210 resultados para Repeated Load Triaxial (RLT) test

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The wide production of construction and demolition waste and its illegal deposition are serious current problems in Brazil. This research proposes to evaluate the feasibility of using aggregate from recycled construction and demolition waste (RCDW) in pavement applications. A laboratory program was conducted by geotechnical characterization, bearing capacity and repeated load triaxial tests. The results show that the composition and the compactive effort influence on the physical characteristics of the RCDW aggregate. The compaction process has promoted a partial crushing and breakage of RCDW particles, changing the grain-size distribution and increasing the percentage of cubic grains. This physical change contributes to a better densification of the RCDW aggregate and consequently an improvement in bearing capacity, resilient modulus and resistance to permanent deformation. The results have shown that the RCDW aggregate may be utilized as coarse base and sub-base layer for low-volume roads. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study tested the concurrent and construct validity of a newly developed OMNI-Kayak Scale, testing 8 male kayakers who performed a flatwater load-incremented ""shuttle"" test over a 500-m course and 3 estimation-production trials over a 1,000-m course. Velocity, blood lactate concentration, heart rate, and rating of perceived exertion (RPE), using the OMNI-Kayak RPE Scale and the Borg 6-20 Scale were recorded. OMNI-Kayak Scale RPE was highly correlated with velocity, the Borg 6-20 Scale RPE, blood lactate, and heart rate for both load-incremented test (rs=.87-.96), and estimation trials (rs=.75-.90). There were no significant differences among velocities, heart rate and blood lactate concentration between estimation and production trials. The OMNI-Kayak RPE Scale showed concurrent and construct validity in assessing perception of effort in flatwater kayaking and is a valid tool for self-regulation of exercise intensity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The multivariate skew-t distribution (J Multivar Anal 79:93-113, 2001; J R Stat Soc, Ser B 65:367-389, 2003; Statistics 37:359-363, 2003) includes the Student t, skew-Cauchy and Cauchy distributions as special cases and the normal and skew-normal ones as limiting cases. In this paper, we explore the use of Markov Chain Monte Carlo (MCMC) methods to develop a Bayesian analysis of repeated measures, pretest/post-test data, under multivariate null intercept measurement error model (J Biopharm Stat 13(4):763-771, 2003) where the random errors and the unobserved value of the covariate (latent variable) follows a Student t and skew-t distribution, respectively. The results and methods are numerically illustrated with an example in the field of dentistry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study investigated the energy system contributions of judo athletes to the Special Judo Fitness Test (SJFT). Methods: Fourteen male judo athletes performed the SJFT, which comprised three periods of judo activity (A = 15 s, B and C = 30 s) interspersed with 10 s rest intervals. During this test, one athlete threw two others positioned 6 m from each other using the ippon-seoi-nage technique. The fractions of the aerobic, anaerobic alactic and anaerobic lactic systems were calculated based on oxygen uptake, the fast component of excess postexercise oxygen uptake, and changes in net blood lactate, respectively. The contribution of the three energy systems was compared using a repeated measures analysis of variance and Bonferroni's multiple comparisons test. Compound symmetry, or sphericity, was determined by Mauchly's test. A level of significance of 5% (P < .05) was adopted in all analyses. Results: The alactic energy system presented a higher (F = 20.9; P < .001; power observed = 1.0) contribution (86.8 +/- 23.6 kJ; 42.3 +/- 5.9%) during the test when compared with both aerobic (57.1 +/- 11.3 kJ; 28.2 +/- 2.9%) and lactic (58.9 +/- 12.1 kJ; 29.5 +/- 6.2%) energy systems (P < .001 for both comparisons). Conclusions: The higher alactic contribution seems to be a consequence of the high-intensity efforts performed during the test, and its intermittent nature. Thus, when using the SJFT, coaches are evaluating mainly their athletes' anaerobic alactic system, which can be considered to be the most predominant system contributing to the actions (techniques) performed in the match.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human bocavirus (HBoV) is a parvovirus recently identified in association with acute respiratory infections (ARI). Despite its worldwide occurrence, little is known on the pathogenesis of HBoV infections. In addition, few systematic studies of HBoV in ARI have been conducted in Latin America. Therefore, in order to test whether active viral replication of human bocavirus is associated with respiratory diseases and to understand the clinical impact of this virus in patients with these diseases, we performed a 3-year retrospective hospital-based study of HBoV in outpatients and inpatients with symptoms of Acute Respiratory Infections (ARI) in Brazil. Nasopharyngeal aspirates (NPAs) from 1015 patients with respiratory symptoms were tested for HBoV DNA by PCR. All samples positive for HBoV were tested by PCR for all other respiratory viruses, had HBoV viral loads determined by quantitative real time PCR and, when possible, were tested by RT-PCR for HBoV VP1 mRNA, as evidence of active viral replication. HBoV was detected in 4.8% of patients, with annual rates of 10.0%, 3.0% and 3.0% in 2005, 2006 and 2007, respectively. The range of respiratory symptoms was similar between HBoV-positive and HBoV-negative ARI patients. However, a higher rate of diarrhea was observed in HBoV-positive patients. High HBoV viral loads (> 10(8) copies/mL) and diarrhea were significantly more frequent in patients with exclusive infection by HBoV and in patients with detection of HBoV VP1 mRNA than in patients with viral co-infection, detected in 72.9% of patients with HBoV. In summary, our data demonstrated that active HBoV replication was detected in a small percentage of patients with ARI and was correlated with concurrent diarrhea and lack of other viral co-infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to compare and correlate training impulse (TRIMP) estimates proposed by Banister (TRIMP(Banister)), Stagno (TRIMP(Stagno)) and Manzi (TRIMP(Manzi)). The subjects were submitted to an incremental test on cycle ergometer with heart rate and blood lactate concentration measurements. In the second occasion, they performed 30 min. of exercise at the intensity corresponding to maximal lactate steady state, and TRIMP(Banister), TRIMP(Stagno) and TRIMP(Manzi) were calculated. The mean values of TRIMP(Banister) (56.5 +/- 8.2 u.a.) and TRIMP(Stagno) (51.2 +/- 12.4 u.a.) were not different (P > 0.05) and were highly correlated (r = 0.90). Besides this, they presented a good agreement level, which means low bias and relatively narrow limits of agreement. On the other hand, despite highly correlated (r = 0.93), TRIMP(Stagno) and TRIMP(Manzi) (73.4 +/- 17.6 u.a.) were different (P < 0.05), with low agreement level. The TRIMP(Banister) e TRIMP(Manzi) estimates were not different (P = 0.06) and were highly correlated (r = 0.82), but showed low agreement level. Thus, we concluded that the investigated TRIMP methods are not equivalent. In practical terms, it seems prudent monitor the training process assuming only one of the estimates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Miarka, B, Del Vecchio, FB, and Franchini, E. Acute effects and postactivation potentiation in the special judo fitness test. J Strength Cond Res 25(2): 427-431, 2011-The purpose of this study was to compare the acute short-term effects of (1) plyometric exercise, (2) combined strength and plyometric exercise (contrast), and (3) maximum strength performance in the Special Judo Fitness Test (SJFT). Eight male judo athletes (mean +/- SD, age, 19 +/- 1 years; body mass, 60.4 +/- 5 kg; height, 168.3 +/- 5.4 cm) took part in this study. Four different sessions were completed; each session had 1 type of intervention: (a) SJFT control, (b) plyometric exercises + SJFT, (c) maximum strength + SJFT, and (d) contrast + SJFT. The following variables were quantified: throws performed during series A, B, and C; total number of throws; heart rate immediately and 1 minute after the test; and test index. Significant differences were found in the number of throws during series A: the plyometric exercise (6.4 +/- 0.5 throws) was superior (p < 0.05) to the control condition (5.6 +/- 0.5 throws). Heart rate 1 minute after the SJFT was higher (p < 0.01) during the plyometric exercise (192 +/- 8 bpm) than during the contrast exercise (184 +/- 9 bpm). The contrast exercise (13.58 +/- 0.72) resulted in better index values than the control (14.67 +/- 1.30) and plyometric exercises (14.51 +/- 0.54). Thus, this study suggests that contrast and plyometric exercises performed before the SJFT can result in improvements in the test index and anaerobic power of judo athletes, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A modular superconducting fault current limiter (SFCL) consisting of 16 elements was constructed and tested in a 220 V line for a fault current between 1 kA to 7.4 kA. The elements are made up of second generation (2G) YBCO-coated conductor tapes with stainless steel reinforcement. For each element four tapes were electrically connected in parallel with effective length of 0.4 m per element, totaling 16 elements connected in series. The evaluation of SFCL performance was carried out under DC and AC tests. The DC test was performed through pulsed current tests and its recovery characteristics under load current were analysed by changing the shunt resistor value. The AC test performed using a 3 MVA/220 V/60 Hz transformer has shown the current limiting ratio achieved a factor higher than 10 during fault of up to five cycles without conductor degradation. The measurement of the voltage for each element during the AC test showed that in this modular SFCL the quench is homogeneous and the transition occurs similarly in all the elements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prior experience with the elevated plus maze (EPM) increases the avoidance of rodents to the open arms and impairs the anxiolytic-like effects of benzodiazepines on the traditional behaviors evaluated upon re-exposure to the maze, a phenomenon known as one-trial tolerance. Risk assessment behaviors are also sensitive to benzodiazepines. During re-exposure to the maze, these behaviors reinstate the information-processing initiated during the first experience, and the detection of danger generates stronger open-arm avoidance. The present study investigated whether the benzodiazepine midazolam alters risk assessment behaviors and Fos protein distribution associated with test and retest sessions in the EPM. Naive or maze-experienced Wistar rats received either saline or midazolam (0.5 mg/kg i.p.) and were subjected to the EPM. Midazolam caused the usual effects on exploratory behavior, increasing exploratory activity of naive rats in the open arms and producing no effects on these conventional measures in rats re-exposed to the maze. Risk assessment behaviors, however, were sensitive to the benzodiazepine during both sessions, indicating anxiolytic-like effects of the drug in both conditions. Fos immunohistochemistry showed that midazolam injections were associated with a distinct pattern of action when administered before the test or retest session, and the anterior cingulate cortex, area 1 (Cg1), was the only structure targeted by the benzodiazepine in both situations. Bilateral infusions of midazolam into the Cg1 replicated the behavioral effects of the drug injected systemically, suggesting that this area is critically involved in the anxiolytic-like effects of benzodiazepines, although the behavioral strategy adopted by the animals appears to depend on the previous knowledge of the threatening environment. (C) 2009 IBRO. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Many resource-limited countries rely on clinical and immunological monitoring without routine virological monitoring for human immunodeficiency virus (HIV)-infected children receiving highly active antiretroviral therapy (HAART). We assessed whether HIV load had independent predictive value in the presence of immunological and clinical data for the occurrence of new World Health Organization (WHO) stage 3 or 4 events (hereafter, WHO events) among HIV-infected children receiving HAART in Latin America. Methods. The NISDI (Eunice Kennedy Shriver National Institute of Child Health and Human Development International Site Development Initiative) Pediatric Protocol is an observational cohort study designed to describe HIV-related outcomes among infected children. Eligibility criteria for this analysis included perinatal infection, age ! 15 years, and continuous HAART for >= 6 months. Cox proportional hazards modeling was used to assess time to new WHO events as a function of immunological status, viral load, hemoglobin level, and potential confounding variables; laboratory tests repeated during the study were treated as time-varying predictors. Results. The mean duration of follow-up was 2.5 years; new WHO events occurred in 92 (15.8%) of 584 children. In proportional hazards modeling, most recent viral load 15000 copies/mL was associated with a nearly doubled risk of developing a WHO event (adjusted hazard ratio, 1.81; 95% confidence interval, 1.05-3.11; P = 033), even after adjustment for immunological status defined on the basis of CD4 T lymphocyte value, hemoglobin level, age, and body mass index. Conclusions. Routine virological monitoring using the WHO virological failure threshold of 5000 copies/mL adds independent predictive value to immunological and clinical assessments for identification of children receiving HAART who are at risk for significant HIV-related illness. To provide optimal care, periodic virological monitoring should be considered for all settings that provide HAART to children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: HTLV-2 infections are almost always asymptomatic, and diseases associated with the infection are rarely reported. Little information is available on the relationship between HTLV-2 proviral load and gender or expression of disease, especially among patients with HlV-1 co-infection. Methods: We studied 77 HTLV-2-infected subjects followed in our clinic for the last 9 years; 53 (69%) of them were co-infected with HIV-1. HTLV-2 DNA proviral load (PVL) was measured by real time PCR, a test with a sensitivity of 10 in 10(4) PBMCs. Results: Six of 53 HTLV-2/HIV-1 cases had a myelopathy (all of them had undetectable PVL of HTLV-2). Only 3 of 35 women (2 out of 3 co-infected with HIV) had a detectable PVL, whereas 10 of 42 men had a detectable PVL. Regardless of their HIV status women had significantly lower PVL than men (10 vs. 43 CopieS/10(4) PBMCs, p < 0.05). Conclusions: We noticed the occurrence of myelopathy in HTLV-2/HIV-1 co-infected patients, with undetectable HTLV-2 viral load. There was a sex difference in viral load for HTLV-2, what may be the result in mode of transmission or acquisition of the virus. (c) 2008 Elsevier B. V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.