24 resultados para Robot collaborativi layout gripper macchine automatiche
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This paper develops a Markovian jump model to describe the fault occurrence in a manipulator robot of three joints. This model includes the changes of operation points and the probability that a fault occurs in an actuator. After a fault, the robot works as a manipulator with free joints. Based on the developed model, a comparative study among three Markovian controllers, H(2), H(infinity), and mixed H(2)/H(infinity) is presented, applied in an actual manipulator robot subject to one and two consecutive faults.
Resumo:
This work presents an automated system for the measurement of form errors of mechanical components using an industrial robot. A three-probe error separation technique was employed to allow decoupling between the measured form error and errors introduced by the robotic system. A mathematical model of the measuring system was developed to provide inspection results by means of the solution of a system of linear equations. A new self-calibration procedure, which employs redundant data from several runs, minimizes the influence of probes zero-adjustment on the final result. Experimental tests applied to the measurement of straightness errors of mechanical components were accomplished and demonstrated the effectiveness of the employed methodology. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
By means of continuous topology optimization, this paper discusses the influence of material gradation and layout in the overall stiffness behavior of functionally graded structures. The formulation is associated to symmetry and pattern repetition constraints, including material gradation effects at both global and local levels. For instance, constraints associated with pattern repetition are applied by considering material gradation either on the global structure or locally over the specific pattern. By means of pattern repetition, we recover previous results in the literature which were obtained using homogenization and optimization of cellular materials.
Resumo:
Simulated annealing (SA) is an optimization technique that can process cost functions with degrees of nonlinearities, discontinuities and stochasticity. It can process arbitrary boundary conditions and constraints imposed on these cost functions. The SA technique is applied to the problem of robot path planning. Three situations are considered here: the path is represented as a polyline; as a Bezier curve; and as a spline interpolated curve. In the proposed SA algorithm, the sensitivity of each continuous parameter is evaluated at each iteration increasing the number of accepted solutions. The sensitivity of each parameter is associated to its probability distribution in the definition of the next candidate. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Background: Positive surgical margin (PSM) after radical prostatectomy (RP) has been shown to be an independent predictive factor for cancer recurrence. Several investigations have correlated clinical and histopathologic findings with surgical margin status after open RP. However, few studies have addressed the predictive factors for PSM after robot-assisted laparoscopic RP (RARP). Objective: We sought to identify predictive factors for PSMs and their locations after RARP. Design, setting, and participants: We prospectively analyzed 876 consecutive patients who underwent RARP from January 2008 to May 2009. Intervention: All patients underwent RARP performed by a single surgeon with previous experience of > 1500 cases. Measurements: Stepwise logistic regression was used to identify potential predictive factors for PSM. Three logistic regression models were built: (1) one using preoperative variables only, (2) another using all variables (preoperative, intraoperative, and postoperative) combined, and (3) one created to identify potential predictive factors for PSM location. Preoperative variables entered into the models included age, body mass index (BMI), prostate-specific antigen, clinical stage, number of positive cores, percentage of positive cores, and American Urological Association symptom score. Intra-and postoperative variables analyzed were type of nerve sparing, presence of median lobe, percentage of tumor in the surgical specimen, gland size, histopathologic findings, pathologic stage, and pathologic Gleason grade. Results and limitations: In the multivariable analysis including preoperative variables, clinical stage was the only independent predictive factor for PSM, with a higher PSM rate for T3 versus T1c (odds ratio [OR]: 10.7; 95% confidence interval [CI], 2.6-43.8) and for T2 versus T1c (OR: 2.9; 95% CI, 1.9-4.6). Considering pre-, intra-, and postoperative variables combined, percentage of tumor, pathologic stage, and pathologic Gleason score were associated with increased risk of PSM in the univariable analysis (p < 0.001 for all variables). However, in the multivariable analysis, pathologic stage (pT2 vs pT1; OR: 2.9; 95% CI, 1.9-4.6) and percentage of tumor in the surgical specimen (OR: 8.7; 95% CI, 2.2-34.5; p = 0.0022) were the only independent predictive factors for PSM. Finally, BMI was shown to be an independent predictive factor(OR: 1.1; 95% CI, 1.0-1.3; p = 0.0119) for apical PSMs, with increasing BMI predicting higher incidence of apex location. Because most of our patients were referred from other centers, the biopsy technique and the number of cores were not standardized in our series. Conclusions: Clinical stage was the only preoperative variable independently associated with PSM after RARP. Pathologic stage and percentage of tumor in the surgical specimen were identified as independent predictive factors for PSMs when analyzing pre-, intra-, and postoperative variables combined. BMI was shown to be an independent predictive factor for apical PSMs. (C) 2010 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
Background: Several studies have shown that robot-assisted laparoscopic radical prostatectomy (RALP) is feasible, with favorable complication rates and short hospital times. However, the early recovery of urinary continence remains a challenge to be overcome. Objective: We describe our technique of periurethral retropubic suspension stitch during RALP and report its impact on early recovery of urinary continence. Design, setting, and participants: We analyze prospectively 331 consecutive patients who underwent RALP, 94 without the placement of suspension stitch (group 1) and 237 with the application of the suspension stitch (group 2). Surgical procedure: The only difference between the groups was the placement of the puboperiurethral stitch after the ligation of the dorsal venous complex (DVC). The periurethral retropubic stitch was placed using a 12-in monofilament polyglytone suture on a CTI needle. The stitch was passed from right to left between the urethra and DVC, and then through the periostium on the pubic bone. The stitch was passed again through the DVC, and then through the pubic bone in a figure eight, and then tied. Measurements: Continence rates were assessed with a self-administered validated questionnaire (Expanded Prostate Cancer Index Composite [EPIC] at 1, 3, 6, and 12 mo after the procedure. Continence was defined as the use of no absorbent pads or no leakage of urine. Results and limitations: In group 1, the continence rate at 1, 3, 6, and 12 mo postoperatively was 33%, 83%, 94.7%, and 95.7%, respectively; in group 2, the continence rate was 40%, 92.8%, 97.9%, and 97.9%, respectively. The suspension technique resulted in significantly greater continence rates at 3 mo after RALP (p = 0.013). The median/mean interval to recovery of continence was also statistically significantly shorter in the suspension group (median: 6 wk; mean: 7.338 wk: 95% confidence interval [CI]: 6.387-8.288) compared to the non-suspension group (median: 7 wk; mean: 9.585 wk: 95% CI: 7.558-11.612; log rank test, p = 0.02). Conclusions: The suspension stitch during RALP resulted in a statistically significantly shorter interval to recovery of continence and higher continence rates at 3 mo after the procedure. (C) 2009 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Background: Widespread use of prostate-specific antigen screening has resulted in younger and healthier men being diagnosed with prostate cancer. Their demands and expectations of surgical intervention are much higher and cannot be adequately addressed with the classic trifecta outcome measures. Objective: A new and more comprehensive method for reporting outcomes after radical prostatectomy, the pentafecta, is proposed. Design, setting, and participants: From January 2008 through September 2009, details of 1111 consecutive patients who underwent robot-assisted radical prostatectomy performed by a single surgeon were retrospectively analyzed. Of 626 potent men, 332 who underwent bilateral nerve sparing and who had 1 yr of follow-up were included in the study group. Measurements: In addition to the traditional trifecta outcomes, two perioperative variables were included in the pentafecta: no postoperative complications and negative surgical margins. Patients who attained the trifecta and concurrently the two additional outcomes were considered as having achieved the pentafecta. A logistic regression model was created to evaluate independent factors for achieving the pentafecta. Results and limitations: Continence, potency, biochemical recurrence-free survival, and trifecta rates at 12 mo were 96.4%, 89.8%, 96.4%, and 83.1%, respectively. With regard to the perioperative outcomes, 93.4% had no postoperative complication and 90.7% had negative surgical margins. The pentafecta rate at 12 mo was 70.8%. On multivariable analysis, patient age (p = 0.001) was confirmed as the only factor independently associated with the pentafecta. Conclusions: A more comprehensive approach for reporting prostate surgery outcomes, the pentafecta, is being proposed. We believe that pentafecta outcomes more accurately represent patients` expectations after minimally invasive surgery for prostate cancer. This approach may be beneficial and may be used when counseling patients with clinically localized disease. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
An alternative technique for the fabrication of disposable electrochemical microcells containing working, reference and auxiliary electrodes on a single device is reported. The procedure is based on thermal-transfer of toner masks onto CD-R (recordable compact discs) gold surfaces to define the layout of the electrodes (contour). In a subsequent step, the layout is manually painted with a permanent marker pen. The unprotected gold surface is conveniently etched (chemical corrosion) and the ink is then easily removed with ethanol, generating gold surfaces without contamination. The final and reproducible area of the electrodes is defined by heat transference of a second toner mask. Silver epoxy is deposited on one of the gold bands which is the satisfactorily used as reference electrode. These microcells were electrochemically characterized by cyclic, linear, and square wave voltammetry, and several electroactive species were used as model systems. The area reproducibility of the electrodes for different microcells was studied and a relative standard deviation better than 1,0% (n = 10) was obtained. Disposable electrochemical microcells were successfully used in analysis of liquid samples with volumes lower than 200 µL and good stability and reproducibility (RSD less than 2.0%) were achieved. These microcells were also evaluated for quantification of paracetamol and dipyrone in pharmaceutical formulations.
Resumo:
The Brazilian Synchrotron Light Laboratory [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP, Brazil] is the first commissioned synchrotron light source in the southern hemisphere. The first wiggler macromolecular crystallography beamline (MX2) at the LNLS has been recently constructed and brought into operation. Here the technical design, experimental set-up, parameters of the beamline and the first experimental results obtained at MX2 are described. The beamline operates on a 2.0 T hybrid 30-pole wiggler, and its optical layout includes collimating mirror, Si( 111) double-crystal monochromator and toroidal bendable mirror. The measured flux density at the sample position at 8.7 eV reaches 4.8 x 10(11) photons s(-1) mm(-2) (100 mA)(-1). The beamline is equipped with a MarResearch Desktop Beamline Goniostat (MarDTB) and 3 x 3 MarMosaic225 CCD detector, and is controlled by a customized version of the Blu-Ice software. A description of the first X-ray diffraction data sets collected at the MX2 LNLS beamline and used for macromolecular crystal structure solution is also provided.
Resumo:
A simple and easy approach to produce polymeric microchips with integrated copper electrodes for capacitively coupled contactless conductivity detection (CD) is described. Copper electrodes were fabricated using a printed circuit board (PCB) as an inexpensive thin-layer of metal. The electrode layout was first drawn and laser printed on a wax paper sheet. The toner layer deposited on the paper sheet was thermally transferred to the PCB surface working as a mask for wet chemical etching of the copper layer. After the etching step, the toner was removed with an acetonitrile-dampened cotton. A poly(ethylene terephthalate) (PET) film coated with a thin thermo-sensitive adhesive layer was used to laminate the PCB plate providing an insulator layer of the electrodes to perform CID measurements. Electrophoresis microchannels were fabricated in poly(dimethylsiloxane) (PDMS) by soft lithography and reversibly sealed against the PET film. These hybrid PDMS/PET chips exhibited a stable electroosmotic mobility of 4.25 +/- 0.04 x 10(-4) V cm(-2) s(-1), at pH 6.1, over fifty runs. Efficiencies ranging from 1127 to 1690 theoretical plates were obtained for inorganic cations.
Resumo:
This paper presents a small-area CMOS current-steering segmented digital-to-analog converter (DAC) design intended for RF transmitters in 2.45 GHz Bluetooth applications. The current-source design strategy is based on an iterative scheme whose variables are adjusted in a simple way, minimizing the area and the power consumption, and meeting the design specifications. A theoretical analysis of static-dynamic requirements and a new layout strategy to attain a small-area current-steering DAC are included. The DAC was designed and implemented in 0.35 mu m CMOS technology, requiring an active area of just 200 mu m x 200 mu m. Experimental results, with a full-scale output current of 700 mu A and a 3.3 V power supply, showed a spurious-free dynamic range of 58 dB for a 1 MHz output sine wave and sampling frequency of 50 MHz, with differential and integral nonlinearity of 0.3 and 0.37 LSB, respectively.
Resumo:
This work deals with neural network (NN)-based gait pattern adaptation algorithms for an active lower-limb orthosis. Stable trajectories with different walking speeds are generated during an optimization process considering the zero-moment point (ZMP) criterion and the inverse dynamic of the orthosis-patient model. Additionally, a set of NNs is used to decrease the time-consuming analytical computation of the model and ZMP. The first NN approximates the inverse dynamics including the ZMP computation, while the second NN works in the optimization procedure, giving an adapted desired trajectory according to orthosis-patient interaction. This trajectory adaptation is added directly to the trajectory generator, also reproduced by a set of NNs. With this strategy, it is possible to adapt the trajectory during the walking cycle in an on-line procedure, instead of changing the trajectory parameter after each step. The dynamic model of the actual exoskeleton, with interaction forces included, is used to generate simulation results. Also, an experimental test is performed with an active ankle-foot orthosis, where the dynamic variables of this joint are replaced in the simulator by actual values provided by the device. It is shown that the final adapted trajectory follows the patient intention of increasing the walking speed, so changing the gait pattern. (C) Koninklijke Brill NV, Leiden, 2011