sentido de garantir a implantação em comunidades situadas nos Estados menos desenvolvidos, com fixação de números mínimos para atendimento, de parâmetros nutricionais e garantia de fornecimento seguro de alimentos
Resumo:
Background: Obstructive Sleep Apnea (OSA) is tightly linked to some components of Metabolic Syndrome (MetS). However, most of the evidence evaluated individual components of the MetS or patients with a diagnosis of OSA that were referred for sleep studies due to sleep complaints. Therefore, it is not clear whether OSA exacerbates the metabolic abnormalities in a representative sample of patients with MetS. Methodology/Principal Findings: We studied 152 consecutive patients (age 48 +/- 9 years, body mass index 32.3 +/- 3.4 Kg/m(2)) newly diagnosed with MetS (Adult Treatment Panel III). All participants underwent standard polysomnography irrespective of sleep complaints, and laboratory measurements (glucose, lipid profile, uric acid and C-reactive protein). The prevalence of OSA (apnea-hypopnea index >= 15 events per hour of sleep) was 60.5%. Patients with OSA exhibited significantly higher levels of blood pressure, glucose, triglycerides, cholesterol, LDL, cholesterol/HDL ratio, triglycerides/HDL ratio, uric acid and C-reactive protein than patients without OSA. OSA was independently associated with 2 MetS criteria: triglycerides: OR: 3.26 (1.47-7.21) and glucose: OR: 2.31 (1.12-4.80). OSA was also independently associated with increased cholesterol/HDL ratio: OR: 2.38 (1.08-5.24), uric acid: OR: 4.19 (1.70-10.35) and C-reactive protein: OR: 6.10 (2.64-14.11). Indices of sleep apnea severity, apnea-hypopnea index and minimum oxygen saturation, were independently associated with increased levels of triglycerides, glucose as well as cholesterol/HDL ratio, uric acid and C-reactive protein. Excessive daytime sleepiness had no effect on the metabolic and inflammatory parameters. Conclusions/Significance: Unrecognized OSA is common in consecutive patients with MetS. OSA may contribute to metabolic dysregulation and systemic inflammation in patients with MetS, regardless of symptoms of daytime sleepiness.
Resumo:
A compact frequency standard based on an expanding cold (133)CS cloud is under development in our laboratory. In a first experiment, Cs cold atoms were prepared by a magneto-optical trap in a vapor cell, and a microwave antenna was used to transmit the radiation for the clock transition. The signal obtained from fluorescence of the expanding cold atoms cloud is used to lock a microwave chain. In this way the overall system stability is evaluated. A theoretical model based on a two-level system interacting with the two microwave pulses enables interpretation for the observed features, especially the poor Ramsey fringes contrast. (C) 2008 Optical Society of America.
Resumo:
Background: Recent advances in laparoscopic devices and experience with advanced techniques have increased the indications for laparoscopic liver. Aim: The aim of this work was to present a video with technical aspects of a pure laparoscopic left hemi-hepatectomy (segments 2, 3, and 4) by using the intrahepatic Glissonian approach and control of venous outflow without hilar dissection or the Pringle maneuver. Patient and Method: A 63-year-old woman with a 5-cm solitary liver metastasis was referred for treatment. Four trocars were used. The left lobe was pulled upward and the lesser omentum was divided, exposing Arantius' ligament. This ligament is a useful landmark for the identification of the main left Glissonian pedicle. A small anterior incision was made in front of the hilum, and a large clamp was introduced behind the Arantius' ligament toward the anterior incision, allowing control of the left main sheath. Ischemic discoloration of the left liver was achieved and marked with cautery. The vascular clamp was replaced by a stapler. If ischemic delineation was coincident with a previously marked area, the stapler was fired. The left hepatic vein was dissected and encircled. Parenchymal transection and vascular control of the hepatic veins were accomplished with a Harmonic scalpel and an endoscopic stapling device, as appropriate. All these steps were performed without the Pringle maneuver and without hand assistance. Results: Operative time was 220 minutes with minimum blood loss. Hospital stay was 4 days. Pathology showed free surgical margins. The patient is alive with no signs of recurrence 18 months after the operation. Conclusion: Totally laparoscopic left hemihepatectomy is safe and feasible in selected patients and should be considered for patients with benign or malignant liver neoplasms. The described technique, with the use of the intrahepatic Glissonian approach and control of venous outflow, may facilitate laparoscopic left hemihepatectomy by reducing the technical difficulties in pedicle control and may decrease bleeding during liver transection.
Resumo:
Context. Emission lines formed in decretion disks of Be stars often undergo long-term cyclic variations, especially in the violet-to-red (V/R) ratio of their primary components. The underlying structural and dynamical variations of the disks are only partly understood. From observations of the bright Be-shell star. Tau, the possibly broadest and longest data set illustrating the prototype of this behaviour was compiled from our own and archival observations. It comprises optical and infrared spectra, broad-band polarimetry, and interferometric observations. Aims. The dense, long-time monitoring permits a better separation of repetitive and ephemeral variations. The broad wavelength coverage includes lines formed under different physical conditions, i.e. different locations in the disk, so that the dynamics can be probed throughout much of the disk. Polarimetry and interferometry constrain the spatial structure. All together, the objective is a better understand the dynamics and life cycle of decretion disks. Methods. Standard methods of data acquisition, reduction, and analysis were applied. Results. From 3 V/R cycles between 1997 and 2008, a mean cycle length in Ha of 1400-1430 days was derived. After each minimum in V/R, the shell absorption weakens and splits into two components, leading to 3 emission peaks. This phase may make the strongest contribution to the variability in cycle length. There is no obvious connection between the V/R cycle and the 133-day orbital period of the not otherwise detected companion. V/R curves of different lines are shifted in phase. Lines formed on average closer to the central star are ahead of the others. The shell absorption lines fall into 2 categories differing in line width, ionization/excitation potential, and variability of the equivalent width. They seem to form in separate regions of the disk, probably crossing the line of sight at different times. The interferometry has resolved the continuum and the line emission in Br gamma and HeI 2.06. The phasing of the Br gamma emission shows that the photocenter of the line-emitting region lies within the plane of the disk but is offset from the continuum source. The plane of the disk is constant throughout the observed V/R cycles. The observations lay the foundation for the fully self-consistent, one-armed, disk-oscillation model developed in Paper II.
Resumo:
In this work we investigate the duality linking standard and tachyon scalar field homogeneous and isotropic cosmologies in N + 1 dimensions. We determine the transformation between standard and tachyon scalar fields and between their associated potentials, corresponding to the same background evolution. We show that, in general, the duality is broken at a perturbative level, when deviations from a homogeneous and isotropic background are taken into account. However, we find that for slow-rolling fields the duality is still preserved at a linear level. We illustrate our results with specific examples of cosmological relevance, where the correspondence between scalar and tachyon scalar field models can be calculated explicitly.
Resumo:
The optimal discrimination of nonorthogonal quantum states with minimum error probability is a fundamental task in quantum measurement theory as well as an important primitive in optical communication. In this work, we propose and experimentally realize a new and simple quantum measurement strategy capable of discriminating two coherent states with smaller error probabilities than can be obtained using the standard measurement devices: the Kennedy receiver and the homodyne receiver.
Resumo:
We study the massless scalar, Dirac, and electromagnetic fields propagating on a 4D-brane, which is embedded in higher-dimensional Gauss-Bonnet space-time. We calculate, in the time domain, the fundamental quasinormal modes of a spherically symmetric black hole for such fields. Using WKB approximation we study quasinormal modes in the large multipole limit. We observe also a universal behavior, independent on a field and value of the Gauss-Bonnet parameter, at an asymptotically late time.
Resumo:
An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Background: Although the Clock Drawing Test (CDT) is the second most used test in the world for the screening of dementia, there is still debate over its sensitivity specificity, application and interpretation in dementia diagnosis. This study has three main aims: to evaluate the sensitivity and specificity of the CDT in a sample composed of older adults with Alzheimer`s disease (AD) and normal controls; to compare CDT accuracy to the that of the Mini-mental State Examination (MMSE) and the Cambridge Cognitive Examination (CAMCOG), and to test whether the association of the MMSE with the CDT leads to higher or comparable accuracy as that reported for the CAMCOG. Methods: Cross-sectional assessment was carried out for 121 AD and 99 elderly controls with heterogeneous educational levels from a geriatric outpatient clinic who completed the Cambridge Examination for Mental Disorder of the Elderly (CAMDEX). The CDT was evaluated according to the Shulman, Mendez and Sunderland scales. Results: The CDT showed high sensitivity and specificity. There were significant correlations between the CDT and the MMSE (0.700-0.730; p < 0.001) and between the CDT and the CAMCOG (0.753-0.779; p < 0.001). The combination of the CDT with the MMSE improved sensitivity and specificity (SE = 89.2-90%; SP = 71.7-79.8%). Subgroup analysis indicated that for elderly people with lower education, sensitivity and specificity were both adequate and high. Conclusions: The CDT is a robust screening test when compared with the MMSE or the CAMCOG, independent of the scale used for its interpretation. The combination with the MMSE improves its performance significantly, becoming equivalent to the CAMCOG.